MODEL
E-2.0
User Guide
7
Our system is designed in Canada and is recognized by most insurers
LED
STATUS
INDICATOR
VALVE STATUS
Sensor 1-20
OK
Fixed
—
Sensor
Interrupted Signal
Flash
Opened
Sensor
Lost Signal
Flash
Closed
Sensor
Water Detection
Fixed
Closed
Sensor
Displaced
Flash slow
Opened
Sensor
Low battery
Flash fast
Opened
Sensor
Critical battery
Fixed
Closed
Sensor
Low Temperature
Flash
Flash
Closed
Batt. / Temp.
Power loss
Flash
Opened
Batt. / Temp.
Low battery
Flash
Opened
Batt. / Temp.
9V - Critical battery
Fixed
Closed
Batt. / Temp.
Low Temperature
Fixed
Closed
Open / Close
Valve opened
Fixed
Opened
Open / Close
Valve closed
Fixed
Closed
Open / Close
Not connected valve
Fixed
—
Open / Close
Valve malfunction
Flash
—
WiFi
Not used
—
WiFi
Connected to Wifi
Fixed
—
WiFi
Lost connection
Fixed
—
Procedure following a water detection alarm
If one of the sensors detects water, the system will close the water inlet valve and audible alarm will sound for 15 minutes.
1.
To stop the audible alarm, press the
Cancel
button on the control panel.
2. Identify which sensor is in alarm (LED light on control panel is red).
3. Identify the source of the water. Dry the sensor and its location. Replace the sensor at its initial location. If the water
is found inside the sensor, replace the sensor.
4. To open the valve again, make sure the sensor is really dry and replaced.
Wait about 2 minutes before pressing the
Reset
button. All LED lights will turn green.