![Water Maze ALPHA-1500 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/water-maze/alpha-1500/alpha-1500_operators-manual_3555614035.webp)
ALPHA SERIES
OPERATOR’S MANUAL
35
ALpha 1500-3100 • #8.913-964.0 • REV. 5/11b
PROBLEM
POSSIBLE CAUSE
SOLUTION
PUMP WON'T START
Tripped breaker
Reset breaker.
Low line voltage
If voltage under recommended minimum,
check size of wiring from main switch
on property. If OK, contact power company.
Defective motor
Replace motor.
Pump filled with mud or debris
Remove pump base and clean
out mud or debris.
PUMP STARTS AND
STOPS TOO OFTEN
Low line voltage
If voltage under recommended minimum,
check size of wiring from main switch on
property. If OK, contact power company.
Long extension cords
Shorten extension cord.
Clogged impeller
Remove housing, unclog.
Faulty motor protector
Replace pump.
Very low head or lift
Increase head or lift.
Back flow of water from
long discharge line
Add check valve as close as
possible to pump (see installation).
Sump pit too small
Increase size of pit.
PUMP WON'T SHUT OFF
Defective float switch
Replace.
PUMP OPERATED
BUT DELIVERS
LITTLE OR
NO WATER
Low line voltage
If voltage under recommended minimum,
check size of wiring from main switch on
property. If OK, contact power company.
Fouled sediment screen
Clean, repair or replace as needed.
Worn or defective pump
parts or plugged impeller
Replace worn parts or entire pump.
Clean parts if required.
Pump air locked
Turn pump "On-Off" several times.
Fill hose manually with water.
Wear plate and impeller worn
Check and replace if needed.
TROUBLESHOOTING
Содержание ALPHA-1500
Страница 39: ......