![Water Maze ALPHA-1500 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/water-maze/alpha-1500/alpha-1500_operators-manual_3555614010.webp)
10
ALPHA SERIES
OPERATOR’S MANUAL
ALpha 1500-3100
•
#8.913-964.0
•
REV. 5/11b
Familiarization With Alpha
The Alpha machine consists of several separate items
which must be installed.
◆
The most obvious component is a stainless steel
separator tank which is the heart of the Alpha. Take
a minute to become familiar with this machine.
◆
Additional items furnished with the Alpha include:
• Perforated sump pump protection/installation
container.
• Sump pump level on/off float control for pump.
• 1-1/2" x 16' (3.81 cm x 4.89 m) recycle hose.
• 1-1/2" (3.81 cm) ball valve for recycle system.
• 1-1/2" x 25' (3.81 cm x 7.62 m) inlet hose with
quick connect (cut to length as needed).
• Drain valve manifold
Leveling Alpha Machine
The Alpha Machine must be set level both side to side
and end to end.
This is important to assure the machine
will give you optimum performance.
Sump Pump/Level Control
◆
Your Alpha comes with a prepackaged perforated
protection container for the sump pump. This con-
tainer is designed to protect the pump from clogging
and damage from debris. There is a level on/off
control attached to the pump which plugs into the
Alpha and then the pump plugs into the float control
on the Alpha only installation.
• Insert the Level Control Float Tree into the strain
relief provided on top of the sump pump container
provided.
• Float tether length must be a minimum of
2" (5.08 cm ) long.
• The turnoff point for the float level control must
be 2" (5.08 cm) above the pump container.
If you have the optional Auto Discharge Kit, refer
to page 20 for proper float location.
• The float must travel its complete arc without:
- Water going over top of pit
- Float touching side walls or bottom
- Float interfering with electrical wiring, plumbing,
bottom or side walls of pit, or any other object.
◆
Lower the sump pump container, with pump and
float attached, into the sump. Check to assure the
float can operate freely.
◆
Connect the pump hose to the inlet of the Alpha.
This is a quick connect camlock fitting; be sure it is
secured.
◆
Plug the float into the electrical outlet on the Alpha
and then plug the power cord for the pump into the
back of the float.
◆
Secure the electrical cords of the pump and the float
to 1-1/2" (3.81 cm) water hose with nylon tie wraps.
Discharge
Connect the 1-1/2" (3.81 cm) discharge line to the male
camlock with the other end into the proper sewer dis-
charge (see Figure 7).
For discharge, close the recycle ball valve. During the
night or on weekends and holidays, open the recycle ball
valve. Add water to the collection pit until the pump starts.
Connect 1-1/2" (3.81 cm) hose to the recycle port on
the Alpha (see Figure 7). The recycle line should be
plumbed back to the collection pit so when the Alpha is
in the recycle mode, the water in all the pits is circulated
to control bacteria.
ORP/pH Controller Option
Install pH/ORP injectors and sensors per drawing on
page 28 or 30. Install sensor into pipe so sensor tip is
half way into pipe, touching fluid, but not touching bot-
tom of pipe. Follow instructions on page 14 to 15 and
instructions that come with controller.
Auto Discharge Option
Tie wrap the N/C and N/O floats to discharge pipe com-
ing off sump pump. Position both floats at the same level
towards the upper part of the pit.
Run float wires to electrical box on Alpha and wire ac-
cording to wire diagrams.
When the water level rises and lifts the floats in the pit,
the electric auto discharge valve rotates to discharge
water. When the water level drops and floats fall, the
electric ball valve rotates and directs water back to the
pits.
Electrical
The machine, when installed, must be electrically
grounded in accordance with local and/or national codes.
Check for proper electrical supply. Plug the cord into a
120V 15 amp electrical outlet. It is recommended that a
Ground Fault Circuit Interrupter be installed in the circuit
breaker for all Wash-Water equipment.
NOTE: Always test all electrical outlets for proper voltage
before plugging in any equipment.