![Water Maze ALPHA-1500 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/water-maze/alpha-1500/alpha-1500_operators-manual_3555614034.webp)
34
ALPHA SERIES
OPERATOR’S MANUAL
ALpha 1500-3100
•
#8.913-964.0
•
REV. 5/11b
PROBLEM
POSSIBLE CAUSE
SOLUTION
NO FLOW OF WATER
INTO ALPHA
Control switch not in "ON" position
Turn switch to "ON" position.
Water in sump not high enough
to activate level switch
Lift float level switch and
see if pump turns on.
Alpha not plugged in
Plug in Alpha.
High level limit switch shut off
Check on/off functioning.
Adjust, repair or replace.
Debris in pump impeller
Unplug pump and remove from container.
Check impeller. Clean/repair.
Flow control valve in "OFF" position
Open valve.
Dirt collection chamber full
Drain and clean.
Dirt lodged in control
valve or check valve
Clean as needed.
Frozen water in lines or valves
Thaw out with warm water.
EXCESSIVE
WATER FLOWING
INTO OIL SKIMMER
Tank not level end to
end or side to side
Level tank.
High level limit switch not functioning
Check ON/OFF functioning.
Adjust, repair or replace.
Water coming into Alpha
faster than machine is rated for
Adjust flow control valve.
Oil sheen filter pack plugged
(Alpha 3100)
Remove and clean.
Discharge line plugged or valve closed Remove obstruction or open valve.
OIL ON TOP OF WATER
IN EXIT CHAMBER
Oil sheen filter pack not firmly
in place (Alpha 3100)
Push down on filter firmly
to lock in place.
Oil sheen filter pack dirty
(Alpha 3100)
Remove and replace/clean media.
TROUBLESHOOTING
Содержание ALPHA-1500
Страница 39: ......
Страница 40: ...Alpha 8 913 964 0 Revised 5 11b Printed in U S A...