WATANABE WPMZ-3 Series Скачать руководство пользователя страница 6

 

 

MODEL WPMZ-3-□□□-□□-□□□                                                                                 

 

6/12 

 

                                                                                                                                                                                                               

IM-0881-04 

 

In Wave Compare mode, settings shown below are active. 

And some settings related to compare output, calculation, hold, level display, trend display, alarm log are inactive. 

 

In Multi Hold mode, settings shown below are active. 

  And some settings related to compare output, calclation, hold, level display, trend display, alarm log are inactive. 

1st Layer 

2nd Layer 

3rd Layer 

(setting items) 

4th Layer (setting values) 

Remarks 

Initial values 

Initial values 

4.System 

General 

MeasureMode 

Default 

Default/MultiHold/WaveCompare 

 

D-ZeroRetention 

Disable 

Disable/Enable 

Whether remember D-Zero value or not. 

Language 

English 

日本語

/English 

Language. 

DisplayDirection 

Horizontal 

Horizontal/Vertical 

Select a direction of screen. 

SettingProtect 

Disable 

Disable/Enable 

 

AdjustProtect 

Disable 

Disable/Enable 

 

DisplayUpdateCycle 

10 times/sec 

1 times/sec,10 times/sec 

 

PatternCopy 

--- 

Go to screen of pattern copy. 

Copy settings of pattern to other pattern. 

AlarmLog 

SyncedAlarm 

AL1

ON

 

AL2

ON 

AL3

ON

 

AL4

ON 

AL1/AL2/AL3/AL4 

 

RecordPos 

BeforeAndAfter 

BeforeAlarm/BeforeAndAfter/AfterAlarm 

 

Overwrite 

Enable 

Disable/Enable 

 

Initialize 

UserDefaultSave 

Save current settings as use initial values. 

 

UserDefaultLoad 

Initialize setting values to user initial values. 

 

FactoryDefautLoad 

Initialize setting values to factoru default. 

 

5.Diag/Log 

InputDiag 

ProcessInputA/B 

 

InputRatingPercent 
InputActualValue 

Check input confirm existence. 
Display percent value or actual value. 

StraingaugeInputA/B 
ExternalCtrl 

 

 

Check ON/OFF of terminal. 

OutputTest 

CompareAL1

AL4 

 

 

Check ON/OFF Level of compare output. 

PulseOutputA/B 

 

 

Check ON/OFF Level of pulse output. 

AnalogOutput 

 

 

Output any value output. 

Step by 10%

 

BCD Output(Data) 

 

 

Output ON/OFF data of each bits. 

BCD Output(PC) 

 

 

Output ON/OFF  by  photo coupler of each 
bits. 

ModbusCom 

 

 

Display received and transmitted data. 

RS-232C Com 

 

 

Display received and transmitted data. 

AlarmLogView 

No. 1

 

Go to screen of log data confirmation. 

 

AlarmLogClear 

--- 

 

Erase all alarm log. 

 

1st Layer 

2nd Layer 

3rd Layer 

(setting items) 

4th Layer (setting values) 

Remarks 

Initial values 

Initial values 

1.Input 

Wave 
Compare A 
 
Wave 
Compare B 

PatternSelect 

Pattern in use 

Pattern 1/2/3/4/5/6/7/8 

Select pattern No. to set. 

StartCondition 

Normal 

Normal/Threshold 

 

Threshold 

+10000 

±99999 

Enable if StartCondition is Threshold. 

ThresholdOnDir 

Excess 

Excess/LessThan 

Enable if StartCondition is Threshold. 

ThresholdTimeout 

00.00 

00.00

99.99[sec] 

Enable if StartCondition is Threshold. 

StartPosition 

-100

+1000[Sampling] 

 

RefWaveCapture 

--- 

Go to RefWaveCapture screen. 

 

CompWavePos 

UpperAndLo
wer 

UpperAndLower/UpperOnly/LowerOnly 

 

CreateCompWave 

UD Shift

:

0

99999[digit] 

LR Shift

:

0

999[Sampling] 

Check→Go to CheckCompWave screen. 

 

AutoScale 

Enable 

Disable/Enable 

 

Scale 

Lower:0 
Upper:10000 

LowerLimit

:

±99999 

UpperLimit

:

±99999 

 

CompleteOutput 

None 

None/AL1/AL2/AL3/AL4 

 

3.Display 

DispSelect 

WaveSelect 

ALL 

WaveA/WaveB 

 

4.System 

WaveLog 

Overwrite 

Enable 

Disanle/Enable 

 

5.Diag.Log 

OK/NG 
WaveA/B 
View 

OK 1

NG 1

 

Go to screen of wave log confirmation. 

 

OK/NG 
WaveA/B 
Erase 

--- 

 

Erase all wave log. 

 

1st Layer 

2nd Layer 

3rd Layer 

(setting items) 

4th Layer (setting values) 

Remarks 

Initial values 

Initial values 

1.Input 

MultiA Base 
MultiB Base 

PatternSelect 

Pattern in use 

Pattern 1/2/3/4/5/6/7/8 

Select pattern No. to set. 

SectionSwitch 

LevelMethod 

LevelMethod/EdgeMethod/EdgeTimer/AutoT
imer 

 

SectionTimerS1

S4 

1.00 

00.01

~

99.99[sec] 

Enable if SectionSwitch is EdgeTimer or 
AutoTimer. 

CompleteOutput 
 

None 

None/AL1/AL2/AL3/AL4 

 

AlarmColorS

1~

S4 

Black 

Black/Red/Yellow/Green 

Select a background color when alarming. 

Scale 

Lower

Upper

10000 

LowerLimit

: 

±99999 

UpperLimit

: 

±99999 

 

TimeAxis 

100ms/div 

100ms/div,1s/div,2s/div,5s/div,10s/div, 
30s/div,60s/div120s/div 

Set time scale of division time. 

MultiA 

S1

S4 

MultiB 

S1

S4 

PatternSelect 

Pattern in use 

Pattern 1/2/3/4/5/6/7/8 

Select pattern No. to set. 

HoldStartCond. 

Normal 

Normal/Threshold/StartDelay 

 

Threshold 

+1000 

±99999 

Enable if HoldStartCond. is Threshold. 

ThresholdOnDir 

Excess 

Excess/LessThan 

Enable if HoldStartCond. is Threshold. 

ThresholdTimeout 

00.00 

00.00

99.99[sec] 

Enable if HoldStartCond. is Threshold. 

Содержание WPMZ-3 Series

Страница 1: ...RTU Input Ach Input Bch GO output GO output 2 Do not wire the power supply line input signal lines and output signal lines near noise sources or relay drive lines 3 Bundling or containing in a same d...

Страница 2: ...ocess input Suitable wire AWG 24 to 16 GO OUT GO GND V HI LO EXC EXC A HI 20 14 15 16 17 18 19 27 21 22 23 24 25 26 connected internally connected internally 22 25 Process input GO output Ach Bch No N...

Страница 3: ...iffelenceHold AVE AveHold Hold mode Indicate hold mode with icon In addition 1ch product shows abbreviation below NORM NormalHold AREA AreaHold 3rd item Displays measured value of 3rd item 2nd item Di...

Страница 4: ...ve 32 None 2 4 8 16 32 64times Set moving average of input Offset 0 Go to screen of setting offset Only process input Fullscale 10000 Go to screen of setting fullscale Only process input ManuAdjust 0...

Страница 5: ...V 10V 1 5V 0 20mA 4 20mA Select a type of output range OutputDispValue None None Ach Bch Calc Select a ch referenced for analog output OutputScale 0 10000 0 99999 100 99999 Scaling of analog output Se...

Страница 6: ...lear Erase all alarm log 1st Layer 2nd Layer 3rd Layer setting items 4th Layer setting values Remarks Initial values Initial values 1 Input Wave Compare A Wave Compare B PatternSelect Pattern in use P...

Страница 7: ...r DispValue manually that you want to display Back to one before by press left arrow key Go to Fullscale display Near 100 calibration Operation is same as Settings are saved by pressing MENU key and b...

Страница 8: ...threshold value to judge How to set the value is shown below The following is an explanation for the compare mode of Level judgement Setting 2 Output CompareAL1 Threshold Set value with arrow keys Pre...

Страница 9: ...and performs same action of DISP key TREND LOG FUNCTION Trend log function is to acquire the alarm log any time by external control It is a function to execute with While data is being acquired the tr...

Страница 10: ...System Initialize UserDefaultSave 1 Setting each values Set all setting values which are needed as user default values 2 Saving user initial values By executing to save user default values current set...

Страница 11: ...etween Power terminals and inputs external controls comparative outputs other outputs AC1500V for 1 minute AC power and DC power Between input terminals and external controls comparative outputs other...

Страница 12: ...upper limit or lower limit value AL3 Display value AL4 upper limit or lower limit value AL4 Difference judgement mode When the maximum minimum during the fixed time exceeds the judgement value alarm...

Отзывы: