10.  Configuring your WWS800/850 

 
The configuration of WWS800/850 Scanner is done by reading the setup labels 
contained in the Configuration Manual (the second part of this manual). This 
section describes the procedure of configuring the scanner. Some configuration 
examples are also given in this section for illustration. 

10.1  Enter Configuration Mode 

 
To start the configuration, the “

Enter Setup

” label must be read. This will put the 

scanner in the configuration mode. The scanner will respond with 6 beeps and the 
indicator will turn blue after the label is read. This “Enter Setup” label is located at 
the bottom of almost every even page of the Configuration Manual. 

10.2 Default 

 
All the parameters of the scanner will return to their default values by reading the 
“Default” label. The scanner will beep twice when the “Default” label is read. 

10.3 List Setting 

 
The current setting of all scanner parameters can be sent to the host computer for 
user inspection. The listing is separated into ten pages. User can select the page of 
interest by reading the “Page x” label 

Page 1: Interface, Buzzer, and Scanner Parameters 
Page 2: Prefix, Postfix, and Length Code Setting 
Page 3: Code ID 
Page 4: Readable Symbologies 
Page 5: Symbology Parameters (1/3) 
Page 6: Symbology Parameters (2/3) 
Page 7: Symbology Parameters (3/3) 
Page 8: Editing Format 1 
Page 9: Editing Format 2 
Page 10: Editing Format 3 
 
 
 

 

36

10.4  Setting Parameter Values 

 
For most of the parameters, only one read is required to set them to new values. 
The scanner will respond with two beeps when these parameters are configured. 
But for some special parameters, multiple reads are required to complete the 
setting. The scanner will respond with a short beep if the configuration of the 
parameter is still not complete. These parameters usually refer to a numeric value 
or a string of characters, such as keyboard type, inter-character delay, prefix / 
postfix code, etc..  

For these kinds of parameters, the label of the parameter to be configured must be 
read first. Then the labels comprising the numeric value or character string are 
read. Finally, the “Validate” label must be read to complete the setting. The 
scanner will respond with two beeps when the “Validate” label is read. 

10.4.1 Numeric Parameters 

The configuration procedures for numeric parameters are shown below. 

Parameter Label

Decimal Label

"Validate" Label

 

For example, to configure the Inter-Character Delay to be 15 ms, the “Inter-
Character Delay” label is first read, and then the decimal digit labels “1” and “5”, 
and finally, the “Validate” label to complete the setting. 

10.4.2  Character String Parameters 

Basically, each character of a string is programmed by two hexadecimal digits, 
which usually comprise a value that is the ASCII code equivalence of the character 
being programmed. 

Beside the two hexadecimal digits, there is an optional key type/status can also be 
specified for each character of the string parameters. This optional key type/status 
can only be specified for some particular parameters when keyboard interface is 

Содержание WWS800

Страница 1: ...pment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If applica...

Страница 2: ...1 Transmit Buffer Setting 13 4 4 2 Memory Mode 13 4 4 3 Clear Data 13 4 4 4 Send Data 13 4 4 5 Memory Data Delay 13 5 BLUETOOTH SERIAL PORT 14 5 1 CONFIGURING WWS800 850 14 5 1 1 Activate Bluetooth S...

Страница 3: ...O FIELDS 32 9 6 ADDITIONAL FIELDS 33 9 7 FIELD TRANSMISSION SEQUENCE 33 9 8 END OF FORMAT PROGRAMMING 33 9 9 ACTIVATE DATA EDITING FORMATS 33 9 10 EXCLUSIVE DATA EDITING 34 9 11 PROGRAMMING EXAMPLES 3...

Страница 4: ...n be reorganized according to user programmable formats Up to three data editing formats are supported Extremely Low Power Consumption 2 2 Base Installation The WWS800 850 kit contains A WWS800 850 wi...

Страница 5: ...abel the scanner will beep once then scan the SERIAL number barcode The scanner will beep twice low then high When it establishes RF connection with the base the scanner will then emit three short asc...

Страница 6: ...eep The scanner will issue a long beep with a low tone to indicate errors Enter Exit Configuration Beep The scanner will issue 6 beeps upon entering exiting the configuration mode Setup Beep In config...

Страница 7: ...the scanner to start scanning once a barcode is brought within Range of the scanner This will activate the LEDs and the scanner will start decoding the barcode The auto sense mode works only under Au...

Страница 8: ...below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PS2 30 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboa...

Страница 9: ...RS232 Interface User can select the desired flow control baud rate parity and data bits to be used in this output interface 4 2 1 Baud Rate Parity Data Bits The supported baud rate parity and data bit...

Страница 10: ...section illustrates a step by step installation and configuration procedures of the WWS800 850 for Bluetooth Serial Port Bluetooth transceivers dongles always come with their own driver or Windows XP...

Страница 11: ...e unit however a charging dock is still needed for charging the 800 850 battery This section illustrates a step by step installation and configuration procedures of the 800 850 for Bluetooth HID Bluet...

Страница 12: ...e scanner will make necessary adjustment when sending the A Q W Z Y and M character according to this setting 6 2 3 Keyboard Style Digits There are two digit layout styles as shown on the following fi...

Страница 13: ...ections 6 3 1 Windows XP with Service Pack2 1 Insert the Bluetooth dongle into PC host 2 Double click the Bluetooth icon on the lower right of the taskbar 3 Click Add button 1 Check My device is set u...

Страница 14: ...comm Bluetooth Driver 1 Click icon at PC 2 Click Find Bluetooth Devices icon at My Bluetooth Places 22 3 Right click the 800 850 scanner and select Pair Device 4 Input PIN code and click OK button 5 R...

Страница 15: ...g transmitted 7 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always performed when decoding these...

Страница 16: ...ng Because of the way system number 1 is encoded if both system numbers are enabled user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this param...

Страница 17: ...selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 7 10 Plessey Convert to UK Plessey If this...

Страница 18: ...ngth Code or any Additional Field and is performed before editing mode processing If only the character to be replaced is specified every occurrence of that character in the barcode will be taken away...

Страница 19: ...not be performed unless all three applicable conditions are met The configurable applicable conditions are described below Code Type This parameter specifies the code type of the data eligible for da...

Страница 20: ...n the Editing Format Parameters section of the configuration manual 9 9 Activate Data Editing Formats Before data can be processed by a particular editing format that format must be enabled The editin...

Страница 21: ...or most of the parameters only one read is required to set them to new values The scanner will respond with two beeps when these parameters are configured But for some special parameters multiple read...

Страница 22: ...are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed 38 Add Control L The left Control key will be sent together with t...

Отзывы: