background image

 

33

always included in the field. User though, has the option of discarding this 
terminating string. 

• 

Field Length

: The field division can be simply specified by the field length. 

The scanner will assign the next specified number of characters into the 
field. 

9.6 Additional Fields 

 
User can create up to five additional fields for each editing format. Each additional 
field can have at most four characters. The additional fields are numbered AF1 to 
AF5 accordingly. 

9.7  Field Transmission Sequence 

 
After the data fields and the additional fields are configured, user can now program 
the transmission sequence of these fields that comprise the final data. The “Start” 
label must be read before assigning the field transmission sequence. And then the 
desired field transmission sequence can be specified. The scanner will transmit the 
fields in the order (sequence) user programmed when sending data. The field 
transmission sequence can be assigned in any desired order and fields can also be 
assigned multiple times. The maximum number of fields can be assigned is twelve. 
After the sequence has been assigned, the “End” label must be read to complete the 
setting. 

9.8  End of Format Programming 

 
After all the desired parameters are configured, the “End of Format Programming” 
label must be read to conclude the programming of the editing format. This label is 
located at the bottom of every even page in the “Editing Format Parameters” 
section of the configuration manual. 

9.9  Activate Data Editing Formats 

 
Before data can be processed by a particular editing format, that format must be 
enabled. The editing formats can be enabled or disabled individually. 
 
 
 

 

34

9.10  Exclusive Data Editing 

 
If this parameter is enabled, all data read by the scanner must be processed by the 
editing format. If the data is not eligible for all enabled editing formats, the scanner 
will not accept the reading and the data will not be transmitted. 

9.11 Programming Examples 

 

Example 1:

 Extracts data from the 10th character to the 19th character. 

Total Number of Fields: 3 
Field 1: Divide field by field length, set field length to 9 
Field 2: Divide field by field length, set field length to 10 
Field Transmission Sequence: F2 

Example 2:

 Extract the date code, item number, and quantity information from 

barcodes. Data is encoded in the barcode like this: From the first character to the 
6th character is the date code. From the 7th character is the item number, its 
length is not fixed but is delimited by a ‘-’ character. After the ‘-’ character is the 
quantity information. 

Data should be transmitted like this: Item number goes first, then a TAB character, 
and then the date code, and then another TAB character and finally the quantity. 

Total Number of Fields: 3 
 
Field 1: Divide fields by field length and set the field length to 6. 
Field 2: Divide fields by field terminating string. Set terminating string to ‘-’, 

and discard the terminating string. 

Additional Field 1: Set to one TAB character. 
Field Transmission Sequence:  

F2   AF1   F1   AF1   F3 
 

Содержание WWS800

Страница 1: ...pment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If applica...

Страница 2: ...1 Transmit Buffer Setting 13 4 4 2 Memory Mode 13 4 4 3 Clear Data 13 4 4 4 Send Data 13 4 4 5 Memory Data Delay 13 5 BLUETOOTH SERIAL PORT 14 5 1 CONFIGURING WWS800 850 14 5 1 1 Activate Bluetooth S...

Страница 3: ...O FIELDS 32 9 6 ADDITIONAL FIELDS 33 9 7 FIELD TRANSMISSION SEQUENCE 33 9 8 END OF FORMAT PROGRAMMING 33 9 9 ACTIVATE DATA EDITING FORMATS 33 9 10 EXCLUSIVE DATA EDITING 34 9 11 PROGRAMMING EXAMPLES 3...

Страница 4: ...n be reorganized according to user programmable formats Up to three data editing formats are supported Extremely Low Power Consumption 2 2 Base Installation The WWS800 850 kit contains A WWS800 850 wi...

Страница 5: ...abel the scanner will beep once then scan the SERIAL number barcode The scanner will beep twice low then high When it establishes RF connection with the base the scanner will then emit three short asc...

Страница 6: ...eep The scanner will issue a long beep with a low tone to indicate errors Enter Exit Configuration Beep The scanner will issue 6 beeps upon entering exiting the configuration mode Setup Beep In config...

Страница 7: ...the scanner to start scanning once a barcode is brought within Range of the scanner This will activate the LEDs and the scanner will start decoding the barcode The auto sense mode works only under Au...

Страница 8: ...below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PS2 30 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboa...

Страница 9: ...RS232 Interface User can select the desired flow control baud rate parity and data bits to be used in this output interface 4 2 1 Baud Rate Parity Data Bits The supported baud rate parity and data bit...

Страница 10: ...section illustrates a step by step installation and configuration procedures of the WWS800 850 for Bluetooth Serial Port Bluetooth transceivers dongles always come with their own driver or Windows XP...

Страница 11: ...e unit however a charging dock is still needed for charging the 800 850 battery This section illustrates a step by step installation and configuration procedures of the 800 850 for Bluetooth HID Bluet...

Страница 12: ...e scanner will make necessary adjustment when sending the A Q W Z Y and M character according to this setting 6 2 3 Keyboard Style Digits There are two digit layout styles as shown on the following fi...

Страница 13: ...ections 6 3 1 Windows XP with Service Pack2 1 Insert the Bluetooth dongle into PC host 2 Double click the Bluetooth icon on the lower right of the taskbar 3 Click Add button 1 Check My device is set u...

Страница 14: ...comm Bluetooth Driver 1 Click icon at PC 2 Click Find Bluetooth Devices icon at My Bluetooth Places 22 3 Right click the 800 850 scanner and select Pair Device 4 Input PIN code and click OK button 5 R...

Страница 15: ...g transmitted 7 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always performed when decoding these...

Страница 16: ...ng Because of the way system number 1 is encoded if both system numbers are enabled user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this param...

Страница 17: ...selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 7 10 Plessey Convert to UK Plessey If this...

Страница 18: ...ngth Code or any Additional Field and is performed before editing mode processing If only the character to be replaced is specified every occurrence of that character in the barcode will be taken away...

Страница 19: ...not be performed unless all three applicable conditions are met The configurable applicable conditions are described below Code Type This parameter specifies the code type of the data eligible for da...

Страница 20: ...n the Editing Format Parameters section of the configuration manual 9 9 Activate Data Editing Formats Before data can be processed by a particular editing format that format must be enabled The editin...

Страница 21: ...or most of the parameters only one read is required to set them to new values The scanner will respond with two beeps when these parameters are configured But for some special parameters multiple read...

Страница 22: ...are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed 38 Add Control L The left Control key will be sent together with t...

Отзывы: