background image

Wasp WWS650

2D Handheld Wireless Barcode Reader 

Product Reference Guide

Содержание WWS650

Страница 1: ...Wasp WWS650 2D Handheld Wireless Barcode Reader Product Reference Guide...

Страница 2: ...on appropriate media If you visit our website and would like to make comments or sugges tions about this or other Wasp Technologies publications please let us know via the Con tact WaspTechnologies pa...

Страница 3: ...Linking a BT Reader to a PC 14 Interface Selection 16 Setting the Interface 16 Customizing Configuration Settings 19 Configure Interface Settings 19 Global Interface Features 19 Configuring Other Fea...

Страница 4: ...it 63 Case Conversion 63 Character Conversion 64 Reading Parameters 65 Double Read Timeout 66 LED AND BEEPER INDICATORS 68 Power On Alert 68 Good Read When to Indicate 68 Good Read Beep Type 69 Good R...

Страница 5: ...eck Character Transmission 97 Expand EAN 8 to EAN 13 98 EAN 8 2D Component 98 UPC EAN GLOBAL SETTINGS 99 UPC EAN Price Weight Check 99 UPC EAN Quiet Zones 100 ADD ONS 101 Optional Add ons 101 Optional...

Страница 6: ...D 2 OF 5 CIP HR 132 Interleaved 2 of 5 CIP HR Enable Disable 132 FOLLETT 2 OF 5 132 Follett 2 of 5 Enable Disable 132 STANDARD 2 OF 5 133 Standard 2 of 5 Enable Disable 133 Standard 2 of 5 Check Chara...

Страница 7: ...h 2 160 GS1 DATABAR LIMITED 161 GS1 DataBar Limited Enable Disable 161 GS1 DataBar Limited GS1 128 Emulation 161 GS1 DataBar Limited 2D Component 162 CODE 93 162 Code 93 Enable Disable 162 Code 93 Che...

Страница 8: ...17 Code 128 GS1 128 Emulation 195 Micro PDF417 Length Control 196 Micro PDF417 Set Length 1 196 Micro PDF417 Set Length 2 197 QR Code 198 QR Code Enable Disable 198 QR Code Length Control 198 QR Code...

Страница 9: ...rol 232 REFERENCES 233 RS 232 Parameters 234 RS 232 234 RS 232 USB COM Parameters 235 Keyboard Interface 242 Wedge Quiet Interval 242 Intercharacter Delay 243 Intercode Delay 244 Symbologies 245 Set L...

Страница 10: ...S 295 Control Character Emulation 295 Single Press and Release Keys 295 Interface Type PC AT PS 2 USB Keyboard or USB Keyboard for APPLE 296 Interface type PC AT PS 2 Alt Mode or USB Keyboard Alt Mode...

Страница 11: ...reader There are different sections for interface types general features data formatting symbology specific and model specific features Chapter 4 Message Formatting gives background information and de...

Страница 12: ...ring and operating the reader CAUTION The CAUTION symbol advises you of actions that could damage equipment or property Current versions of this Product Reference Guide PRG Quick Reference Guide QRG a...

Страница 13: ...nning activities It consists of a soft dark red illumination combined with two blue LED triangles pointing at the targeted bar code The result is a precise aiming system which contributes to low eye f...

Страница 14: ...gramming labels like Restore Custom Defaults on page 20 require only the scan of the single label to enact the change Most however require the reader to be placed in Pro gramming Mode prior to scannin...

Страница 15: ...1 Base LEDs Red LED Green LED Yellow LED LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On Battery charging...

Страница 16: ...may damage the battery or reduce its life expectancy If the device causes an abnormal current to flow it may cause the battery to become hot explode or ignite and cause serious injury Lithium ion batt...

Страница 17: ...s separately from the device in compliance with European Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subsequent modifica tions US and China regulatory and others laws and regulations...

Страница 18: ...ck will rise slightly in the rear pushed by the contact springs 2 Extract the battery pack by slightly rotating the pack and pulling away from the reader To mount the new battery pack reverse the proc...

Страница 19: ...t should be returned in its original shipping container Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host 1 Begin by Con...

Страница 20: ...on the cable s jack for all configurations For all interfaces except RS 232 a power supply is recommended but not necessary because the base can be powered from the Host When the base is powered from...

Страница 21: ...Securely plug the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Station Cable Stopper Power Cable I F Cable 3 After the cables are plugged in...

Страница 22: ...to the host device as shown in Figure 3 Keyboard Wedge interface cables have a Y connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the key...

Страница 23: ...Power down the host system 2 Connect the appropriate interface cable into the Base as shown 3 Place the reader in the Base 4 Power up the host The reader will link to the Base 5 When the host complet...

Страница 24: ...tion was discovered Two green LED flashes after this tone indicates that more than one Base Station was discovered and the reader did not link Three LED flashes after this tone indicate a security err...

Страница 25: ...th address 4 Scan the link label you created in step 3 Linking to a PC in HID mode 1 Install any drivers provided with the Bluetooth adapter 2 Scan the Link to PC in HID label below 3 Use the host com...

Страница 26: ...TE Unlike some programming features and options interface selections require that you scan only one programming bar code label DO NOT scan an ENTER EXIT bar code prior to scanning an interface selecti...

Страница 27: ...es starting on page 37 AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding P HA29 P CR Select KBD AT P HA11 P CR Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encodi...

Страница 28: ...lect KBD IBM M Set KEYBOARD WEDGE Interface Features starting on page 37 P HA16 P CR Select KBD IBM MB Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Keyboard Wedge for DIGIT...

Страница 29: ...ing sections of this manual allow configuration of non interface specific settings you might require Data Format Data Format offers options to control the messages sent to the Host system Reading Para...

Страница 30: ...estore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below Both labels restore the scanner configuration to the factory settings including the interface type CAUT...

Страница 31: ...Configuration RS 232 USB Com Interfaces on page 30 Keyboard Settings on page 37 Parameters common to all interface applications Data Format on page 51 gives options to control the messages sent to the...

Страница 32: ...g You can then start again at the beginning 4 Complete the programming sequence by scanning the ENTER EXIT PROGRAMMING bar code to exit Programming Mode For more detailed descriptions programming info...

Страница 33: ...When set to ignore the reader will ignore all host commands except for those necessary for service mode flash programming mode keeping the interface active transmission of labels DEFAULT CIFIH00 CR Ho...

Страница 34: ...Enter Exit Programming Mode Global Interface Features 24 Wasp WWS650 NOTES...

Страница 35: ...ming bar codes in this section if modifications to the standard RS 232 inter face settings are necessary to meet your system s requirements Additional settings which apply to both the RS 232 and USB i...

Страница 36: ...234 for information on this feature CR2BA00 CR Baud Rate 1200 CR2BA01 CR Baud Rate 2400 CR2BA02 CR Baud Rate 4800 CR2BA03 CR Baud Rate 9600 DEFAULT CR2BA04 CR Baud Rate 19 200 CR2BA05 CR Baud Rate 38...

Страница 37: ...rface with devices requiring a 7 bit or 8 bit ASCII pro tocol for sending and receiving data CR2DA00 CR 7 Data Bits CR2DA01 CR 8 Data Bits DEFAULT Stop Bits Set the number of stop bits to match host d...

Страница 38: ...rity This feature specifies parity required for sending and receiving data Select the parity type according to host device requirements See page 234 for more information DEFAULT CR2PA00 CR Parity None...

Страница 39: ...g Control DEFAULT CR2HC00 CR Handshaking Control RTS CR2HC01 CR Handshaking Control RTS CTS CR2HC02 CR Handshaking Control RTS XON XOFF CR2HC03 CR Handshaking Control RTS On CTS CR2HC04 CR Handshaking...

Страница 40: ...RACTER on page 33 ACK NAK TIMEOUT VALUE on page 34 ACK NAK RETRY COUNT on page 34 ACK NAK ERROR HANDLING on page 35 INDICATE TRANSMISSION FAILURE on page 35 DISABLE CHARACTER on page 36 ENABLE CHARACT...

Страница 41: ...R EXIT PROGRAM MING MODE bar code above then the bar code at left fol lowed by the digits from the Alphanumeric characters in Appendix D Keypad representing your desired char acter s End by scanning t...

Страница 42: ...LT CBPNF01 CR Beep On Not On File Enable ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 236 for more information DEFAULT CR2AE00 CR ACK...

Страница 43: ...icts with normal operation of these characters 8 bit data is not recognized when the option Data Bits on page 27 has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or...

Страница 44: ...the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count This feature specifies the nu...

Страница 45: ...rror Handling Ignore Errors Detected CR2EH01 CR ACK NAK Error Handling Process Error as Valid ACK Character CR2EH02 CR ACK NAK Error Handling Process Error as Valid NAK Character Indicate Transmission...

Страница 46: ...more information on setting this feature CR2DC Select Disable Character Setting DEFAULT 0x44 Disable Character is D Enable Character Specifies the value of the RS 232 host command used to enable the r...

Страница 47: ...MLOCK on page 44 USB KEYBOARD SPEED on page 45 USB KEYBOARD NUMERIC KEYPAD on page 46 Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces Reference Ap...

Страница 48: ...CKBCO01 CR Country Mode Belgium CKBCO02 CR Country Mode Britain CKBCO11 CR Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces...

Страница 49: ...the Country Mode feature description CKBCO13 CR Country Mode French Canadian CKBCO05 CR Country Mode Germany Supports only the interfaces listed in the Country Mode feature description CKBCO0D CR Cou...

Страница 50: ...ountry Mode Poland Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces listed in the Country Mode feature description CKBCO08 CR Country Mode Portu...

Страница 51: ...amming Mode Product Reference Guide 41 Country Mode continued CKBCO09 CR Country Mode Spain KBCO0A CR Country Mode Sweden CKBCO0B CR Country Mode Switzerland Supports only the interfaces listed in the...

Страница 52: ...rol character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Shift special keys are located from 0x80 to 0xA1 C...

Страница 53: ...NTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 0A Quiet Interval is 100 milliseconds I...

Страница 54: ...lternate key encoding keyboard is selected DEFAULT CKBCL00 CR Caps Lock State Caps Lock OFF CKBCL01 CR Caps Lock State Caps Lock ON CKBCL02 CR Caps Lock State AUTO Caps Lock Enable Numlock This option...

Страница 55: ...s the USB poll rate for a USB keyboard NOTE DEFAULT CKBSP01 CR USB Keyboard Speed 1ms CKBSP02 CR USB Keyboard Speed 2ms CKBSP03 CR USB Keyboard Speed 3ms CKBSP04 CR USB Keyboard Speed 4ms CKBSP05 CR U...

Страница 56: ...ms CKBSP0A CR USB Keyboard Speed 10ms Enter Exit Programming Mode 46 Wasp WWS650 USB Keyboard Speed continued USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent u...

Страница 57: ...or USB interfaces differ depending upon which host type the reader will be connected with Use the feature settings in this chapter to specifically configure for the USB OEM interface Other USB interfa...

Страница 58: ...all devices to communicate Options are Table Top Scanner Handheld Scanner NOTE CIBUT00 CR USB OEM Device Usage Table Top Scanner CIBUT01 CR USB OEM Device Usage Handheld Scanner DEFAULT It may be nec...

Страница 59: ...ot con verted to Code 39 or verified to be valid for Code 39 Options are IBM Standard Format Send labels in standard IBM format Mixed IBM Standard and Code 39 Format Code 39 Format Translate the follo...

Страница 60: ...ng Mode 50 Wasp WWS650 Interface Options DEFAULT CIFO101 CR Obey Scanner Configuration Host Commands CIFO102 CR Ignore Scanner Configuration Host Commands This feature provides for an interface specif...

Страница 61: ...l ID Symbology Selection 1D Symbolo gies on page 58 Label ID Symbology Selection 2D Symbolo gies on page 62 CASE CONVERSION starting on page 63 CHARACTER CONVERSION starting on page 64 CAUTION It is n...

Страница 62: ...EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix bar code fol lowed by the digits in hex from the Alphanumeric characters in...

Страница 63: ...el identifiers consist of three characters as follows A close brace character ASCII followed by A code character see some samples in the table below followed by A modifier character the modifier chara...

Страница 64: ...IX d 64 EAN128 C 43 EAN128 COMPOSITE C 43 EAN13 E 45 EAN13 P2 E 45 EAN13 P5 E 45 EAN13 COMPOSITE E 45 EAN8 E 45 EAN8 P2 E 45 EAN8 P5 E 45 EAN8 COMPOSITE E 45 FOLLET 2OF5 X 58 I2OF5 I 49 IATA INDUSTRIA...

Страница 65: ...ctions on setting this feature CU8AI00 CR Set AIM ID Individually for GS1 128 Disable CU8AI01 CR Set AIM ID Individually for GS1 128 Enable DEFAULT POSTAL IMB X 58 POSTAL JAPANESE X 58 POSTAL KIX X 58...

Страница 66: ...der to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 53 See Label ID starting on page 249 of References for more informati...

Страница 67: ...ing on page 58 to select the symbology you want to set followed by up to 3 characters from the ASCII Chart at the back of this manual See Label ID Set Individually Per Symbology on page 252 for detail...

Страница 68: ...et ABC Codabar Label ID Character s CP3ID Set Code 32 Pharmacode Label ID Character s CALID Set Anker Plessey Label ID Character s CC9ID Set Code 93 Label ID Character s CPAID Set Australian Postal Co...

Страница 69: ...site Label ID Character s CU8ID Set GS1 128 Label ID Character s C82ID Set EAN 8 P2 Label ID Character s CUMID Set GS1 128 Composite Label ID Character s C85ID Set EAN 8 P5 Label ID Character s CLBID...

Страница 70: ...Code Label ID Character s CMSID Set MSI Label ID Character s CU2ID Set Industrial 2 of 5 Label ID Character s CPPID Set Planet Postal Code Label ID Character s CI2ID Set Interleaved 2 of 5 Label ID C...

Страница 71: ...haracter s CPRID Set Royal Postal Code Label ID Character s CA2ID Set UPC A P2 Label ID Character s CS2ID Set Standard 2 of 5 Label ID Character s CA5ID Set UPC A P5 Label ID Character s CPSID Set Swe...

Страница 72: ...ID Character s CP4ID Set PDF 417 Label ID Character s CDMID Set Data Matrix Label ID Character s CMIID Set Micro PDF 417 Label ID Character s CMQID Set Micro QR Label ID Character s CQRID Set QR Code...

Страница 73: ...information Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case NOTE DEFAULT CLFCA00 CR Case Conversion Disable no case conversion CLFCA01 CR...

Страница 74: ...e pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in a pair is FF then no conversion is done NOTE CLFCH Configu...

Страница 75: ...ion on page 74 Stand Operation on page 75 Pick Mode on page 76 Stand Mode Sensitivity on page 76 Stand Mode Illumination Off Time on page 77 Scanning Active Time on page 77 Stand Illumination Control...

Страница 76: ...l again within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label read CSNDR0A CR Double Read Timeout 0 1 Seco...

Страница 77: ...ters Enter Exit Programming Mode Product Reference Guide 67 Double Read Timeout continued CSNDR50 CR Double Read Timeout 0 8 Second CSNDR5A CR Double Read Timeout 0 9 Second CSNDR64 CR Double Read Tim...

Страница 78: ...er On Alert Disable No Audible Indication CBPPU01 CR Power On Alert Power up Beep DEFAULT Good Read When to Indicate This feature specifies when the reader will provide indication beep and or flash it...

Страница 79: ...PTY00 CR Good Read Beep Type Mono CBPTY01 CR Good Read Beep Type Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the l...

Страница 80: ...Length 60 msec CBPLE08 CR Good Read Beep Length 80 msec DEFAULT CBPLE0A CR Good Read Beep Length 100 msec CBPLE0C CR Good Read Beep Length 120 msec CBPLE0E CR Good Read Beep Length 140 msec CBPLE10 C...

Страница 81: ...Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels CBPVO00CR Good Read Beep Volume Beeper Off CBPVO01CR Good Read Beep Volume Low CBPVO...

Страница 82: ...and examples for setting this feature CLAGL00 CR Good Read LED Duration Setting Keep LED on until next trigger pull CLAGL Select Good Read LED Duration Setting To configure this feature scan the ENTER...

Страница 83: ...6 in References for descriptions CSNRM00 CR Scan Mode Trigger Single DEFAULT CSNRM01 CR Scan Mode Trigger Hold Multiple CSNRM02 CR Scan Mode Trigger Pulse Multiple CSN Scan Mode Flashing CSNRM04 CR Sc...

Страница 84: ...f enabled the blue indicator will blink when Stand Mode scanning is active If the reader is removed from its Stand support or from the Base Station cordless models and switches out of Stand Mode into...

Страница 85: ...ase station cordless models only Below are further options concerning Stand Operation Ignore Autorecognition Disables mode switching when the reader is placed in a stand Change to Stand Mode Automatic...

Страница 86: ...s when they are placed close together such as on a pick sheet NOTE This feature is not compatible with Multiple Labels Reading in a Volume DEFAULT CSNPM00 CR Pick Mode Disable CSNPM01 CR Pick Mode Ena...

Страница 87: ...GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing your desired character s End by scanning the ENTER EX...

Страница 88: ...lectable range is 100 to 9 900 milliseconds 0 1 to 9 9 seconds in 100 millisecond increments See page 260 in References for detailed information on setting this feature CSNFN Select Flash ON Time Sett...

Страница 89: ...g To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing yo...

Страница 90: ...erences for a description of this feature DEFAULT LSTM00 Aiming Off After Decoding LSTM Set Aiming Duration Timer To configure scan the ENTER EXIT PROGRAMMING MODE bar code above then the bar code at...

Страница 91: ...Off CLSSP01 CR Green Spot Duration Short 300 msec DEFAULT CLSSP02 CR Green Spot Duration Medium 500 msec CLSSP03 CR Green Spot Duration Long 800 msec Mobile Phone Mode This mode is useful for scannin...

Страница 92: ...ls in this man ual Scan the Disable bar code below to return the scanner to its default for this feature To set decoding for only 2D codes go to 2D Normal Inverse Symbol Control on page 179 For addi t...

Страница 93: ...iple Reading Mode is enabled the scanner keeps on processing the image until all the labels present are decoded The reader then sorts the data from all the bar codes if config ured to do so before tra...

Страница 94: ...E bar code above then the bar code at left followed by the digits From the alphanumeric char acters In Appendix d keypad representing your desired Character s end by scanning the enter exit bar code a...

Страница 95: ...page 162 Code 39 PZN page 117 MSI page 167 Code 128 page 118 Plessey page 172 Default settings are indicated at each feature option with a green arrow Also reference Appendix B Standard Defaults for...

Страница 96: ...eature to disable all symbologies 1 Scan the ENTER EXIT PROGRAMMING Mode bar code 2 Scan the Disable All Symbologies bar code 3 Complete the programming sequence by scanning the ENTER EXIT PROGRAMMING...

Страница 97: ...Control This feature is used to control the reader s method of processing coupon labels CCPLC00 CR Coupon Control Allow all coupon bar codes to be decoded CCPLC01 CR Coupon Control Enable only UPCA c...

Страница 98: ...disabled the reader will not read UPC A bar codes CABEN00 CR UPC A Disable CABEN01 CR UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character along w...

Страница 99: ...the sym bology ID to match those required for EAN 13 DEFAULT CAB3B00 CR UPC A to EAN 13 Don t Expand CAB3B01 CR UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables...

Страница 100: ...e label of this symbology is decoded DEFAULT CAB2D00 CR EAN 13 2D Component Disable 2D component not required CAB2D01 CR EAN 13 2D Component 2D component must be decoded UPC E The following options ap...

Страница 101: ...T00 CR UPC E Check Character Transmission Don t Send CEBCT01 CR UPC E Check Character Transmission Send DEFAULT UPC E 2D Component This feature enables disables a requirement that a 2D label component...

Страница 102: ...Selecting this feature also changes the sym bology ID to match those required for EAN 13 DEFAULT CEB3B00 CR UPC E to EAN 13 Don t Expand CEB3B01 CR UPC E to EAN 13 Expand Expand UPC E to UPC A Expands...

Страница 103: ...ransmit CEBNS01 CR UPC E Number System Character Transmit DEFAULT GTIN FORMATTING This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character fo...

Страница 104: ...n disabled the reader will not read EAN 13 JAN 13 bar codes C3BEN00 CR EAN 13 Disable C3BEN01 CR EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check char...

Страница 105: ...character is the first character of the label C3BF100 CR EAN 13 Flag 1 Char Don t transmit C3BF101 CR EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion...

Страница 106: ...symbology is decoded DEFAULT C3B2D00 CR EAN 13 2D Component Disable 2D component not required C3B2D01 CR EAN 13 2D Component 2D component must be decoded ISSN The following options apply to the ISSN...

Страница 107: ...able When disabled the reader will not read EAN 8 JAN 8 bar codes C8BEN00 CR EAN 8 Disable C8BEN01 CR EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check c...

Страница 108: ...00 CR Expand EAN 8 to EAN 13 Disable C8B3B01 CR Expand EAN 8 to EAN 13 Enable EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label for...

Страница 109: ...r each feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT CPWEN00 CR Price Weight Check Disabled CPWEN01 CR...

Страница 110: ...uiet zones for UPC EAN labels Quiet zones are blank areas at the ends of a bar code typically 10 times the width of the narrowest bar or space in the label The property applies to all EAN UPC symbolog...

Страница 111: ...l Add Ons Enable P2 DEFAULT CADO500 CR Optional Add Ons Disable P5 CADO501 CR Optional Add Ons Enable P5 Cordless models only DEFAULT CADO800 CR Optional Add Ons Disable GS1 128 CADO801 CR Optional Ad...

Страница 112: ...r an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 105 CADOT01 CR Optional Add on Timer 10ms CADOT02 CR Optional Add on T...

Страница 113: ...70ms DEFAULT CADOT0A CR Optional Add on Timer 100ms CADOT0C CR Optional Add on Timer 120ms CADOT0E CR Optional Add on Timer 140ms CADOT10 CR Optional Add on Timer 160ms 1D Symbologies Enter Exit Progr...

Страница 114: ...CADOT16 CR Optional Add on Timer 220ms CADOT18 CR Optional Add on Timer 240ms CADOT1A CR Optional Add on Timer 260ms CADOT1C CR Optional Add on Timer 280ms CADOT1E CR Optional Add on Timer 300ms Enter...

Страница 115: ...ar EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 102 DEFAULT CADUT00 CR Optional GS1 128 Add On Timer Disable CADUT01 CR Optional GS1 128 Add On Time...

Страница 116: ...r 70ms CADUT0A CR Optional GS1 128 Add On Timer 100ms CADUT0C CR Optional GS1 128 Add On Timer 120ms CADUT0E CR Optional GS1 128 Add On Timer 140ms CADUT10 CR Optional GS1 128 Add On Timer 160ms Enter...

Страница 117: ...28 Add On Timer 220ms CADUT18 CR Optional GS1 128 Add On Timer 240ms CADUT1A CR Optional GS1 128 Add On Timer 260ms CADUT1C CR Optional GS1 128 Add On Timer 280ms CADUT1E CR Optional GS1 128 Add On Ti...

Страница 118: ...haracter Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data char...

Страница 119: ...cter along with Code 39 bar code data CC3CT00 CR Code 39 Check Character Transmission Don t Send CC3CT01 CR Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation contin...

Страница 120: ...start and stop characters DEFAULT CC3SS00 CR Code 39 Start Stop Character Transmission Don t Transmit CC3SS01 CR Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables disables...

Страница 121: ...39 Quiet Zones Quiet Zones on two sides CC3LO03 CR Code 39 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 39 Length Control This feature specifies either variable length decoding or fixed len...

Страница 122: ...mples for setting Length 1 See page 245 for detailed instructions on set ting this feature Table 3 Code 39 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters...

Страница 123: ...Table 4 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 4 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignor...

Страница 124: ...nable Disable DEFAULT CCTEN00 CR Trioptic Code Disable CCTEN01 CR Trioptic Code Enable CODE 32 ITAL PHARMACEUTICAL CODE The following options apply to the Code 32 Italian Pharmaceutical Code symbology...

Страница 125: ...Check Char Transmission Enable this option to transmit the check character along with Code 32 bar code data DEFAULT CP3CT00 CR Code 32 Check Character Transmission Don t Send CP3CT01 CR Code 32 Check...

Страница 126: ...le Enables Disables ability of the reader to decode Code 39 CIP labels DEFAULT CCCEN00 CR Code 39 CIP Disable CCCEN01 CR Code 39 CIP Enable CODE 39 DANISH PPT The following options apply to the Code 3...

Страница 127: ...es disables the ability of the scanner to decode Code39 La Poste labels DEFAULT CLPEN00 CR Code 39 LaPoste Disable CLPEN01 CR Code 39 LaPoste Enable CODE 39 PZN The following options apply to the Code...

Страница 128: ...able Disable When disabled the reader will not read Code 128 bar codes CC8EN00 CR Code 128 Disable CC8EN01 CR Code 128 Enable DEFAULT Expand Code 128 to Code 39 This feature enables disables expansion...

Страница 129: ...bar code data DEFAULT CC8CT00 CR Code 128 Check Character Transmission Don t Send CC8CT01 CR Code 128 Check Character Transmission Send Code 128 Function Character Transmission Enables disables trans...

Страница 130: ...he narrowest bar or space in the label CC8LO02 CR Code 128 Quiet Zones Quiet Zones on two sides CC8LO03 CR Code 128 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 128 Length Control This feat...

Страница 131: ...me examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 5 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Charac...

Страница 132: ...fixed length Table 6 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 6 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Se...

Страница 133: ...e Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels CU8EN00CR GS1 128 Transmit in Code 128 data format CU8EN01CR GS1 128 Tra...

Страница 134: ...8 concatenation of 2 labels DEFAULT CI8CE00 CR ISBN 128 Concatenation Disable CI8CE01 CR ISBN 128 Concatenation Enable ISBT 128 Force Concatenation When enabled this feature forces concatenation for I...

Страница 135: ...catenation Mode Specifies the concatenation mode between Static and Dynamic NOTE DEFAULT CI8CM00CR ISBT 128 Concatenation Mode Static CI8CM01CR ISBT 128 Concatenation Mode Dynamic This option is only...

Страница 136: ...de CI8DT05 CR ISBT 128 Dynamic Concatenation Timeout 50 msec CI8DT0A CR ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT CI8DT14 CR ISBT 128 Dynamic Concatenation Timeout 200 msec CI8DT32 CR IS...

Страница 137: ...s NOTE To set up pairs of label types for concatenation contact Technical Support INTERLEAVED 2 OF 5 I 2 OF 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disable...

Страница 138: ...Technical Support DEFAULT CI2CC00 CR I 2 of 5 Check Character Calculation Disable CI2CC01 CR I 2 of 5 Check Character Calculation Check Standard Modulo 10 CI2CC02 CR I2of5CheckCharacterCalculation Ch...

Страница 139: ...I2CT01 CR I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology Variable...

Страница 140: ...etting Length 1 See page 245 for detailed instructions on setting this feature Table 7 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters...

Страница 141: ...able 8 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 8 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore T...

Страница 142: ...bles Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels DEFAULT CCHEN00 CR Interleaved 2 of 5 CIP HR Disable CCHEN01 CR Interleaved 2 of 5 CIP HR Enable FOLLETT 2 OF 5 The following...

Страница 143: ...er will not read Standard 2 of 5 bar codes DEFAULT CS2EN00 CR Standard 2 of 5 Disable CS2EN01 CR Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calcula...

Страница 144: ...dard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology V...

Страница 145: ...some examples for setting Length 1 See page 245 if you want detailed instructions on setting this feature Table 9 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 C...

Страница 146: ...h Table 10 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 10 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Sett...

Страница 147: ...ty of reader to decode Industrial 2 of 5 labels DEFAULT CU2EN00 CR Industrial 2 of 5 Disable CU2EN01 CR Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculat...

Страница 148: ...2 of 5 Check Character Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology...

Страница 149: ...examples for setting Length 1 See page 245 if you want detailed instructions on setting this feature Table 11 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Cha...

Страница 150: ...ies to ignore this length only one fixed length Table 12 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 12 Industrial 2 of 5 Length 2 Sett...

Страница 151: ...es Disables the ability of the reader to decode IATA labels DEFAULT CIAEN00 CR IATA Disable CIAEN01 CR IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an...

Страница 152: ...able Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label is tr...

Страница 153: ...a CCBCT00 CR Codabar Check Character Transmission Don t Send CCBCT01 CR Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable...

Страница 154: ...BCD TN E CCBSC01 CR Codabar Check Character Set ABCD ABCD CCBSC02 CR Codabar Check Character Set abcd tn e CCBSC03 CR Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Character Match W...

Страница 155: ...Quiet Zones Quiet Zones on two sides CCBLO03 CR Codabar Quiet Zones Small Quiet Zones on two sides DEFAULT Codabar Length Control This feature specifies either variable length decoding or fixed lengt...

Страница 156: ...o 50 characters Table 13 provides some examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 13 Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 De...

Страница 157: ...of 0 specifies to ignore this length only one fixed length Table 14 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 14 Codabar Length 2 Se...

Страница 158: ...le Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT CCBAB00 CR ABC Codabar Disable CCBAB01 CR ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenati...

Страница 159: ...catenation Mode CCBDT05 CR ABC Codabar Dynamic Concatenation Timeout 50 msec CCBDT0A CR ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT CCBDT14 CR ABC Codabar Dynamic Concatenation Timeout...

Страница 160: ...ABC Codabar 150 Wasp WWS650 ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated DEFAULT CCBFC00 CR ABC Codabar Force Concatenation Disable CCBFC01 CR ABC Codabar...

Страница 161: ...T CC1EN00 CR Code 11 Disable CC1EN01 CR Code 11 Enable Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character CC1CC00 CR Code...

Страница 162: ...Code 11 Check Character Transmission Send DEFAULT Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology Variable Length For v...

Страница 163: ...examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 15 Code 11 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 0...

Страница 164: ...h Table 16 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 16 Code 11 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad...

Страница 165: ...e reader will not read GS1 DataBar Omnidirectional bar codes DEFAULT C4BEN00 CR GS1 DataBar Omnidirectional Disable C4BEN01 CR GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Em...

Страница 166: ...1 DataBar Omnidirectional 2D Component Disable 2D component not required C4B2D01 CR GS1 DataBar Omnidirectional 2D Component 2D component must be decoded GS1 DATABAR EXPANDED The following options app...

Страница 167: ...mat DEFAULT CXBU800 CR GS1 DataBar Expanded GS1 128 Emulation Disable CXBU801 CR GS1 DataBar Expanded GS1 128 Emulation Enable GS1 DataBar Expanded 2D Component This feature enables disables a require...

Страница 168: ...ecoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different le...

Страница 169: ...ome examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 17 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Chara...

Страница 170: ...d length Table 18 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 18 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1...

Страница 171: ...e When disabled the reader will not read GS1 DataBar Limited bar codes DEFAULT CLBEN00 CR GS1 DataBar Limited Disable CLBEN01 CR GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When e...

Страница 172: ...his symbology is decoded DEFAULT CLB2D00 CR GS1 DataBar Limited 2D Component Disable 2D component not required CLB2D01 CR GS1 DataBar Limited 2D Component 2D component must be decoded CODE 93 The foll...

Страница 173: ...on Disable CC9CC01 CR Code 93 Check Character Calculation Enable Check C CC9CC02 CR Code 93 Check Character Calculation Enable Check K CC9CC03 CR Code 93 Check Character Calculation Enable Check C and...

Страница 174: ...length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diffe...

Страница 175: ...ome examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 19 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Char...

Страница 176: ...es to ignore this length only one fixed length Table 20 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 20 CODE 93 Length 2 Setting Example...

Страница 177: ...for Code 93 CC9LO02 CR Code 93 Quiet Zones Quiet Zones on two sides CC9LO03 CR Code 93 Quiet Zones Small Quiet Zones on two sides DEFAULT MSI The following options apply to the MSI symbology MSI Enab...

Страница 178: ...lation Disable CMSCC01 CR MSI Check Character Calculation Enable Mod10 DEFAULT CMSCC02 CR MSI Check Character Calculation Enable Mod11 10 CMSCC03 CR MSI Check Character Calculation Enable Mod10 10 MSI...

Страница 179: ...her variable length decoding or fixed length decoding for the MSI sym bology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding...

Страница 180: ...examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 21 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters...

Страница 181: ...of 0 specifies to ignore this length only one fixed length Table 22 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 22 MSI Length 2 Setting...

Страница 182: ...lessey Check Character Calculation Enables Disables calculation and verification of an optional Plessey check character CPLCC00 CR Plessey Check Character Calculation Disable CPLCC01 CR Plessey Check...

Страница 183: ...R Plessey Check Character Transmission Enable DEFAULT Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology Variable Length F...

Страница 184: ...examples for setting Length 1 See page 245 for detailed instructions on setting this feature Table 23 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Charact...

Страница 185: ...0 specifies to ignore this length only one fixed length Table 24 provides examples for setting Length 2 See page 245 for detailed instructions on set ting this feature Table 24 Plessey Length 2 Setti...

Страница 186: ...Enter Exit Programming Mode Plessey 176 Wasp WWS650 NOTES...

Страница 187: ...green arrow Also reference Appendix B Standard Defaults for a listing of the most widely used set of standard factory set tings That section also provides space to record any custom settings needed or...

Страница 188: ...ectable range is 10 milliseconds to 2 55 milliseconds CDETM0A CR 2D Maximum Decoding Time 100 msec CDETM32 CR 2D Maximum Decoding Time 200 msec CDETM23 CR 2D Maximum Decoding Time 350 msec DEFAULT CDE...

Страница 189: ...Append Enable 2D Normal Inverse Symbol Control Specifies the options available for decoding normal negative printed 2D symbols This configu ration item applies globally to all the 2D symbologies that...

Страница 190: ...1 CR Aztec Code Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decoding a mini...

Страница 191: ...of 0001 pad with zeroes See page 245 for detailed instructions on setting this feature CAZL1 Select Aztec Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar cod...

Страница 192: ...ad with zeroes See page 245 for detailed instructions on setting this feature CAZL2 Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above th...

Страница 193: ...CCSEN01 CR China Sensible Code Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variabl...

Страница 194: ...with zeroes See page 245 for detailed instructions on setting this feature CCSL1 Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code a...

Страница 195: ...incre ments of 0001 pad with zeroes See page 245 for detailed instructions on setting this feature CCSL2 Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO...

Страница 196: ...ilable when reading Data Matrix with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a bit mask to...

Страница 197: ...Control on page 187 Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 116 characters in increments...

Страница 198: ...pad with zeroes See page 245 for detailed instructions on setting this feature CDML2 Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above...

Страница 199: ...ecode Maxicode labels DEFAULT CMXEN00 CR Maxicode Disable CMXEN01 CR Maxicode Enable Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Second...

Страница 200: ...ngth 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 0145 characters in increments of 0001 pad with zeroes...

Страница 201: ...ements of 0001 pad with zeroes See page 245 for detailed instructions on setting this feature CMXL2 Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar...

Страница 202: ...DEFAULT PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decoding a minimum and maximum le...

Страница 203: ...increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 245 for detailed instructions on setting this feature CP4L1 Select PDF417 Length 1 Setting To configure this feat...

Страница 204: ...racters pad with zeroes in increments of 01 Any value greater than 2 710 will be consid ered to be 2 710 See page 245 for detailed instructions on setting this feature CP4L2 Select PDF417 Length 2 Set...

Страница 205: ...IEN01 CR Micro PDF417 Enable Micro PDF417 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID a...

Страница 206: ...ble Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only Characters can be set from 0001 to 0366 characters pad with zeroes in increments o...

Страница 207: ...es in increments of 01 Any value greater than 0366 will be considered to be 0366 See page 245 for detailed instructions on setting this feature CMIL2 Select Micro PDF417 Length 2 Setting To configure...

Страница 208: ...e DEFAULT QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decoding a minimum and maximum...

Страница 209: ...f 0001 pad with zeroes See page 245 for detailed instructions on setting this feature CQRL1 Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code abo...

Страница 210: ...d with zeroes See page 245 for detailed instructions on setting this feature CQRL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then t...

Страница 211: ...MQEN01 Micro QR Code Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decodin...

Страница 212: ...h zeroes See page 245 for detailed instructions on setting this feature CMQL1 Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then...

Страница 213: ...incre ments of 0001 pad with zeroes See page 245 for detailed instructions on setting this feature CMQL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE...

Страница 214: ...ble Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label NOTE DEFAULT CCMEN00 CR UCC Composite Disable CCMEN01 CR UCC Composite Enable This feature is...

Страница 215: ...fore transmitting the linear label without an add on DEFAULT CCMOT00 CR UCC Optional Composite Timer Timer Disabled CCMOT01 CR UCC Optional Composite Timer 100msec CCMOT02 CR UCC Optional Composite Ti...

Страница 216: ...ost Postnet Japan Post Planet IMB Royal Mail Sweden Post Kix Portugal Post DEFAULT CPOEN00 CR Postal Code Selection Disable All Postal Codes CPOEN01 CR Postal Code Selection Enable Postnet CPOEN02 CR...

Страница 217: ...Postal Code Selection Enable IMB CPOEN08 CR Postal Code Selection Enable Sweden Post CPOEN09 CR Postal Code Selection Enable Portugal Post Postnet BB Control Controls the ability of the scanner to de...

Страница 218: ...Symbology Selection 208 Wasp WWS650 NOTES...

Страница 219: ...n to Scanner on page 215 Copy Configuration to Base Station on page 216 BATCH FEATURES starting on page 216 Batch Mode on page 216 Send Batch on page 217 Erase Batch Memory on page 217 RF Batch Mode T...

Страница 220: ...ication When enabled a beep occurs when a Label is correctly transmitted to the base CBTAB00 CR Good Transmission Beep Disable CBTAB01 CR Good Transmission Beep Enable DEFAULT Beep Frequency Adjusts r...

Страница 221: ...tion of radio specific beep indications CBTBD06 CR Beep Duration 60 msec CBTBD08 CR Beep Duration 80 msec DEFAULT CBTBD0A CR Beep Duration 100 msec CBTBD0C CR Beep Duration 120 msec CBTBD0E CR Beep Du...

Страница 222: ...able volume levels CBTBV00 CR Beep Volume Low CBTBV01 CR Beep Volume Medium CBTBV02 CR Beep Volume High DEFAULT Disconnect Beep Enables disables the beep indication that a handheld has become connecte...

Страница 223: ...ee per second when the handheld goes out of range This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader...

Страница 224: ...atures 214 Wasp WWS650 Leash Alarm continued CBTLB03 CR Leash Alarm 3 Seconds CBTLB04 CR Leash Alarm 4 Seconds CBTLB05 CR Leash Alarm 5 Seconds CBTLB0A CR Leash Alarm 10 Seconds CBTLB19 CR Leash Alarm...

Страница 225: ...ication hardware and or configuration CBTCU00 CR Automatic Configuration Update Disable CBTCU01 CR Automatic Configuration Update Enable DEFAULT Copy Configuration to Scanner Scan the following label...

Страница 226: ...MING MODE label with this bar code BATCH FEATURES Batch Mode This option specifies whether to store labels in the handheld while disconnected from the base Options are as follows Disabled The handheld...

Страница 227: ...ase Batch Memory When the scanner is configured in Manual Batch Mode use the following bar code to erase any labels stored in batch memory NOTE BatchClear Erase Batch Memory Do not scan an ENTER EXIT...

Страница 228: ...to a base station without scanning the Unlink label first DEFAULT CBTDL00 CR Direct Radio Link Unlink Label Required CBTDL01 CR Direct Radio Link Automatic Unlinking RF Batch ModeTransmit Delay conti...

Страница 229: ...so at what position with respect to the label data See page 264 in References for detailed information and examples for setting this feature NOTE DEFAULT CBTAS00 CR Source Radio Address Transmission...

Страница 230: ...e this feature scan the ENTER EXIT PROGRAM MING MODE bar code above then the bar code at left fol lowed by the digits from the Alphanumeric characters in Appendix D Keypad representing your desired ch...

Страница 231: ...n Select PIN Code Length on page 222 3 Scan the relevant bar code from Set PIN Code on page 222 then scan the desired alpha numeric characters from the keypad in Appendix D Keypad to set the PIN code...

Страница 232: ...nvert to hexadecimal using the ASCII Chart on the inside back cover of this manual See page 265 for detailed information and examples for setting this feature CBTPC Set 4 character BT PIN Code To conf...

Страница 233: ...to Discover new devices and select Wasp Scan ner Use a text editor to see incoming data on the port designated by the computer s Bluetooth manager If you receive an error message it may be necessary t...

Страница 234: ...e HID Alt Mode feature HID Alt Mode OFF DEFAULT DEFAULT HID Alt Mode ON Bluetooth HID Send Unknown ASCII Char Unknown characters are characters the host does not recognize When Disable HID Send ASCII...

Страница 235: ...feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by a maximum 64 digits from the Alphanumeric characters in Appendix D Keypad The digits must be the hexa...

Страница 236: ...Bluetooth Adapter in HID mode you may want to set the country for which your PC is localized In order to do that read one of the configuration com mand labels below Country Mode U S Country Mode Belg...

Страница 237: ...g Mode Product Reference Guide 227 HID Country Mode continued Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithu...

Страница 238: ...t Programming Mode Other BT Features 228 Wasp WWS650 HID Country Mode continued Country Mode Portugal Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Swi...

Страница 239: ...for automatically switching the unit off when the imager has been idle CSLPS00 CR Powerdown Timeout Disable CSLPS01 CR Powerdown Timeout 10 minutes CSLPS02 CR Powerdown Timeout 20 minutes R CSLPS03 CR...

Страница 240: ...Enter Exit Programming Mode Other BT Features 230 Wasp WWS650 NOTES...

Страница 241: ...can receive host message only if Host Commands Obey Ignore is set to Ignore Message could be sent to the HH in response to a Label when Transmit mode require Ack from Host see transmit mode parameter...

Страница 242: ...SC 0 r Beep for Find me function new ESC 1 r Power off new The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper T...

Страница 243: ...RS 232 RS 232 USB COM Parameters KEYBOARD INTERFACE starting on page 242 Wedge Quiet Interval Intercharacter Delay Intercode Delay DATA EDITING starting on page 246 Global Prefix Suffix Global AIM ID...

Страница 244: ...ding to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contain...

Страница 245: ...G 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last characte...

Страница 246: ...ers 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits 1 Determine the desired character or value 2 Use the ASCII Chart on the inside back cover of this manual to find...

Страница 247: ...scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendi...

Страница 248: ...he appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If...

Страница 249: ...ix D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the...

Страница 250: ...and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in...

Страница 251: ...aracter value 3 Go to page 36 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate two alphanumeric c...

Страница 252: ...riate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make...

Страница 253: ...AY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last...

Страница 254: ...duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and...

Страница 255: ...selected symbology 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length setting which was determined in the steps above You will hear a two beep indica tion...

Страница 256: ...user defined data is called a message string The Data Editing features can be used to build specific user defined data into a message string There are several types of selectable data characters that...

Страница 257: ...d in Figure 5 Figure 5 Prefix and Suffix Positions Prefix Suffix AIM ID Label ID Label ID Bar Code Data 00 20 Characters ASCII AND OR OR Example Setting a Prefix In this example we ll set a prefix for...

Страница 258: ...identifiers consist of three charac ters as follows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dep...

Страница 259: ...ader supports two pre loaded sets of Label IDs Table 35 shows the USA and the EU sets CAUTION When changing from one Label ID set to another all other reader configuration settings including the host...

Страница 260: ...4C0000 EAN13 P5 F 460000 M 4D0000 EAN13 COMPOSITE F 460000 F 244600 EAN8 FF 464600 A 410000 EAN8 P2 FF 464600 J 4A0000 EAN8 P5 FF 464600 K 4B0000 EAN8 COMPOSITE FF 464600 G 244700 FOLLET 2OF5 O 4F000...

Страница 261: ...TAL PORTUGAL P 245000 P 245000 POSTAL POSTNET BB L 244C00 L 244C00 POSTAL ROYAL MAIL M 244D00 M 244D00 POSTAL SWEDISH X 245800 X 245800 POSTNET 1 310000 1 310000 QR CODE QR 515200 y 790000 S25 s 73000...

Страница 262: ...Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID...

Страница 263: ...58 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII Chart inside back cover then scan in these...

Страница 264: ...uld look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 char acters Nothing is done with the last two chara...

Страница 265: ...OD READ LED DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will hear a two beep indicat...

Страница 266: ...en released and pulled again Double Read Time out prevents undesired multiple reads of the same label while in this mode Flashing The reader flashes on and off regardless of the trigger status Flash r...

Страница 267: ...ar code Set Stand Mode Illuminator Off Time 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the setting which was determined in the steps above You will hear a tw...

Страница 268: ...esent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to...

Страница 269: ...hat represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar...

Страница 270: ...Appendix D Keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character s...

Страница 271: ...in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last charac...

Страница 272: ...the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alphanumeric characters from the key...

Страница 273: ...3B LABELIMAGE 12 Reserved 3C CAPTURE_IMAGE_LABEL 13 CODE49 3D Reserved 14 UPC E2 3E M2OF5 15 UPC E5 3F D2OF5 16 Reserved 40 PLESSEY65 17 UPC A2 42 ISSN 18 UPC A5 43 ISBT 19 Reserved 44 Reserved 1A EAN...

Страница 274: ...nd its hexadecimal equivalent on the ASCII Chart on the inside back cover A setting of 00 specifies no delimiter character 2 Go to page 220 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter P...

Страница 275: ...ication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning 7 Scan t...

Страница 276: ...266 Wasp WWS650 NOTES...

Страница 277: ...ry Type Li Ion battery pack Typical charge time for full charge from full discharge 6 hours with Host Power through the micro USB cable connection 4 hours with Base and 12V external power supply adapt...

Страница 278: ...A typi cal environmental light 20 C label inclination 10 Symbology Code 39 5mil 0 2 5 9 0 5 15cm 10mil 0 8 7 0 22cm 20mil up to 16 40cm EAN 7 5mil 0 5 9 0 15cm 13mil 0 2 13 8 0 5 35cm PDF 417 6 6mil 0...

Страница 279: ...nfigurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 characters Maxicode QR Codes QR and Multiple QR Codes Aztec Postal Codes Australian Post Japan...

Страница 280: ...from 1 5 meters 5 0 feet to concrete Ambient Light Immunity Up to 86 000 Lux Contaminants Spray Rain Dust Particulates IEC 529 IP42 IP51 QD2430 E model only ESD Level 16 KV Regulatory Electrical Safet...

Страница 281: ...your product for actual details as they may vary from those depicted Scanner Regulatory Label CAUTION The Wasp WWS650 Handheld Reader is not user serviceable Opening the case of the unit can cause in...

Страница 282: ...erface cable Figure 9 Standard Cable Pinouts Handheld Pin 10 Cable Clip Latch To Host Cable Cable Strain Relief Bottom of Scanner Interface Cable Port Pin 1 Figure 10 Standard Cable Pinouts Base Stati...

Страница 283: ...273 Table 46 Standard Cable Pinouts Pin RS 232 OEM USB Keyboard Wedge 1 RTS out 2 D CLKIN KBD side 3 D DATAIN KBD side 4 GND GND GND GND 5 RX 6 TX 7 VCC VCC VCC VCC 8 IBM_B CLKOUT PC side 9 IBM_A DAT...

Страница 284: ...volume mono bi tonal setting and duration upon a successful label scan ROM Failure There is an error in the reader s software programming Flashes Reader sounds one error beep at highest volume Limite...

Страница 285: ...Program ming Mode Acceptance of Programming Configuration option s have been successfully programmed via labels and the reader has exited Programming Mode N A Reader sounds one high fre quency beep a...

Страница 286: ...is in prog ress Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Green LED on Battery charger error Green LED and Red LEDs blink alternatively 1Hz No handheld i...

Страница 287: ...efaults Parameter Default Your Setting Page Number GLOBAL INTERFACE FEATURES Host Commands Obey Ignore Obey 23 USB Suspend Mode Disable 23 RS 232 ONLY Baud Rate 9600 26 Data Bits 8 Data Bits 27 Stop B...

Страница 288: ...rface Options Ignore Scanner Configura tion Host Commands 48 DATA FORMAT Global Prefix Suffix No Global Prefix Global Suffix 0x0D CR 52 Global AIM ID Disable 53 Set AIM ID Individually for GS1 128 Ena...

Страница 289: ...e 5 Seconds 77 Stand Illumination Control OFF 78 Flash On Time 10 Flash is ON for 1 Sec ond 78 Flash Off Time 06 Flash is OFF for 600ms 79 Aiming Pointer Enable 79 Aiming Duration Timer Aiming Off Aft...

Страница 290: ...le Enable 90 UPC E Check Character Transmission Send 91 UPC E 2D Component 2D Component Not Required 91 Expand UPC E to EAN 13 Don t Expand 92 Expand UPC E to UPC A Don t Expand 92 UPC E Number System...

Страница 291: ...isable 105 Code 39 Code 39 Enable Disable Enable 108 Code 39 Check Character Calculation Disable 108 Code 39 Check Character Transmission Send 109 Code 39 Start Stop Character Trans mission Don t Tran...

Страница 292: ...ter Transmis sion Don t Send 119 Code 128 Function Character Trans mission Don t Send 119 Code 128 Quiet Zones Small Quiet Zones on two sides 120 Code 128 Length Control Variable 120 Code 128 Set Leng...

Страница 293: ...Character Calcu lation Disable 133 Standard 2 of 5 Check Character Transmission Send 134 Standard 2 of 5 Length Control Variable 134 Standard 2 of 5 Set Length 1 8 135 Standard 2 of 5 Set Length 2 50...

Страница 294: ...Set Length 1 3 146 Codabar Set Length 2 50 147 ABC Codabar Disable 148 ABC Codabar ABC Codabar Enable Disable Disable 148 ABC Codabar Concatenation Mode Static 148 ABC Codabar Dynamic Concatenation Ti...

Страница 295: ...aBar Expanded Set Length 2 74 160 GS1 DataBar Limited GS1 DataBar Limited Enable Disable Disable 161 GS1 DataBar Limited GS1 128 Emula tion Disable 161 GS1 DataBar Limited 2D Component 2D component no...

Страница 296: ...c 178 2D Structured Append Disable 179 2D Normal Inverse Symbol Control Normal 179 Aztec Code Enable Disable Disable 180 Aztec Code Length Control Enable 180 Aztec Code Length Control Variable 180 Azt...

Страница 297: ...ro PDF417 Length Control Variable 196 Micro PDF417 Set Length 1 1 196 Micro PDF417 Set Length 2 0366 197 QR Code Enable Disable Enable 198 QR Code Length Control Variable 198 QR Code Set Length 1 1 19...

Страница 298: ...Unlink Label Required 218 Features for BT Models Only Source Radio Address Transmission Do not include 219 Source Radio Address Delimiter Char acter No Delimiter Character 220 BT Security Features BT...

Страница 299: ...e Guide 289 Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes UPC A EAN 13 978033029095 Code 39 Code 128 Code 128 Int...

Страница 300: ...290 Wasp WWS650 Sample Bar Codes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...

Страница 301: ...anded 1234890hjio9900mnb GS1 DataBar Limited 08672345650916 GS1 DataBar variants must be enabled to read the bar codes below see GS1 DataBar Omnidirectional on page 155 GS1 DataBar 14 GS1 DataBar Omni...

Страница 302: ...292 Wasp WWS650 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF 417 ABCabc Micro PDF 417 BV17453 QR Code 35900G9 Micro QR Code 123456 UCC Composite...

Страница 303: ...Product Reference Guide 293 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5 6 7 8 9...

Страница 304: ...294 Wasp WWS650 A B C D E F...

Страница 305: ...aracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII tab...

Страница 306: ...1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R...

Страница 307: ...02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9...

Страница 308: ...092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 12...

Страница 309: ...112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 01...

Страница 310: ...S C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh Ins Ent ke...

Страница 311: ...3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12...

Страница 312: ...ace 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F1...

Страница 313: ...uct Reference Guide 303 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some oth...

Страница 314: ...Scancode Tables 304 Wasp WWS650 NOTES...

Страница 315: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 316: ...Wasp Barcode Technologies 1400 10th Street Plano Texas USA 75074 2013 2018 Wasp Barcode Technologies www waspbarcode com 820059990 RevA Sept 2018...

Отзывы: