Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume
that it is in a motionless condition. The range for this setting is from 500
msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
= 0005 = 00, 5 = 050, 20 = 200, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar-
code to enter Programming Mode.
4. Scan the barcode: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
representing the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
for examples of how to set this
feature.
Table 46. Motionless Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1 sec.
10 sec
9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits)
005
010
100
250
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘0’
‘1’, ‘0’, and ‘0’
‘2’, ‘5’, and ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Wasp WDI7500
Страница 1: ...Wasp WDI7500 Wasp WWS750 2D Duraline USB or Wireless Barcode Scanner Product Reference Guide...
Страница 10: ...viii Wasp WDI7500 WWS750 NOTES...
Страница 282: ...Sample Barcodes 272 Wasp WDI7500 WWS750 Sample Barcodes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...
Страница 308: ...Microsoft Windows Codepage 1252 Product Reference Guide 298 NOTES...