13
Alternate LIQUID/POWDER
Electrical connection
At the rear of the machine, next to the electrical
connection block there will be either a single one
or a pair of quick-disconnect connectors,
depending on the date of the machine. For
machines with a serial number up to 95/... there
will be two connectors. The one with a single
jumper wire is to be plugged in when external
liquid supplies are used. The one with three
jumper wires is used for powder supplies. For
machines with a serial number starting with 96/
28012 – (FL 125) and 96/13445 (FL 185) the
single connector is plugged in only for powder
supplies.
Pump connection
At the rear of the machine to the right of the
incomming power connection block are the
connections for pumps. Depending on the
number of pumps to be connected, they shall be
connected from 1-5 and C (common). The pumps
obtain trigger signals from the program card via
the connections.
Rib A
controls connection 1
Rib F
–’’–
2
Rib E
–’’–
3
Rib G
–’’–
4
Rib I
–’’–
5
Note!
Remember that it is only a signal which is
obtained from the machine to the pumps
and not time controlling.
Installation
25
26
1922
1
2
3
4
5
C
1840 B
Fig.
25
Fig.
26