Electrical installation
Although the machines are fitted with a thermal
overload in the motor windings, a separate three-
phase common-trip circuit breaker must be
installed for all three-phase machines.
For proper overcurrent protection, check the data
plate at the rear of the machine. Also consult
local electrical code for special requirements.
Use inverse-time circuit breaker only.
Connect L1, L2, L3 and ground wires according
to the markings of the terminal block. The cable
is to hang in a large loose loop, supported by the
clip of the terminal block.
After installation, do the following for 3-phase
machines
Check the incoming power for a high voltage or
"stinger" leg. This will usually measure higher
than 150 Volts to ground. If present, connect that
line to L2 on the terminal block.
Recommended overcurrent protection
FL 125
3-phase
15A max.
FL 125
1-phase
20A max.
FL 185
3-phase
15A max.
FL 185
1-phase
20A max.
Start the machine and check that the drum
rotates in the proper direction during extraction,
counter-clockwise when seen from the front. If
the drum rotates in the wrong direction interchar-
ge line L1 and L3 at the power connection termi-
nal.