CONTACTING CUSTOMER SERVICE

For assistance, contact Customer Service. Office hours are 

from 8:00 AM until 5:00 PM ET.

Email:

 

[email protected]

Web:

  

warmlyyours.com

RETURNS AND REPLACEMENT PART PURCHASES

Equipment cannot be returned for credit once it has 

been installed. ETI will repair or replace faulty equip-

ment under warranty. Prior to removal of equipment for 

warranty return, please contact ETI Technical Support for 

troubleshooting assistance.
Before returning a unit to ETI, obtain a Return Merchandise 

Authorization  from  our  Customer  Service  Department, 

available between 8:00 a.m. and 5:00 p.m. Eastern Time. If 

possible, use the original container and packing materials 

when packing the unit for shipment. It is important to 

mark  the  Return  Merchandise  Authorization  clearly 

on the outside of the shipping container so that it may 

be correctly processed upon receipt at Environmental 

Technology. For more information about replacement 

parts or for a replacement Data Sheet or Manual, please 

visit www.networketi.com.

LIMITED WARRANTY

ETI’s two year limited warranty covering defects in 

workmanship and materials applies. Contact Customer 

Service for complete warranty information.

DISCLAIMER

ETI makes no representations or warranties, either 

expressed or implied, with respect to the contents 

of this publication or the products that it describes, 

and  specifically  disclaims  any  implied  warranties  of 

merchantability or fitness for any particular purpose. ETI 

reserves the right to revise this publication, and to make 

changes and improvements to the products described 

in this publication, without the obligation of ETI to notify 

any person or organization of such revisions, changes or 

improvements.

Copyright © 2019 ETI,

®

 All rights reserved.

Содержание TRACON PT-SINGLE

Страница 1: ...l Odor or Smoke In the event of smoke or a burning or abnormal odor immediately interruptpowertotheunitbyturningoff thecircuitbreakerprotecting the unit Electrical Shock Fire Hazard Any installation i...

Страница 2: ...nection The internal load contactor is rated to South Bend Indiana USA networketi com switch up to 30 A resistive The Integral GFEP provides safety in compliance with national and local electrical cod...

Страница 3: ...e only Listed Type 4X IP66 liquid tight conduit hubs or cable glands Connect the hub to the conduit system before connecting the hub to the enclosure The unit comes with two installed liquid tight cab...

Страница 4: ...PST contacts rated for heater loads up to 30 A ac and 277 V ac These two contacts are used to control both legs of the input power Line and Neutral Manual Load Test To manually energize the load selec...

Страница 5: ...to 230 F 40 C to 110 C See Figure 5 for proper wiring when using a thermistor sensor RTD The unit can use an RTD sensor for applications requiring a wider temperature range The PT SINGLE can operate...

Страница 6: ...contact to open to signal an alarm or power off condition then connect the other alarm relay lead to the NO Normally Open terminal If the unit has power and there are no alarm conditions then the NO...

Страница 7: ...en the heater is energized LOW TEMP indicator This blue LED indicates when sensors detect temperature has fallen below the Low Temp Alarm threshold ALARM indicator This red LED indicates when there is...

Страница 8: ...Load Current alarm you must view the Load Current Display screen Note If the heater relay is off the ground fault number is NOT shown Temperature Display screen Indicates the current temperature in Fa...

Страница 9: ...eens that display multiple fields there are two columns The left column displays the name of the parameter and the right column displays the current value Initially one of the fields in the left colum...

Страница 10: ...South Bend Indiana USA networketi com PT SINGLE INSTALLATION MANUAL PART NO 25166 REV D 10 FIGURE 10 Setting screen sequence...

Страница 11: ...High temperature alarm delay 0 s to 3000 s Default 300 s Low current alarm threshold 0 0 A to 10 0 A Default 0 1 A Enabled Low current alarm delay 0 s to 300 s Default 5 s Enabled High current alarm t...

Страница 12: ...to mark the Return Merchandise Authorization clearly on the outside of the shipping container so that it may be correctly processed upon receipt at Environmental Technology For more information about...

Отзывы: