CENTER 352 

INFRARED THERMOMETER 
INSTRUCTION MANUAL 

 
 
 

OPEN

LASER RADIATION -

 OUTPUT < 1mW  AT 630    670mm

DO NOT STARE INTO BEAM

CLASS II  LASER  PRODUCT

CAUTION

 

 
 
 

Warning of laser 

Do not point laser beam to human eyes directly or indirectly from 
reflective surfaces. 
 

Cautions 

Before using the infrared thermometer the operator have to notice 
the following: 

 

Keep away from electrical welders, induction heaters and other 
EMF sources. 

 

When using this thermometer under big or abrupt ambient 
temperature changes, allow 15 minutes for the unit to stabilize 
before use. 

 

Do not keep this thermometer in the environment of high 
temperature for a long period. 

 

Keep away from dusty environment and keep it in the carry 
case after operation to avoid contamination of optical lenses. 

 

LCD Display 

 

HOLD

SCAN

 

 

 

 

Low battery symbol

 

Temperature unit 
indication

 

Data Hold indication 

 

Laser On indication

 

Digital readout

 

Scanning indication

 

Содержание Center 352

Страница 1: ...away from electrical welders induction heaters and other EMF sources When using this thermometer under big or abrupt ambient temperature changes allow 15 minutes for the unit to stabilize before use Do not keep this thermometer in the environment of high temperature for a long period Keep away from dusty environment and keep it in the carry case after operation to avoid contamination of optical le...

Страница 2: ...r 10 seconds this thermometer will power down itself to save battery 6 Battery cover 7 LCD display Changing Battery When the battery voltage drops below the required range for reliable operation the low battery symbol will appear indicating it is time to replace the battery To change the 9V battery detach the battery compartment cover by pushing the engraved pattern on the handle and pull down Cha...

Страница 3: ... moistened with water NOTE DO NOT use solvents to clean the glass lens GENERAL SPECIFICATIONS Field of View 12 1 Detector Thermopile Temperature Range 20 500 C 4 932 F Resolution 0 1 C 0 2 F Operation Temperature Humidity 0 40 C 32 104 F 10 90 RH Storage Temperature Humidity 10 60 C 14 140 F 75 RH Accuracy 2 C 4 F or 2 of reading Repeatability Within 1 of reading or 1 C 2 F Response Time 0 5 secon...

Страница 4: ... 1997 Electromagnetic Susceptibility Tests were conducted using a frequency range of 80 1000 MHz with the instrument in three orientations The average error for the three orientations is 1 5 C 3 0 F at 3V m throughout the spectrum However between 162 MHz and 792 MHz at 3V m the instrument may not meet its stated accuracy ...

Отзывы: