System Components From WarmlyYours

1. The Customized Installation Plan (or layout).
2.  Heating Roll(s) (15-watt/ sq. ft.) If multiple rolls are connected to the same control 

device, they must be of the same voltage type and wired in parallel.

3. Control Device (one of the following): 
 

• SmartStat™ Programmable Thermostat

 

• EasyStat™ Non-Programmable Thermostat

4.  You may also have a relay contactor or power module, if your system is being 

installed in a large area.

IMPORTANT - Cross check the items you received against the packing 

list and the materials list on the installation plan to ensure that the roll 

length(s) and thermostat type(s) are an exact match.  

Double Check Your Dimensions

Check and verify that your plan has the correct room dimensions. Your order consists of 

the exact amount of material required to complete your project. If the measurements of 

your space have changed, this will affect how much product is required and how it will be 

installed. Once the Heating Roll is cut into panels, it cannot be returned. If you have any 

discrepancies or questions, call WarmlyYours at (800) 875-5285.

Circuit Check (Not a substitute for an OHM meter)

This device is offered in every order from WarmlyYours and is a continuity checker that 

you connect to the cold lead wires before installation of the flooring material.

Ground Fault Circuit Interrupter

GFCI or ‘GFCI-breaker’ indicating its capacity if not incorporated into the control device 

you  are  using.  This  is  a  built-in  feature  of  the  SmartStat  Programmable  Thermostat, 

EasyStat or Comfort Regulator.

Digital Ohm Meter (multi-meter)

Test the Heating Roll(s) before, during, and after the installation. A digital meter is strongly 

recommended because of the precise measurements needed. 

Electrical Housing Boxes/Switch Plates 

All control devices except a Relay Contactor fit into a double gang box. If a double gang 

box is used it will need to be fitted with a single gang mud ring. We strongly recommend 

a double gang box with a single gang mud ring as it provides more room to place all the 

wires. Heating elements of cables shall be separated at least 200mm (8 in.) from the edge 

of outlet boxes and junction boxes that are to be used for mounting surface luminaires. A 

clearance of not less than 50 mm (2 in.) shall be provided from recessed luminaires and 

their trims, ventilating openings, and other such openings in room surfaces. No heating 

cable shall be covered by any surface-mounted equipment.

Electrical Conduit

Local electrical codes often require the power leads be inside a metal or plastic conduit 

when running through the wall from the Heating Roll to the control device. When using an 

in-floor sensor, if local code requires the low voltage sensor wire be housed in conduit, it 

must use a separate conduit from the power leads(high voltage).

A Permanent Marker And Tape Measure 

To measure and mark Installation Plan points onto the prepared subfloor as well as where 

to alter the Fiberglass Mesh of the Heating Roll(s).

Utility Scissors

Scissors are the best tool to trim and alter the Fiberglass Mesh of the Heating Roll and to 

separate any lengths of Heating Element from the Mesh. Never cut the Heating Element. 

Hot Glue Gun, Double-Sided Tape and/or Stapler

Use these tools to affix the Fiberglass Mesh portion of the Heating Roll to the prepared 

subfloor before covering with thin-set cement. Beware that misuse of a stapler can cause 

damage to the Heating Element. NEVER staple across or on top of the wires. Hi-temp 

duct tape, like 3M 6969 is suggested.

Off-Cuts Of Cardboard Or Carpet Scraps 

This protects the Heating Element during the installation.

Items Needed For The System Installation

2

Содержание TempZone

Страница 1: ...1 1 Free Design Service 24 7 Installation Support No Nonsense Warranty 800 875 5285 www WarmlyYours com Installation Manual for your TempZone Electric Radiant Floor Heating System Twin Conductor...

Страница 2: ...ted surface temperatures and lower energy usage The floor will have the capacity to warm to a comfortable temperature and in some cases can be employed as the primary heat source for that room Securin...

Страница 3: ...Electrical Housing Boxes Switch Plates All control devices except a Relay Contactor fit into a double gang box If a double gang box is used it will need to be fitted with a single gang mud ring We str...

Страница 4: ...to continue in a new direction See Page 5 for full details on how to execute turns F Free Form Space Indicates a length of Fiberglass Mesh that needs to be removed and separated from the Heating Eleme...

Страница 5: ...re a Relay Contactor or Power Module s in addition to the control device to operate properly The Relay or the Power Modules may be located in the same vicinity as the control device If your system wil...

Страница 6: ...is indicated on the Installation Plan by an arc with an arrowhead By examining the relationship between two panels you will determine the type of turn needed Free Form Free form spaces are filled with...

Страница 7: ...Mesh sits on top of the Heating Element Working around Obstacles Special circumstances will require the Heating Element to circumvent an obstacle The released Heating Element is not needed to fill an...

Страница 8: ...hold the wires onto the probes with your fingers A digital meter is easier to use and strongly recommended It is wise to verify that the batteries of the Ohmmeter are good Set your Ohmmeter to measur...

Страница 9: ...lack Red Copper Ground Black Lead THERMOSTAT 1 2 3 4 5 C O INDIA Made by Thermopads Pvt Ltd for WarmlyYours com Inc ENREGISTRE LISTED C US RADIANT HEATING PANEL UNIT UNITE DE PLANCHER CHAUFFANT ELECTR...

Страница 10: ...the Mudbed in the thin set used to adhere the tiles It is advised to prepare the subfloor as you would for any conventional installation along the Tile Council of America Guidelines Once installed ove...

Страница 11: ...suitable glue or cement based adhesive or thinset mortar to adhere it to the slab If installing in a wet location ensure the slope of the mortar bed is maintained to direct water to the drain pipe Not...

Страница 12: ...henever possible 2 Set tiles as recommended TIP Remove excess thin set that may ooze up between the grout joints with a wet rag toothbrush or sponge while installing the tile in preparation for a clea...

Страница 13: ...n the UL label and on the installation plan The Ohms readings should be within a 15 variance of the Ohm value specified on the UL tag Measure the continuity between core wire and ground wire The readi...

Страница 14: ...ply the Flooring Adhesive glue 1 Apply manufacturer s recommended adhesive as per flooring installation instructions Install Laminate Engineered Wood Flooring 1 Install laminate or engineered wood flo...

Страница 15: ...anty cards Using a hot glue gun secure the cold lead to the mortar bed and over the shower curb In order to minimize tension on the cold lead use an S formation to bring the cold lead over the shower...

Страница 16: ...Ohm resistance of each roll should be measured across the core wires Make sure the probes of the Ohm meter do not touch the sheath wire Make sure you do not touch either of the probe ends with your fi...

Страница 17: ...If a sensor is used indicate its location on the plan The electrician should put the code labels UL from any Heating Roll used in a convenient place such as the circuit breaker box The labels should h...

Страница 18: ...must be electrically grounded and protected by a GFI Ground Fault Interrupter 4 The installation must comply with all national and local electrical and building codes as well as any other applicable...

Страница 19: ...INESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 77 LONG GROVE IL WarmlyYours Inc 590 Telser Rd Ste B Lake Zurich IL 60047 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRES...