background image

Important General Considerations

IMPORTANT INFORMATION

The most important consideration is to maintain the 

integrity of the Heating Element; following these simple 

rules can easily do this:

1. NEVER CUT the Heating Element.
2. NEVER CUT the Heating Roll(s) to make it shorter.
3.  NEVER fold or position the Heating Element so that it 

overlaps itself or other wires. The heating portion of the 

heating device set shall not touch, cross over, or overlap 

itself. This will cause dangerous overheating.

4.  NEVER run the Cold Lead Wires or Sensor Wire across the 

Heating Element.

5.  NEVER place built-in cabinets and other furniture with solid 

bases on the heated portion of the floor.

6.  ALWAYS make sure the system is inspected and the Ohms 

tested before, during and after installation.

7.  ALWAYS make sure everyone involved in the installation is 

aware of the care needed to protect the Heating Element 

from damage.

8.  ALWAYS maintain consistent spacing when positioning the 

Heating Element.

9.  NEVER connect two Heating Rolls to each other (in series).  

Only connect them in parallel to the same control device.

10.  Tiles will only be warm where the heating wire is installed. 

If there is no heating wire directly under the area, it will not 

be warm. 

11. A dedicated circuit is recommended for the system.

Note for the System Installer

Provide the homeowner with a copy of the Installation Plan provided to 

you by WarmlyYours.

This will help you and future owners of the home. The plan should indicate where the 

WarmlyYours  Heating  Roll(s)  is  installed,  the  location  of  the  control  device  and  the 

amperage of the system. If a sensor is used, indicate its location on the plan. The electrician 

should put the code labels (UL) from any Heating Roll used in a convenient place such as 

the circuit breaker box. The labels should have Ohm resistance readings written on them. 

These are a useful reference for future inspections and possible troubleshooting. 

Complete the Warranty Card and return to WarmlyYours within 90 days.

Keep your plan and this installation manual safe for future reference.

Record your installation information here:

Name/Company of Electrician ______________________________________________

Address _______________________________________________________________

Tel.# __________________________________________________________________

Location of UL labels _____________________________________________________

Name/Company of Floor Installer ___________________________________________

Address _______________________________________________________________

Tel.# __________________________________________________________________

Location of Installation Plan ________________________________________________

Date of installation _______________________________________________________

The instructions in this manual must be observed when installing the WarmlyYours Floor 

Heating System. Failure to follow these instructions may inhibit optimal performance of 

your Floor Heating System and void the system warranty. A tile-setter, flooring contractor 

or  qualified  Do-It-Yourselfer  can  install  the  WarmlyYours  Heating  Roll(s).  However,  a 

qualified electrician must complete the electrical connections of the system to the main 

electrical circuit in accordance with the National Electrical Code and your local codes. We 

trust that your installation goes well and that you enjoy your warm floors!

16

Содержание TempZone

Страница 1: ...1 1 Free Design Service 24 7 Installation Support No Nonsense Warranty 800 875 5285 www WarmlyYours com Installation Manual for your TempZone Electric Radiant Floor Heating System Twin Conductor...

Страница 2: ...ted surface temperatures and lower energy usage The floor will have the capacity to warm to a comfortable temperature and in some cases can be employed as the primary heat source for that room Securin...

Страница 3: ...Electrical Housing Boxes Switch Plates All control devices except a Relay Contactor fit into a double gang box If a double gang box is used it will need to be fitted with a single gang mud ring We str...

Страница 4: ...to continue in a new direction See Page 5 for full details on how to execute turns F Free Form Space Indicates a length of Fiberglass Mesh that needs to be removed and separated from the Heating Eleme...

Страница 5: ...re a Relay Contactor or Power Module s in addition to the control device to operate properly The Relay or the Power Modules may be located in the same vicinity as the control device If your system wil...

Страница 6: ...is indicated on the Installation Plan by an arc with an arrowhead By examining the relationship between two panels you will determine the type of turn needed Free Form Free form spaces are filled with...

Страница 7: ...Mesh sits on top of the Heating Element Working around Obstacles Special circumstances will require the Heating Element to circumvent an obstacle The released Heating Element is not needed to fill an...

Страница 8: ...hold the wires onto the probes with your fingers A digital meter is easier to use and strongly recommended It is wise to verify that the batteries of the Ohmmeter are good Set your Ohmmeter to measur...

Страница 9: ...lack Red Copper Ground Black Lead THERMOSTAT 1 2 3 4 5 C O INDIA Made by Thermopads Pvt Ltd for WarmlyYours com Inc ENREGISTRE LISTED C US RADIANT HEATING PANEL UNIT UNITE DE PLANCHER CHAUFFANT ELECTR...

Страница 10: ...the Mudbed in the thin set used to adhere the tiles It is advised to prepare the subfloor as you would for any conventional installation along the Tile Council of America Guidelines Once installed ove...

Страница 11: ...suitable glue or cement based adhesive or thinset mortar to adhere it to the slab If installing in a wet location ensure the slope of the mortar bed is maintained to direct water to the drain pipe Not...

Страница 12: ...henever possible 2 Set tiles as recommended TIP Remove excess thin set that may ooze up between the grout joints with a wet rag toothbrush or sponge while installing the tile in preparation for a clea...

Страница 13: ...n the UL label and on the installation plan The Ohms readings should be within a 15 variance of the Ohm value specified on the UL tag Measure the continuity between core wire and ground wire The readi...

Страница 14: ...ply the Flooring Adhesive glue 1 Apply manufacturer s recommended adhesive as per flooring installation instructions Install Laminate Engineered Wood Flooring 1 Install laminate or engineered wood flo...

Страница 15: ...anty cards Using a hot glue gun secure the cold lead to the mortar bed and over the shower curb In order to minimize tension on the cold lead use an S formation to bring the cold lead over the shower...

Страница 16: ...Ohm resistance of each roll should be measured across the core wires Make sure the probes of the Ohm meter do not touch the sheath wire Make sure you do not touch either of the probe ends with your fi...

Страница 17: ...If a sensor is used indicate its location on the plan The electrician should put the code labels UL from any Heating Roll used in a convenient place such as the circuit breaker box The labels should h...

Страница 18: ...must be electrically grounded and protected by a GFI Ground Fault Interrupter 4 The installation must comply with all national and local electrical and building codes as well as any other applicable...

Страница 19: ...INESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 77 LONG GROVE IL WarmlyYours Inc 590 Telser Rd Ste B Lake Zurich IL 60047 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRES...

Отзывы: