background image

14 June 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm 

11 

GENERAL NOTES

 

NOTES: 

 

 

These installation and operating instructions should be kept in a safe place.  Should you require another 

 

copy, download from the 

Warmington

 website www.warmington.co.nz 

 

This appliance must be installed in accordance with the manufacturer’s written instructions to comply with 

 

 the 

Warmington

 warranty. 

 

The appliance and flue system must be installed in accordance with relevant standards and the  

 

appropriate building codes. 

 

This appliance must be serviced annually and any service operation must be carried out by a qualified  

 

service person. 

 

WARNINGS: 

 

 

WARNING;  ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT  BEEN  

  

APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED A   

 BREACH OF NZ STANDARDS. 

 

 

WARNING; DO NOT USE OR STORE FLAMMABLE LIQUIDS OR AEROSOLS IN THE 

  VICINITY   OF THIS APPLIANCE WHILST IN OPERATION.

 

 

 

WARNING;  DO NOT PLACE FLAMMABLE MATERIALS ON OR AGAINST THIS 

 

  

APPLIANCE.

 

 

 

CAUTION

:  THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL 

  TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.

 

 

 

CAUTION:  

ALL SERVICING MUST BE CARRIED OUT BY AN AUTHORISED SERVICE 

  TECHNICIAN. 

 

 

CAUTION:  

MAKE SURE THE USE OF CORRECT FUEL TYPE WITH THIS APPLIANCE. 

NOTE: Keep a copy of these instructions for operating and 

maintenance guidelines.  

 

Industries 1994 LTD 

PO Box 58652, Botany 2163, Auckland 

www.warmington.co.nz

  

Содержание SG 700

Страница 1: ...ion The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in your...

Страница 2: ...on the pressure difference from inside the building to the outside A lower pressure in the building may induce a draft down the flue system and back into the building causing the fire to smoke or spil...

Страница 3: ...rner Width A 674 754 874 1074 Burner Height B 205 205 205 205 Burner Depth C 272 272 272 272 Flue Diameter Min J 200 200 250 250 Flue CSA mm K 31 416 31 416 49 087 49 087 WARMINGTON BURNERS NOTE IMPOR...

Страница 4: ...ctor Size mm 2 X 1 1mm 2 X 1 2mm 2 X 1 3mm 2 X 1 4mm Burner Pressure High kPa 2 5 2 5 2 5 2 5 Burner Pressure Low kPa 0 75 0 75 0 75 0 75 MJ h 29 38 42 50 Flame Effect Output Only Effect Effect Effect...

Страница 5: ...hat the Gas Type Specified on the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation...

Страница 6: ...roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals Logs may vary to make an even Flame Pattern Logs and Twigs may be scattered to achie...

Страница 7: ...ng the Switch in a Depressed State repeat steps 2 3 if necessary Once the Pilot Flame is lit hold this position for 3 5 seconds release from the Depressed State before setting the Flame Control to Ful...

Страница 8: ...rol Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the Test Ga...

Страница 9: ...es on the principle of dual radiant and convected heat Therefore it is important to observe the following precautions associated with any heating appliance or open fire Do not cover or restrict the fi...

Страница 10: ...adjust to Low Flame and check pres sure NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment S...

Страница 11: ...serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AU...

Отзывы: