FR
PG
15

W415-1632 / A / 05.02.16

INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.

NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.

INSTALLATION AND 

OPERATING INSTRUCTIONS

1.22D

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 

103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone (705)721-1212 • Fax (705)722-9081 • www.napoleonfi replaces.com • [email protected]

SAFETY INFORMATION

!

WARNING

If the information in these instructions are 
not followed exactly, a fi re or explosion 
may result causing property damage, 
personal injury or loss of life.

- Do not store or use gasoline or other fl ammable 
vapors and liquids in the vicinity of this or any 
other appliance.

- WHAT TO DO IF YOU SMELL GAS:
• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use        
any phone in your building.

• 

Immediately call your gas supplier from a        
neighbour’s phone.  Follow the gas supplier’s        
instructions.

• 

If you cannot reach your gas supplier, call the        
fi re department.

- Installation and service must be performed by a 
qualifi ed installer, service agency or the supplier.

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

$10.00

HOT GLASS 

WILL CAUSE 

BURNS

.

DO NOT TOUCH 

GLASS UNTIL 

COOLED

.

NEVER 

ALLOW CHILDREN TO 

TOUCH GLASS

.

!

DANGER

A barrier designed to reduce the risk of burns from 
the hot viewing glass is provided with this appliance 
and shall be installed for the protection of children 
and other at-risk individuals.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used.

Decorative Product: Not for use as a heating appliance.

CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.

HDX52

LOG BURNER

ASSEMBLY

B52NTL

NATURAL GAS

B52PTL

PROPANE

Summary of Contents for HDX52

Page 1: ...ghbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier CERTIFIED FOR CANADA AND UNITED STATES USING ANSI CSA METHODS 10 00 HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS DANGER A barrier design...

Page 2: ...nce 1 0 GENERAL INFORMATION 2 0 INSTALLATION 2 1 ACCESS PANEL 2 2 BURNER ASSEMBLY 1 0 GENERAL INFORMATION 2 2 0 INSTALLATION 2 2 1 ACCESS PANEL 2 2 2 BURNER ASSEMBLY 2 2 3 BULKHEADS 3 2 4 HEARTH PANEL INSTALLATION 4 2 5 HEARTH LOG LOG PLACEMENT 5 2 6 CHARCOAL LUMPS 7 2 7 CHARCOAL EMBERS 7 2 8 VERMICULITE 8 2 9 GLOWING EMBERS 8 3 0 ADJUSTMENT 8 3 1 FLAME CHARACTERISTICS 8 3 2 VENTURI ADJUSTMENT 8 4...

Page 3: ... Connection Pilot Tube Gas Connection Pilot Electrode Lead Bulkhead 2 3 BULKHEADS B Connect the pilot electrode lead to the bulkhead matching the 3 16 flag with the 3 16 bulkhead spade Do the same with the 1 4 spark lead to the 1 4 bulkhead spade C Ensure the venturi tubes are over the orifice before lighting D Check for gas leaks by brushing on a soap and water solution Do not use open flame E Af...

Page 4: ...When shipped the hearth panels range in varying shades of Sandstone New Port During initial use the panels will darken temporarily The appearance of the panels will permanently lighten in color with use INSTALL HEARTH FLOOR PANELS ACCORDING TO THE INSTALLATION LEAFLET 2 4 HEARTH PANEL INSTALLATION NOTE It is recommended to remove the grate assembly prior to panel installation 4 W415 1632 A 05 02 1...

Page 5: ... in the top of the bottom rear log C Align the 2 holes in the bottom in the middle log with the studs located on the front log support D Align the hole in the rear left log with the left pin of the top rear log A B C D E Line the notches in the bottom of the front right log with the 4th and 5th grate posts Make sure not to cover ports F Line the notch in the front left log with the front left corn...

Page 6: ...he bottom rear log and the front right log pushing back against the rear panel J Align the hole and the pin in the right crossover log with the pin in the top rear log and the hole in the top right log K Place the notch in the front charcoal log over the second grate post Make sure not to cover any ports L Align the pin in the bottom of the middle crossover with the hole in the middle of the middl...

Page 7: ...L EMBERS VERMICULITE AND CHARCOAL LUMPS ARE NOT TO BE PLACED ON THE BURNER 2 7 CHARCOAL EMBERS 32 1 Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner Fine dust found in the bottom of the bag should not be used NOTE Charcoal embers are not to be placed on the burner 7 W415 1632 A 05 02 16 EN ...

Page 8: ...m your Authorized dealer 3 0 ADJUSTMENT 3 1 FLAME CHARACTERISTICS 3 2 VENTURI ADJUSTMENT This appliance has air shutters that have been factory set open according to the chart below Regardless of venturi orientation closing the air shutter will cause a more yellow flame but can lead to carbonization Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner po...

Page 9: ...TS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING 11 ITEMS MAY NOT APPEAR EXACTLY AS ILLUSTRATED REF NO PART NUMBER DESCRIPTION 1 W010 3821 W010 3858 W135 0630 W135 0631 W135 0634 W135 0635 W135 0632 W135 0633 FOR REPLACEMENT PARTS REFER TO 1 1 1 1 1 1 1 1 LOG REAR TOP LOG MIDDLE LOG FRO...

Page 10: ...CKET PILOT SHIELD W010 3849 ASSY TUBE BURNER WELDMENT W080 1646 BRACKET VENTURI N255 0002 FITTING UNION BULKHEAD 3 8 MF TO 3 8MF W432 0540 MANIFOLD W385 1908 LABEL MEDIA WARNING W665 0029 TAG BURNER ASSEMBLY B52 W456 0031 60 BURNER ORIFICE 31 W456 0026 60 BURNER ORIFICE 26 W450 0050 NUT 5 8 18 UNF JAM NUT REF NO 11 12 13 14 15 16 17 18 19 PART NUMBER DESCRIPTION 1 2 3 4 5 6 7 8 9 10 REF NO PART NU...

Page 11: ...IGH TEMP 3 WAY W655 0772 SUPPORT LOG W010 3823 ASSY LOG SUPPORT W080 1645 BRACKET PILOT SHIELD W010 3849 ASSY TUBE BURNER WELDMENT W080 1646 BRACKET VENTURI N255 0002 FITTING UNION BULKHEAD 3 8 MF TO 3 8MF W432 0540 MANIFOLD W385 1908 LABEL MEDIA WARNING W665 0029 TAG BURNER ASSEMBLY B52 W456 0053 60 BURNER ORIFICE 53 W456 0047 60 BURNER ORIFICE 47 W450 0050 NUT 5 8 18 UNF JAM NUT REF NO 11 12 13 ...

Page 12: ...12 W415 1632 A 05 02 16 EN 44 1 6 0 NOTES ...

Page 13: ...13 W415 1632 A 05 02 16 EN 44 1 6 0 NOTES ...

Page 14: ...MT t 8PPE 4UPWFT FBUJOH PPMJOH t MFDUSJD JSFQMBDFT t 0VUEPPS JSFQMBDFT t BT SJMMT JSFQMBDFT FBUJOH PPMJOH DBMM t SJMMT DBMM napoleonproducts com BQPMFPO 3PBE BSSJF 0OUBSJP BOBEB BZWJFX SJWF BSSJF 0OUBSJP BOBEB JMMFS SJWF SJUUFOEFO FOUVDLZ 64 5SBOT BOBEB JHIXBZ POUSFBM 2VFCFD BOBEB 5 ...

Page 15: ...utre appareil QUE FAIRE SI VOUS DÉTECTEZ UNE ODEUR DE GAZ N allumez aucun appareil Ne touchez à aucun interrupteur électrique n utilisez aucun téléphone dans votre immeuble Appelez immédiatement votre fournisseur de gaz d un téléphone voisin Suivez ses instructions Si vous ne pouvez pas rejoindre votre fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être f...

Page 16: ...tonome ou avec n importe quel autre appareil 1 0 INFORMATION GÉNÉRALE 2 0 INSTALLATION 2 1 ASSEMBLAGE DU BRÛLEUR 1 0 INFORMATION GÉNÉRALE 16 2 0 INSTALLATION 16 2 1 ASSEMBLAGE DU BRÛLEUR 16 2 2 RACCORDS 17 2 3 INSTALLATION DES PANNEAUX DE PLANCHER 18 2 4 DISPOSITION DES BÛCHES 19 2 5 MORCEAUX DE CHARBON 21 2 6 BRAISES DE CHARBON 21 2 7 VERMICULITE 22 2 8 BRAISES INCANDESCENTES 22 3 0 RÉGLAGES 22 3...

Page 17: ...accords de gaz Raccord de veilleuse 2 2 RACCORDS B Branchez les fils d électrode de la veilleuse au raccord en faisant correspondre l embout femelle de 3 16 à l embout mâle de 3 16 Faites de même avec le 1 4 bougie à la 1 4 cloison pelle C Assurez vous que les tube de venturi est par dessus les injecteur avant d allumer Raccord Fils d électrode de veilleuse D Vérifiez pour des fuites de gaz en app...

Page 18: ...anneaux pour les mettre en place La couleur des panneaux expédiés varie de différentes teintes de grès Lors de l utilisation initiale les panneaux fonceront de façon temporaire pour ensuite pâlir de façon permanente à l usage POUR INSTALLER PANNEAUX DE PLANCHER REPORTEZ VOUS À LA INSTALLATION INSTRUCTIONS 2 3 INSTALLATION DES PANNEAUX DE PLANCHER NOTE Nous vous suggérons de enlever l ensemble de l...

Page 19: ...s les trous sur le dessus de la bûche inférieure arrière C Alignez les deux trous du dessous de la bûche centrale sur les goujons situés sur le support à bûches avant D Alignez le trou dans la bûche arrière gauche sur la tige gauche de la bûche supérieure arrière A B C D E Alignez les encoches en dessous de la bûche avant droite sur les quatrième et cinquième barreaux du chenet Prenez soin de ne p...

Page 20: ...ure arrière et de la bûche avant droite appuyée sur le panneau arrière J Alignez le trou et la tige de la bûche transversale droite avec la tige dans la bûche supérieure arrière et le trou de la bûche supérieure droite K Placez l encoche de la bûche de charbon de bois avant au dessus du deuxième barreau du chenet Prenez soin de ne pas couvrir les orifices L Alignez la tige du dessous de la bûche t...

Page 21: ...MENT LES BRAISES DE CHARBON DE BOIS LA VERMICULITE ET LES MORCEAUX DE CHARBON NE DOIVENT PAS ÊTRE PLACÉS SUR LE BRÛLEUR 2 6 BRAISES DE CHARBON 32 1 Éparpillez les braises à l avant et sur les côtés du support à bûches de façon à créer un effet réaliste N utilisez pas la fine poussière qui reste au fond du sac NOTE Les braises de charbon de bois ne doivent pas être placées sur le brûleur ...

Page 22: ...ez que des braises incandescentes et des bûches PhazerMD disponibles chez votre détaillant autorisé 3 0 RÉGLAGES 3 1 CARACTÉRISTIQUES DE LA FLAMME 3 2 RÉGLAGE DU VENTURI Il est important d effectuer périodiquement une inspection visuelle de la flamme de la veilleuse et du brûleur Comparez les à ces illustrations Si des flammes paraissent anormales contactez un technicien de service 54 2A 3 8 1 2 9...

Page 23: ...S DE BRÛLEUR ASSEMBLAGE PL W010 3858 1 4 0 RECHANGES Contactez votre détaillant ou le fabricant pour les questions concernant les prix et la disponibilité des pièces de rechange Normalement toutes les pièces peuvent être commandées chez votre détaillant autorisé POUR UN REMPLACEMENT DE PIÈCE SOUS GARANTIE UNE PHOTOCOPIE DE LA FACTURE ORIGI NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE Lorsq...

Page 24: ...DE VEILLEUSE W010 3849 ASSEMBLAGE TUBE BRÛLEUR WELDEMENT W080 1646 SUPPORT VENTURI N255 0002 RACCORD TRAVERSANT 3 8 MF TO 3 8MF W432 0540 COLLECTEUR W385 1908 ÉTIQUETTE MEDIA AVERTISSEMENT W665 0029 ÉTIQUETTE ASSEMBLAGE DE BRÛLEUR B52 W456 0031 INJECTEUR DE VEILLEUSE 60 31 INJECTEUR DE VEILLEUSE 60 26 W456 0026 W450 0050 ÉCROU 5 8 18 CONTRE ÉCROU UNF REF NO 11 12 13 14 15 16 17 18 PART NUMBER DESC...

Page 25: ...R DE VEILLEUSE W010 3849 ASSEMBLAGE TUBE BRÛLEUR WELDEMENT W080 1646 SUPPORT VENTURI N255 0002 RACCORD TRAVERSANT 3 8 MF TO 3 8MF W432 0540 COLLECTEUR W385 1908 ÉTIQUETTE MEDIA AVERTISSEMENT W665 0029 ÉTIQUETTE ASSEMBLAGE DE BRÛLEUR B52 W456 0053 INJECTEUR DE VEILLEUSE 60 53 INJECTEUR DE VEILLEUSE 60 47 W456 0047 W450 0050 ÉCROU 5 8 18 CONTRE ÉCROU UNF REF NO 11 12 13 14 15 16 17 18 PART NUMBER DE...

Page 26: ...26 W415 1632 A 05 02 16 FR 5 0 NOTES 44 1 ...

Page 27: ...27 W415 1632 A 05 02 16 FR 5 0 NOTES 44 1 ...

Page 28: ...FBV 1PÐMFT Ë CPJT t 1SPEVJUT 7 t PZFST ÏMFDUSJRVFT t PZFST FYUÏSJFVST t SJMT Ë HB EF RVBMJUÏ PZFST IBVGGBHF FU MJNBUJTBUJPO SJMT DPNQPTF napoleonproducts com 3PVUF 5SBOTDBOBEJFOOF POUSÏBM 2VÏCFD 5 BQPMFPO 3PBE BSSJF 0OUBSJP BOBEB BZWJFX SJWF BSSJF 0OUBSJP BOBEB JMMFS SJWF SJUUFOEFO FOUVDLZ 64 ...

Reviews: