3.3. TROUBLE SHOOTING

3.3.1. Error Code Table

3.4. RECOMMENDATIONS FOR ECONOMICAL USE 

OF THE BOILER

Your boiler is set in ECO mode for economical use, it is not 

recommended to change this setting.

Selection of Right Capacity

Heat loss of the ambient where the boiler is to be used shall be 

properly calculated, and boiler capacity shall be set accordingly. 

Appliances not having sufficient capacity will respond to demand more 

slowly, and appliances with higher capacities will lead to discomfort and 

more fuel consumption as they will be activated and deactivated more 

frequently. Therefore, suitable boiler capacity for the ambient to be 

heated. 

Insulation

Insulation of your building is the most important factor preventing 

heat loss and reducing gas consumption. In addition, the insulation of 

your boiler is the thickest insulation within its class, thus heat loss is 

minimized.

Radiators

Adjust the radiator valves to balance pressure distribution of the system 

in your house. Placing furniture in front of radiators causes discomfort 

and higher fuel consumption. Reducing radiator valves or turning into 

the lowest position (thermostatic radiator valves) for the rooms which 

are not used for a long term, provides energy-saving. 

Hot Domestic Water

If you are using the boiler with a hot domestic water boiler, it is 

recommended to set the Hot Domestic Water temperature as (38~42 

°C). Setting the water heater to a low value provides a large amount of 

energy saving.

Thermostatic Radiator Valves 

Use of Thermostatic Radiator Valves ensures balancing thermal 

distribution within your house, thus provides energy saving and comfort.

Room thermostats 

Room thermostats allow setting ambient temperature for comfort and 

economic times, thus your boiler will operate more economically. Thus 

you can set your room temperature as you want, and make energy 

saving by 6% with each degree reduction.

Ventilation

Do not leave the windows half-open to ventilate room(s). In this case, 

while there will be no significant improvement in the room air quality, a 

continuous heat loss will take place. Opening windows fully for a short 

term gives more effective results.

Turn the thermostatic Radiator Valves to the lowest position when 

ventilating rooms.

3.5. MATTERS TO PAY ATTENTION FOR GUARANTEE 

CONDITIONS 

This warranty provided by WARMHAUS does not include fixing or 

eliminating faults caused by use of the appliance for purposes other 

than intended use as well as the conditions specified below:

1.

  Damages and faults of the appliances start-up of which was not 

carried out by Warmhaus Authorized Service,

2.

  Damages and faults caused by improper use of the appliance and 

noncompliance with the terms and instructions in the Operation 

Manual,

3.

  Damages and faults caused by wrong selection of type,

4.

  Damages and faults caused by maintenance and reparation carried 

out by persons other than our Authorized Service,

5.

  Damages and faults caused by transport, unloading, loading, 

storage, external impact (crush, scratch, etc.) and chemical factors 

after delivery of the product,

6.

  Damages and faults caused by fire and lightning stroke,

7.

  Damages and faults caused by use of incompatible fuel and fuel 

properties,

8.

  Excessive or low voltage; use of unearthed socket; damages and 

faults occurred in the faulty electrical installation,

9.

  Annual maintenance and cleaning which must be carried out by 

our Authorized Service,

10.

  Damages and faults caused by nonperformance of prescribed 

periodical maintenance,

11.

  Damages and faults occurred in the appliance or place of use due 

to other products and accessories used within the system together 

with the appliance subject to warranty.

12.

  Damages and faults caused by frost/freezing or use in areas 

exposed to atmospheric conditions (e.g. Open balcony, etc.).

13.

  Alteration of Registration Plate and Warranty Certificate,

14.

  Damages and faults caused by use of water out of values specified 

in the operation manual of the appliance,

YReparation or elimination of faults specified below shall be charged.

The warranty applies only within the period specified on the reverse 

side of this certificate and for the faults occurred only on the appliance. 

Dear Customers, we believe in importance of providing high quality 

after sales services as well as a good product. Therefore, you can 

obtain information and contact our company in case of any service 

needs by calling;

Obligatory Recommendations and Important Information:
1.

  Preserve the technical service voucher provided by the Authorized 

Service for start-up of the boiler, a copy of the invoice of the 

appliance and the Warranty Certificate certified by Authorized 

Dealer.

2.

  Use your appliance in compliance with installation and operation 

manual.

30

Содержание VIWA 50

Страница 1: ...WALL MOUNTED CONDENSING BOILERS INSTALLATION USER MANUAL VIWA50 VIWA65...

Страница 2: ...Viwa 50 Viwa 65...

Страница 3: ...5 Use Of Split Flue Type Hermetic 2 2 16 Installation At Partially Protected Outsides 2 2 17 Electrical Connections 2 2 18 Optional Controls Room Thermostat Outside Temperature Sensor And Others 2 3 H...

Страница 4: ...ed boiler Only APPROVED ORIGINAL spare parts should be used Bolts sealed with paint strictly forbidden to open The boiler must not be used by children younger 8 years or invalid persons without superv...

Страница 5: ...Lawa Plus 150 11 606 000001 0 3 mm 30 120 mm 0 2 mm 6 30 mm mza E B NER TA DEM R Logo Kodu Aksi belirtilmeyen genel tolerans i in ISO 2768 M ge erlidir 0 8mm 400 1000 mm 0 5mm 120 400 mm 0 125 mm 3 6...

Страница 6: ...r G25 Not Approved Approved Approved Not Approved BE FR YES I 2L Natural Gas 25 mbar G25 Not Approved Approved Approved Not Approved NL YES I 2ELL Natural Gas 20 mbar G20 Not Approved Approved Approve...

Страница 7: ...boiler is to be mounted over the kitchen countertop or kitchen set there shall be a minimum 50 cm distance under the boiler Due to possibility of water draining from the Safety Valve of the boiler aft...

Страница 8: ...e carefully controlled and will impact the boiler strength Ensure that gas valve connection is correct Flammable gas supply pipe should be able to supply correct adequate gas amount to the boiler when...

Страница 9: ...and is thoroughly vented Check that the circulating pump is not jammed Purge the system bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas valve inlet 2 1...

Страница 10: ...esh Air Intake with Split Flue Sets Air Exhaust Gas B23 C13 Figure 10 Hermetic Concentric and Flue Split Flue type 2 1 10 Peripheral Distances of the Flue Outlet Connections For positioning of the flu...

Страница 11: ...m 32 C at mid level 1 5 m above the floor level 40 C at ceiling level 0 100 mm from ceiling When installed as a class B appliance open flued not roomed sealed Installed in a room High level within 15...

Страница 12: ...pe shall be secured with dowels and bracelets with 3 meter intervals 1 90 bend 2 Sealing ring 3 Sealing ring 4 Centering wire 5 External flue pipe 6 Inner wall flange 7 Outer wall flange 8 External fl...

Страница 13: ...end equivalent length L5 1 0 m L6 2 0 m L Total 6 3 m 6 3 m Lmax 11 m It is correct in implementation Implementation L1 0 5 m L2 1 0 m 90 bend equivalent length L3 1 5 m L4 1 0 m 90 bend equivalent le...

Страница 14: ...e L 500 mm 153 11 660 600026 80 125 Extension Flue L 1000 mm 153 11 660 600027 80 125 Extension Flue L 1500 mm 153 11 660 600028 80 125 Extension Flue L 2000 mm 153 11 660 600029 80 125 Bend 45 153 11...

Страница 15: ...individual in accordance with directives and standards in force in the country where the boiler is installed Also ensure that the electricity installation complies with the maximum power to be supplie...

Страница 16: ...r drainage of water into to the installation place when the safety valve is enabled 2 2 3 Drainage of the Condensate Water The appliance shall be connected to the drainage water network through pipes...

Страница 17: ...drainage pipe outlet Open air flusher Figure 32 Outside Connection of Condensate Water Drainage Pipe SECTION 2 INS Outdoor flusher Condensate Water Drainage Pump Refer to detailed instructions of the...

Страница 18: ...te exchanger at least one expansion tank must be placed in the return line of the cascade side and the return line of the heating system side Filter elements strainers must be fitted to return line of...

Страница 19: ...ection 3 x 1 0 mm 2 2 Boiler Slave 1 Boiler Master 6 Boiler Slave INSTALLATION EQUIPMENT 1 Boiler 2 Gas Safety Solenoid Valve 3 Ball Valve 4 Gas Filter 5 Vibration Isolator 6 Condensate Water Siphon a...

Страница 20: ...s and eventual copies The content of this document is Bertelli Partners s r l s property You must not be copy or use it in whole or in part without a prior written consent by Bertelli Partn 0 MLC27 1...

Страница 21: ...ture Sensor with Cable It is the sensor that notifies the maximum flow water temperature by measuring the outside air temperature It is necessary to use one for fuel economy in single boiler or cascad...

Страница 22: ...ler heating and domestic hot water Leave the boiler in Stand by OFF on the display position thus Anti Frost Function will be enabled Turn off the boiler during maintenance and repair operations near t...

Страница 23: ...oiler operates only for domestic hot water in this mode if a boiler is fitted To switch to domestic water position 3 2 4 Resetting the Boiler Restart When the appliance shows fault blocking error push...

Страница 24: ...set with no 7 and 8 buttons and this temperature is shown on this display with no 10 indicator for Heating system and no 12 indicator for Hot Domestic Water Turning off the Boiler To turn off the boil...

Страница 25: ...to the curves given below After connecting the Outside Temperature Sensor by means of the P04 parameter It is adjusted according to average outside temperature of your province This setting will be p...

Страница 26: ...ton and check if problem is solved 2 Check if the boiler heating system valves are open if not open all of them 3 Check if all radiator valves are open if not open minimum 3 meter radiators must be on...

Страница 27: ...ed 2 Check if the boiler heating system valves are open if not open all of them 3 Check if all radiator valves are open if not open minimum 3 meter radiators must be on 4 Restart the boiler by pushing...

Страница 28: ...e authorized service if fault remains unsolved E 79 Minimum regulating current value is reached The boiler does not operate E79 error code blinks Gas Supply Pressure Wearing or corrosion of electrode...

Страница 29: ...ode position Burning calibration Gas valve fault Electronic board 1 Call the authorized service first 2 Check for false flue OR flue gas clogging 3 Restart the boiler by pushing RESET button 2 Call Au...

Страница 30: ...TION FOR GUARANTEE CONDITIONS This warranty provided by WARMHAUS does not include fixing or eliminating faults caused by use of the appliance for purposes other than intended use as well as the condit...

Страница 31: ...n max C 25 47 25 47 Operating Pressure Maximum bar 4 4 Operating Pressure Minimum bar 0 5 0 5 Temperature Setting Range Temperature Setting Range C 35 60 35 60 Electrical Circuit Power Supply V AC 50...

Страница 32: ...t and high temperature regime 2 4 88 87 8 Useful efficiency at 30 of rated heat output and low temperature regime 1 1 97 11 97 39 Auxiliary Electricity Consumption Full load elmax kW 0 09 0 10 Part lo...

Страница 33: ...IP X5D GC NO Gas Categories G20 Maximum heat input Qn kW 50 Minimum heat input Qn kW 6 5 t 80 60 Maximum heat output Pn kW 48 7 Minimum heat output Pn kW 5 69 B 23 C 13 C 33 C 53 C 63 C 83 I2H I2E I2E...

Страница 34: ...s IP X5D GC NO Gas Categories G20 Maximum heat input Qn kW 65 Minimum heat input Qn kW 8 t 50 30 Maximum heat output Pn kW 63 2 Minimum heat output Pn kW 7 29 B 23 C 13 C 33 C 53 C 63 C 83 I2H I2E I2E...

Страница 35: ...50 61 Viwa 50 65 58 Viwa 65 35 35...

Страница 36: ...VIWA50 VIWA65 WALL MOUNTED CONDENSING BOILERS INSTALLATION AND USER MANUAL VIWA 50 VIWA 65 Montaj Kullan m K lavuzu kodu 150 11 606 000037 Revizyon numaras R02 05 10 2018...

Отзывы: