2.1.4. Operation in Summer Mode
Boiler only operates for heating the domestic hot water in this mode. In
order to switch to summer mode;
{If you have a ground heating system, as our Authorized
Service adjust your combi for
“Low Temperature Operation”
,
maximum temperature shall be limited with the Radiator
temperature adjustment button (3) (e.g. maximum 47 °C)}.
Domestic Hot Water Adjustment at Winter
Position; First press the DHW button (4).
At that position,
symbol flashes at right
top corner of the screen and existing DHW
temperature will be seen on the screen and
screen light will turn off.
You can adjust the hot tap water temperature
value between 35 – 60 °C with (14) and (15)
numbered buttons. Screen lights during
temperature change, °C symbol flashes
besides the DHW temperature value. Screen
light turns off after adjustment.
If you are starting the combi for the first time
hold
MODE
button, and release the button
after the cycle is completed on the screen,
initially combi switches to radiator position,
its symbol
will flash on left top corner
of the screen existing radiator installation
temperature shall be indicated on the screen
and screenlight will be turned-off.
In order to switch to DHW position, hold
MODE
button and release the button after
completion of cycle on the screen. At that
position,
symbol flashes at right top corner
of the screen and existing DHW temperature
will be seen on the screen and screen light will
turn off.
At that position
, you can adjust the
temperature between 35 – 60 °C with the
Domestic Hot Water temperature adjustment
button (4). Screen light will be open during
adjustment, tap symbol
and Domestic
Hot Water temperature value will flash. You
can adjust the hot tap water temperature
value between 35 – 60 °C with (14) and (15)
numbered buttons. Screen lights during
temperature change, °C symbol flashes
besides the DHW temperature value. Screen
light turns off after adjustment.
2.1.5. Shutting off the Boiler
To set the boiler to OFF position while it is in SUMMER position;
When the
MODE
button is hold, after the cycle is
completed while screen light is on,
screen will display
OFF
letter, that means your
combi is OFF.
OFF
To bring combi in
OFF
position while it is in
WINTER
; hold
MODE
button, after cycle is
completed while the screen light is on, combi
will be in
SUMMER
position.
When combi is started, flame modulation symbol is seen at the middle section
of the screen. At that position, you can increase (3+14)
and decrease
(3+15)
the temperature with radiator temperature adjustment buttons
(see. Figure 47-48) (3) between 25 – 80 °C, screen lights when buttons are
pressed and °C symbol
flashes besides the radiator temperature value.
Now, your combi is at
STANDBY
position as
OFF
.
OFF
Then, upon repeating the same operation, letter
will be displayed on screen after completing the
cycle and screen light turns off.
Analogue manometer is located near to right-bottom side of the
combi. Installation pressure should be seen in this manometer even
in the absence of electricity.
{If you have a ground heating system, as our Authorized
Service adjust your combi for
“Low Temperature Operation”
,
maximum temperature shall be limited with the Radiator (CH)
temperature adjustment button (3) (e.g. maximum 50 °C)}.
Содержание EWA 2525C
Страница 1: ...CONDENSING COMBI BOILERS USER MANUAL EWA 2525C EWA 2530C...
Страница 19: ...19 warmhaus co uk...