2.2. USE WITH ROOM THERMOSTAT (OPTIONAL)
This product can be used together with a room thermostat which can be
purchased separately as an accessory. All Warmhaus thermostats can be
connected with dual-wired cables. Carefully read user’s and installation
instructions given in the Accessory set. When connected to a room
thermostat, the appliance can be operated based on requested room
temperature. With certain models of control units, you may run your boiler
on a daily / weekly programme.
General Utilisation Type
• Please consult our authorised services for room thermostats compatible
with Warmhaus boilers.
• Do not remove device components during operation.
• Do not place the boiler in a position allowing direct sunlight exposure or
near heat sources.
• Manufacturer company shall not be responsible for below given
situations:
a) Faulty installation
b) Making intervention on the device by unauthorised persons
c) Failing to follow instructions given in this book and room thermostat
booklets
Installation instruction:
Device installation shall only be performed by the
Warmhaus Authorised Service. The dual cable required for installation is
supplied by the dealer/consumer.
Maintenance and Service Life:
Warmhaus room thermostat should not
come into contact with water or excessive humidity. Unless an external
damage occurs, the room thermostat does not require any maintenance.
Room thermostat should be installed at 1,50 m height from
ground.
At least 30 cm distance should be available from doors and
windows open for air circulation.
2.3. USE OF OUTSIDE TEMPERATURE SENSOR
(OPTIONAL)
This product can be used together with a Outside Temperature Sensor
which can be purchased separately as an accessory.
When connected to a Outside Temperature Sensor, the appliance runs with
reference to the weater temperature, based on selected heating curve.
Available heating curves are given in figure 5.
Figure 3
Thermostat position
150 cm
Min.
30 cm
Figure 4
Boiler controlled by Outside Temperature Sensor
Figure 5
Heating curves for Outside Temperature Sensor
20,0
30,0
40,0
50,0
60,0
70,0
80,0
-25
-20
-15
-10
-5
0
5
10
15
20
K=0,75
K=1,5
K=2,2
K=3
K=4,5
K=6
K=9
C.H. Flo
w T
emper
atur
e °C
Outside Temperature °C
0016_00.W170323
0093_00.W210702
0018_00.W210309