Error
Code
Error
Fault
Possible Cause
Solution(s)
E 11
Gas valve modulator is not
connected
The boiler does not operate, E11
error code blinks
> Gas valve line
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 12
Hot Domestic Water temperature
fault in summer mode
The boiler does not operate, E12
error code blinks
> Hot Domestic Water
temperature sensor in the
boiler is faulty
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 13
Exhaust Gas Temperature Sensor
excessive temperature alarm
The boiler does not operate, E13
error code blinks
> Excessive gas
temperature outlet value
> 105°C
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 14
Exhaust Gas (FLUE) Temperature
Sensor fault
The boiler does not operate, E14
error code blinks
> Heating system Exhaust
Gas Temperature sensor
is faulty
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 15
Fan fault (feedback/supply)
The boiler does not operate, E15
error code blinks
> Fan system
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 16
Heating temperature RETURN
sensor is faulty
The boiler does not operate, E10
error code blinks
> Heating system RETURN
temperature sensor is faulty
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 17
Temperature difference between
SUPPLY and LIMIT NTC (Dual
Heating Sensor) is faulty
> SUPPLY AND LIMIT
Sensor (dual NTC) is faulty
> SUPPLY AND LIMIT
Sensor (dual NTC) is faulty
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 19
Input measurement of water flow
selection with water flow meter
Inadequate internal heating
water upon demand
Parameters are set
incorrectly on TsP menu
1-) Call the authorized service first
2-) TsP Parameter P01=0 default value must be set only by the
authorized service
E 20
Heating system
Excessive Temperature, Radiator
Heating Temperature > TSP 81
value °C
The boiler does not operate, E81
error code blinks
> Insufficient/no water in
the system
> Pump clogging
> Pump fault
> Pump equipment
> Installation clogging
1-) First restart the boiler by pushing RESET button, and check if
problem is solved
2-) Check if the boiler central heating system valves are open, if
not, open all of them
3-) Check if all radiator valves are open, if not open, minimum 3
meter-radiators must be on
4-) RESET the boiler, and check if the problem is solved
2-) Call Authorized service if the fault remains unsolved.
E 21
Delta Temperature Radiator Heating
supply and Return > TSP 82 value °C
The boiler does not operate, E21
error code blinks
> Insufficient/no water in
the system
> Pump clogging
> Pump fault
> Pump equipment
> Equipment clogging
1-) Restart the boiler by pushing RESET button, and check if
problem is solved.
2-) Check if the boiler heating system valves are open, if not,
open all of them.
3-) Check if all radiator valves are open, if not open, minimum 3
meter-radiators must be on
4-) Restart the boiler by pushing RESET button, and check if
problem is solved.
5-) Call Authorized service if the fault remains unsolved.
E 28
Permitted maximum consecutive
number of resetting is reached
Permitted number of RESET is
reached.
Due to other possible
causes, too many
consecutive blocking
(subsequently resetting)
fault
1-) Disconnect the power supply, and resetting will be permitted
2-) Find the root cause of the error code to solve3-) Call
Authorized service if the fault remains unsolved.
E 37
Abnormal low voltage
The boiler does not operate, E01
error code blinks
Low voltage in < 165 VAC
Electricity mains operation
mode +/- %5 OR in
Automatic calibration mode
< 182 VAC +/- %5
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 40
Incorrect mains frequency
measurement
The boiler does not operate,
E40 error code blinks
Incorrect frequency
measurement, in mains
different than 50 Hz +/-%5
1-) Call the electricity company
2-) If the supplied frequency is 50 Hz +/- %5, the fault will be
solved
E 41
More than 6 consecutive ignition
loss
The boiler does not operate, E41
error code blinks
> Too much domestic water
demand within a short
period (1 minute)
> Low gas pressure
1-) Restart the boiler by pushing RESET button.
2-) Call the authorized service if fault remains unsolved.
E 42
Button failure
The boiler does not operate,
E42 error code blinks
Parameters are set
incorrectly on TsP menu
1-) Call Authorized service if the fault remains unsolved.
E 43
Room thermostat (Opentherm)
communication error
The boiler does not operate,
E43 Error Code blinks on
the display after 1 minute
communication error
Room thermostat
(Opentherm) line
connection interrupted
1-) Cut power of the boiler and E43 will disappear when re-
energized, and the boiler and buttons will be functional 2-)
Replace batteries of the room thermostat with new ones, and
RESET the room thermostat.
3-) Check the cabling between the boiler and thermostat, and fix
any interruptions, no 19 symbol will appear on the display if the
connection is successful 4-) Call authorized service to re-connect
the room thermostat (Opentherm).