3.4 Flue System
The appliance comes with an 80/100mm twin wall flue comprising a 500mm long flue section
and a 500mm long flue terminal.
The supplied flue system is adequate only if the flue terminal is more than 2.3 meters from an
adjacent wall or surface as required by building regulations. If an additional length of flue and
fittings are used, manufacturer’s instructions for correct fastening and support must be followed.
If the flue terminal is to be within 2.3 meters of adjacent walls or surfaces, please refer to Figure
61 – this is provided for guidance only.
Installations must comply with the combustion appliance and fuel storage systems directive of
current local building regulations.
Figure 61: Flue Outlet Positions for Solid Fuel Appliances.