890564_c•en•01.08.2013
We reserve the right to carry out improvements
40
Wisotronic 2/3/4-channel
Installation instructions
6.3.3 Control panel
The control panel can be mounted separately from the location of the power
unit. It simply needs to be connected with a 4-wire line.
JY(St)Y 2 x 2 x 0.8 mm
RD
BK
YE
WH
Wisotronic
power unit
1
1 2 3 4 5 6 7 8 9
Fig. 20
Control panel connection
Control panel: plug-in spring terminals
Permissible conductor diameter
0.6 to 0.8 mm ∅
Stripping length
5 to 6 mm
Power unit: terminal block X5, terminals 1 to 4
Permissible line cross section
0.2 to 2.5 mm
2
single-wire
Stripping length
6.5 mm
Maximum line length
200 m
Only use lines of type JY(St)Y 2x2x0.8 mm.
NOTE
Connections A and B must not be swapped.
Connection