Miscellaneous: Carrier
T7M7G6M,000069A -19-27APR21-1/1
Using Booster Batteries—TR100 System
CAUTION: Avoid possible injury. Always
make sure carrier machine is properly parked
before boost starting.
Before boost starting, machine must be properly parked
with harvester head on ground to prevent unexpected
machine movement when engine starts.
CAUTION: An explosive gas is produced while
batteries are in use or being charged. Keep flames
or sparks away from the battery area. Make sure
the batteries are charged in a well ventilated area.
IMPORTANT: Avoid controller damage. Always
disconnect relay connection box connectors
before using booster batteries. Severe
controller damage will occur requiring
controller replacement.
NOTE: Using booster batteries above 140 amp, requires
controllers to be disconnected. Controller damage
will occur requiring controller replacement.
1. Turn carrier main switch and TR100 key switch control
to OFF position .
2. Remove in-line fuse (F1).
3. Disconnect (XJ9 and XP9, XJ10 and XP10, and XJ11
and XP11) connectors.
4. Connect one end of the positive cable to the positive
terminal of the machine batteries (A) and the other end
to the positive terminal of the booster batteries (B).
5. Connect one end of the negative cable to the negative
terminal of the booster batteries. Connect the other
end of the negative cable to the machine frame as far
away from the machine batteries as possible.
6. Start engine.
7. Allow several minutes before you disconnect the end
of the negative cable from the machine frame. Then
disconnect the other end of the negative cable from
the negative terminal of the booster batteries.
8. Disconnect positive cable from booster batteries and
machine batteries.
TX109781
1A
—UN—14SEP1
1
TR100 relay connection box
T7233JN
—UN—21MA
Y90
A—Machine batteries
B—Booster batteries
A1— Base controller
A10— Relay connection box
XP9— XJ9 and XP9 cab
controller (A2) harness
connector
XP10— XJ10 and XP10 base
controller (A1) harness
connector
XP11— XJ11 and XP11
harvester head
controller (A3) harness
connector
9. Connect (XJ9 and XP9, XJ10 and XP10, and XJ11
and XP11) connectors.
10. Install in-line fuse.