Connection pieces must be tested to DIN EN 1856-2.
Measurement
X
(distance from flammable construction and other materials) must be
as defined by the manufacturer of the connection piece.
PLEASE NOTE:
Fitting to a chimney with a functional height of less than 4 m, or
if several stoves are being fitted, less than 5 m, is not permitted.
(See: Data for chimney calculations / Chapter 4.) A maximum of
two other fires can be connected to the chimney to be connected
to the stove.
For safety reasons it is not permitted to use a steam extractor
hood to remove air when the stove is producing heat.
1.8 Choice of flue gas connection placement
The flue socket is fixed and located at the rear of the range. If the flue pipe is to be
connected on the top, the back wall connection must be covered with the blind cover
removed from the top or the side.
In the case of a connection from the top, the cover in the top of the range must be removed
and the emission nozzle must be installed.