30
1.5 Air supply
A constant supply of oxygen or air is required for the combustion process. Normally the air
available in the room where the stove is installed will be sufficient.
NOTE:
In the room where the stove is installed or in the neighbouring rooms there
must not be any air extractors or similar equipment. These could cause
considerable operating problems and even represent a risk. Consult the local
authority responsible for approving heating systems.
NOTE:
The room where the stove is to be installed must not have equipment such as
extractor hoods, ventilation systems etc. which could mean that that room or
neighbouring rooms have reduced air pressure.
1.6 Safe distances
Ensure that the walls at the sides and behind the range are not constructed of flammable
material and/or clad or coated in flammable material, if they are less than
40 cm
of the side from the combustion chamber, and
30 cm
of the side from the oven.
Plastic or wooden furniture or similar must also be kept at a distance of more than
30 cm
from the back of the range.
No flammable or heat sensitive material should be within
50 cm
of the front of the range in
its field of radiation.
If there is a floor covering or a floor in front of the fire door opening which is flammable or
otherwise sensitive to heat then it should be covered with a layer on non-sensitive or
flammable building material. The layer must cover an area of
50 cm
from the front of the
fire door opening and also a minimum of
30 cm
either side of it. Wall mounted cupboards
over the range must have a minimum clearance of
70 cm
from the hob plate of the range.
1.7 Chimney attachment
The connection for attaching to the chimney must be able to withstand at least 400°C.
PLEASE NOTE:
Before connecting the stove the local authority responsible for approving heating
systems must be consulted!
Connection pieces must be firmly connected to the stove and to each other and must not
leak. They must not project into the open diameter of the chimney. The connection piece
between the stove and the chimney must have the same diameter as the pipe socket on
the stove. Horizontal connection pieces of over 0.5 m must rise towards the chimney at an
angle of 10 degrees. Any pipes which are not heat insulated or vertical must not be longer
than 1 metre.
The requirements of the Fire Regulations (FeuVO) apply, as well as local building
regulations such as for the chimney standards DIN 4705, DIN 18896, DIN 18160,
EN 13384 and EN 15287.
Содержание K 138 JH
Страница 6: ...6 1 2 Ger teaufbau 1 13 9 3 4 2 10 11 12 14 15 6 17 5 7 8 16...
Страница 19: ...19 Bild 6 Bild 7 Bild 9 Bild 11 Bild 11a Bild 12 Bild 13 Bild 14 Bild 10...
Страница 22: ...22...
Страница 23: ...23...
Страница 28: ...28 1 2 Parts 1 13 9 3 4 2 10 11 12 14 15 6 17 5 7 8 16...
Страница 39: ...39 Pic 6 Pic 7 3 6 Pictures Pic 9 Pic 11 Pic 11a Pic 12 Pic 13 Pic 14 Pic 10...
Страница 46: ...46 1 A t zhely elhelyez se 1 1 A t zhely fel p t se 1 13 9 3 4 2 10 11 12 14 15 6 17 5 7 8 16...
Страница 56: ...56 6 bra 7 bra 3 6 br k 9 bra 11 bra 11a bra 12 bra 13 bra 14 bra 10 bra...