Waltron User Manual 101-054-A.1 

9072 Hydrazine Analyzer 

 

WALTRON CUSTOMER COMMITMENT 

This instruction manual is a technical guide to aid the customer in the set-up, operation, 
and maintenance of their new Waltron measuring system.  Waltron provides continuous 
product improvement and reserves the right to make any modifications to the information 
contained herein without notice. 
 

Copyright © Waltron Bull & Roberts, LLC, 2019 

All Rights Reserved 

 
Technical questions concerning this product should be addressed to: 
 

Waltron Technical Service Department 

Flemington, New Jersey 

Phone:

 (908)-534-5100 

Fax:

 (908)-534-5546 

www.waltron.net

 

 
Please be ready to provide the following information: 
 

 

Date analyzer was purchased 

 

Analyzer model and serial number 

 

Recent maintenance history 

 

Calibration slope values and detailed description of problem 

 
 
Waltron’s technical expertise and extensive experience provides personalized solutions to 
the water quality industry.  It is Waltron’s commitment to provide the customer with 
timely and accurate technical service and support. 
 
Waltron fully expects the customer to be satisfied with the quality, performance, and cost 
of this product.   
 
If there are any questions or concerns regarding this product, please feel free to contact 
Waltron at (908)-534-5100. 
 

Thank you for choosing Waltron! 

 
 
Please note the Waltron mailing and shipping address: 
 
 
 

Waltron Bull & Roberts, LLC 

 

25 Minneakoning Road, Suite 101 

 

Flemington, NJ 08822 

 

 

 

 
 

 

 

 

Содержание 9072

Страница 1: ...101 054 A 1 EXPERTS IN WATER CHEMISTRY SINCE 1903 9072 Hydrazine Analyzer User Manual...

Страница 2: ...n net Please be ready to provide the following information Date analyzer was purchased Analyzer model and serial number Recent maintenance history Calibration slope values and detailed description of...

Страница 3: ...ontainers packages and chemicals Only qualified personnel should be involved in the installation operation and servicing of the analyzer Follow safety precautions when operating analyzer in conditions...

Страница 4: ...ce Department Customer name address and department Name and telephone number of the individual responsible for returning items for repair Brief problem description Ship to Waltron service center Waltr...

Страница 5: ...ping needs Check all items received against those on the packing list Chemicals are usually shipped in a separate package and will be itemized accordingly Verify that the number of packages received a...

Страница 6: ...ED PARTS 10 2 2 ACCESSORIES 14 2 3 TERMINAL SCHEMATIC 14 2 4 TECHNICAL DATA 15 3 OPERATING PROCEDURES 16 3 1 PRINCIPLES OF MEASREMENT 16 4 START UP 16 4 1 MENU STRUCTURE 16 4 2 PREPARING TO MEASURE 18...

Страница 7: ...reduce the dissolved oxygen concentrations to protect iron containing metallurgy Hydrazine concentration needs to be continuously monitored to provide feedback to the chemical injection systems and t...

Страница 8: ...is the analytical component which is composed of the inlet valve filter device and flow meter which serve the sample and probe preparation The measuring cell is joined with the temperature sensor and...

Страница 9: ...8 Waltron User Manual 101 054 A 1 9072 Hydrazine Analyzer INTRODUCTION 1 3 THE MEASURING SYSTEM...

Страница 10: ...9 Waltron User Manual 101 054 A 1 9072 Hydrazine Analyzer INTRODUCTION 1 4 BLOCK DIAGRAM OF SENSOR SYSTEM...

Страница 11: ...anual 101 054 A 1 9072 Hydrazine Analyzer INSTALLATION 2 INSTALLATION 2 1 DELIVERED PARTS Arrangement of the wall mounted instrument M measuring electrode C counter electrode R reference electrode T t...

Страница 12: ...11 Waltron User Manual 101 054 A 1 9072 Hydrazine Analyzer INSTALLATION TRANSMITTER MOUNTING...

Страница 13: ...12 Waltron User Manual 101 054 A 1 9072 Hydrazine Analyzer INSTALLATION WET SECTION MOUNTING...

Страница 14: ...8 9 Line 100 230 V 50 60 Hz Line 100 230 V 50 60 Hz Ground earth Limit alarm off Limit alarm on Limit alarm common Alarm on Alarm off Alarm common Auto changing range 2 Auto changing range 1 Auto chan...

Страница 15: ...ime buffer 21 000 data points time set 1 s to 5 min Limit power relay Alarming power relay Flow and Calibration Measuring electrode gold Counter electrode stainless steel 1 4571 314 Reference Electrod...

Страница 16: ...ith that of the reference electrode Under these conditions the rate of the electrochemical reaction is limited by the rate of diffusion of hydrazine molecules to the electrode As long as we remain wit...

Страница 17: ...12 00 SET Menu 03 11 RangeModus 1 2 AutoCal 2 3 AutoCal Period 1 3 RangeModus ManRange SET Period daily RangeModus 2 2 AutoCal Period 2 3 AutoRange SET weekly Menu 04 11 I Output AutoCal Period 3 3 I...

Страница 18: ...Interval 2 5 30 sec SET Logging Interval 3 5 1 min SET Logging Interval 4 5 2 min SET Logging Interval 5 5 5 min SET Logging 3 4 Logging Control Control Press to stop logging Logging Control press to...

Страница 19: ...to the inlet valve The outlet line is placed at the measuring cell exit with a hose having a 5 mm inside diameter 4 3 CHOICE OF OPERATING PARAMETERS Before starting measurement set your operating par...

Страница 20: ...ut current 0 4 20 mA 5th Menu level Limit allows limit settings There exists a switch hysteresis of 10 of the chosen limit 6th Menu level FlowCal enables flow meter calibration see Section 7 7th Menu...

Страница 21: ...verify that all air bubbles in the tube system rinse out To help the bubbles to rinse out open and close quickly the inlet valve several times Attention Make sure that the plugs stay dry 5 2 ANALYZER...

Страница 22: ...ml solution A to 1000 ml deionized water 150 g l N2H4 Calibration solution Add 16 7 ml of solution B to 5 l hydrazine free water 500 g l N2H4 You start the calibration procedure by pressing key and i...

Страница 23: ...de with your fingers thereafter Occasionally a wiping of the electrode surface with a clean tissue is sufficient Thereby you reduce the later start up time until steady state condition 6 2 CLEANING OF...

Страница 24: ...ecting the flow 4 The amount in ml of sample collected in the cylinder during the 60 seconds should be entered digit by digit with the keys and If the value is correct press key SET Press key ESC to g...

Страница 25: ...0 009 1 Measuring electrode Pt H2 L1000 010 1 Salting cell TA L1000 011 1 Salting cell TI L1000 012 1 Sieve L1000 013 1 Set of O rings TI L1000 014 1 Flow meter TA L1000 015 1 Flow meter TI L1000 016...

Отзывы: