Once  you  perform   the  three  bell  operations   after   applying  power

the  bell  will  shut  off

automatically and  you will  hear 

"

Enter  Programming

and the  

Headlight 

and  Reverse Lights will

flash alternately off and on.

Scrolling through the Program 

Options

After entering programming

you will hear an announcement of the first Program 

Option, 

"

Option 

1 - System Volume

".

To access other Program Options, simply flip the direction switch to the opposite 
position and leave it there. Listen as each option number is announced in order

.

Flip the switch back and leave 

it 

there when you wish to stop at a particular option. After 

you stop at an option you will hear the option number and name announced

When you 

are scrolling through and stopping  at Program Options

you are not making any 

changes. 

To make changes you must actually 

enter 

the Program 

Option

.

Note: 

If you accidentally go to a higher option number other than 

the 

one 

you 

wanted, simply turn

the power off

re-enter programming and start again. 

Once 

you reach the last 

Program Option

it

will continue to announce the last option number.

Entering 

a Program Option and Making Changes

After the verbal announcement of a Program  

Option

you can enter that option by performing a

Slow 

or 

Quick 

flip-and-back  operation  of  the  direction  switch

Upon  entering  a  Program 

Option

,

you   will  hear  the  current   setting  for   that   option.  For  unused  Program   Options,   you  will  hear

"Reserved".  

For any volume option

,  

you will hear  

"Volume  

equals X" {where  

"X"  

is its current

volume level setting). After a moment, you will hear the sound playing at its current volume

16

.

Note:  

Entering a Program Option does not change the settings for that option

;  

it only provides

information  about its  current value. After entering the 

Program 

Option,  additional 

Slow 

or 

Quick

flip and-back operations will program new settings as described in the above table. For all level

adjustments

Quick 

operation will decrease one level while a 

Slow 

operation will increase one

level.

Note: 

Since 

"System 

Volume

is the first 

Program 

Option

you can use 

Quick 

or 

Slow 

operations

immediately after entering programming to change the system volume.

Moving on to Other Program Options or Leaving Programming

Flip the direction switch at any time to the opposite position, and leave it there.

Quantum will first return to and announce the current program option and then

automatically advance to onto higher options.

Exit 

Programming 

any time 

you 

want by turning the power off and back on again.

Example 1: Setting Throttle Mode (Program Option# 10)

This will 

determine 

whether 

your locomotive 

uses Regulated Throttle 

Control 

(RTC) or Standard

Throttle 

Control 

(STC)

.

Enter 

Programming 

after powering up your 

engine 

by turning the bell on

then off and 

then on as described above.

After 

the 

"Enter 

Programming"  followed by 

"Option 

One 

System 

Volume" 

announcement of 

the 

first Program 

Option

flip the direction switch and leave it 

there. 

You will hear 

the announcement 

"Option 

1, 

2, 3 

..

etc

.

". 

Stop 

when you hear 

"ten" 

by 

moving 

the 

direction switch back. 

You 

will hear 

"Throttle 

Mode".

Use 

Slow 

or 

Quick 

operation of the direction switch to enter 

this option. 

If 

the 

throttle

mode 

is 

at 

its default value 

(RTC), you will 

hear 

"

Mode 

equals 

Regulated;" 

otherwise,

you will hear 

"

Mode 

equals Standard.

"

Use 

Slow 

or 

Quick 

operation 

of 

the 

direction switch 

to 

change 

the throttle mode

Repeated 

Slow 

or 

Quick 

operations 

will 

cause 

the 

throttle 

mode 

to alternate between 

its two possible 

values 

(RTC, 

STC, RTC

STC 

... 

etc

.

)

Once you have 

selected 

the 

throttle mode 

you wish 

to use

turn the 

throttle off. 

When 

you then 

power 

up 

again, 

your locomotive  will 

be 

using the throttle 

mode 

you have just 

selected.

Example 2: Setting V-Start (Program Option # 8)

This 

will 

determine 

the  voltage 

(and 

throttle 

position) 

where  your 

engine 

will leave  neutral 

and 

move 

out.

Enter 

Programming 

after powering 

up your 

engine 

by turning the bell 

on, 

then off 

and 

then 

on as described above.

After 

the 

"Enter 

Programming"  followed by 

"Option 

One 

System 

Volume" 

announcement 

of 

the first 

Program 

Option, 

flip 

the direction 

switch and 

leave 

it 

there. 

You hear the 

announcement 

"Option 

1

2, 3 

... 

etc

.". 

Stop 

when you 

h

ear  "eight" 

by 

moving the direction 

switch back. 

You will hear 

"

V

-

Start"

.

Use 

Slow 

or 

Quick 

operation 

of 

the 

direction 

switch 

to 

enter 

this 

option. 

You 

will 

hear 

"V-Start 

equals 

X" where 

"

X" 

is the track voltage value 

currently set to 

leave 

neutral

".

"Setting 

any 

volume in Analog will also 

apply 

t

oDCCand 

vice-versa.

Содержание Proto 2000 Series

Страница 1: ...From Walthers RS27 Diesel with QSI Quantum System Sound Train Control Operations Manual...

Страница 2: ...witch to turn it off or if you interrupt the track power If you do a Slow flip and back operation you will get a short horn hoot instead of the bell If you try to do a very short horn blast using a Qu...

Страница 3: ...nds appropriate to its resting state Enter neutral by turning the throttle down below V Start but not off and wait tor the locomotive to stop 7 The Headlight or Mars light switches to a steady dim and...

Страница 4: ...ngine under STC would quickly slow down or stop if it encountered a grade The type of throttle control also affects how your engine decelerates Under STC your engine will respond quickly to a reductio...

Страница 5: ...acing backwards at the end of a consist the Reverse Light faces forwards and will be lit when the consist is moving Forward and there will be no Reverse Light for the consist The Direction program fea...

Страница 6: ...omizes Bell Volume 16 levels Max is 15 15 Motor Volume Volume equals X Customizes diesel Motor Volume 16 levels Max is 15 16 Vents and Cooling Fan Volume Volume equals X Customizes Vents and Cooling F...

Страница 7: ...hange the system volume Moving on to Other Program Options or Leaving Programming Flip the direction switch at any time to the opposite position and leave it there Quantum will first return to and ann...

Страница 8: ...r more information download the Quantum Analog Reference Manual Version 3 from http www walthers com DCC Operation These steps will allow you to start operating your diesel locomotive immediately usin...

Страница 9: ...l Shut Down in Neutral from function F7 instead of function F9 on your DCC command station In Forward and Reverse F7 will still control the locomotive Air Brakes Directional Lighting Operation F0 or F...

Страница 10: ...reduced from high speed travel over 40 smph to less than 20 smph Pressing the F7 key when the engine is moving at any speed will manually activate Squealing Brake sounds and repeated pressings while t...

Страница 11: ...p and down in proportion to the throttle setting Note You can also turn on the Dynamic Brakes see description of Dynamic Brakes below to create Sound of Power as the throttle is moved up and down Engi...

Страница 12: ...le and the engine will enter normal operation Start Up from Total Shut Down If you double press the F6 key in Total Shut Down the diesel locomotive will produce a long air let off you will hear the en...

Страница 13: ...Page 32 Dynamic Brakes on prototype locomotives are lesseffective and are seldom used at lowspeeds...

Страница 14: ...in Service or Ops Mode do the following Set CV 49 to 1 Enter the Mute Volume in CV 51 The System Volume can be set to any value between 0 no sound and 63 100 The default Mute Volume is 63 Note When yo...

Страница 15: ...allow operation with your new Extended Address Disable Enable Verbal Announcements CV 62 In Ops mode Quantum will automatically speak out the value of the CV you enter To disable set CV 62 to 040 to...

Страница 16: ...ng fans shut down you will hear the louvers close Air Pumps When an engine is sitting still the pumps come on in a steady beat to replace the air lost from the brake air release or any other air opera...

Страница 17: ...g Remote Control Muses special signals under Analogcontrol to operate different Quantum features With OARC youcanoperate features thatarecurrently available only in DCC inaddition tofeatures that are...

Страница 18: ...uickly and repeatedly as necessary DCC and QARC only Special Operation and Troubleshooting For a full description see the Troubleshooting section in the Quantum DCC Reference Manual Version 3 at www w...

Страница 19: ...rack voltage exceeds 21 5 volts peak the motor drive circuit will automatically shut down and the engine will coast to a stop while the Quantum System alerts you to the problem through a continuous se...

Страница 20: ...Index 51 Sound Control 0 0 System Volume 0 1 Mute Volume 0 2 Doppler Enabled 52 Individual Sound Volume Control 53 Function Output Mapping 56 OSI Configuration 56 128 n Reset 56 253 Version Build Inf...

Страница 21: ...1 CV 18 Hex 3C CV 17 Binary 11000001 CV 18 Binary 00111100 317 193 61 C1 30 11000001 00111101 415 193 159 C1 9F 11000001 10011111 1416 193 160 C1 AO 11000001 10100000 677 194 165 C2 AS 11000010 101001...

Страница 22: ...tware Firmwareare the valuable properties of OSIndustries Inc Youwillnot make or havemade orpermit tobemade anycopies of theHardware Software Firmware code or any portions thereof Youarenot tomodify a...

Отзывы: