Page
Reset all
37
CV's to Factory Default Values (CV 56.128.255)
Note:
This
does
not affect
Analog
settings, except volumes.
•
Set CV 49 to 128.
•
Set CV 50 to 255
.
•
Set CV 56 to 113
38
•
InOps mode, you will hear 3 hoots when reset is completed.
Special ID Programming (CV 56.129)
If you cannot program your ID number in Service Mode and your command station prevents you
from changing your ID in Ops Mode using CV 1, or CV 17 and CV 18, use the following alternative
procedures to program your engine IDs.
Procedure for Entering Short (Primary) Address
in
CV 56.129 in Ops Mode
•
Set
CV
49 to 129.
•
Set CV 50 to 1
.
•
Set CV 56 to your short address (1 or 2 digits). Hear the address spoken back.
•
If
necessary, set CV 29, bit 5 to
'O' (or
set CV 29 to 6 which is factory default) to
enable your new primary address
.
Procedure for Entering Long
(Extended)
Address in
CV
56.129 in Ops Mode.
•
Determine the value of CV 17 and CV 18 for your Extended
Address
from the ID Table
in your
Diesel Model Specification Sheet
or follow instructions in CV 17 and CV 18 in
the
Quantum DCC Reference Manual (Version 3)
to calculate a different ID number.
•
Set CV 49 to 129.
•
Set CV 50 to 17.
•
Set CV 56 to the value of CV 17 from the table
.
There will be no verbal response
.
•
Set CV 50 to 18.
•
Set CV 56 to the value of CV 18 from the table. Hear the new full Extended Address
spoken out.
•
Set CV 29, bit 5 to
'
1
'
(or set CV 29 to 38
39
)
to allow operation with your new
Extended Address
.
Disable/Enable Verbal Announcements (CV 62)
In
Ops
mode, Quantum
will
automatically speak out the
value
of the CV you enter.
•
To disable set CV 62 to 0
40
;
to enable set CV 62 to 1. Default is Enabled.
CV Inquiry with Verbal Feedback in Ops Mode (CV 64)
41
To inquire about the current value of any CV through Verbal Feedback in Ops Mode:
•
Set CV 64 to the CV you wish to query
.
Hear the verbal message
"
CV
'X'
equals
'
Y
"',
where
'
X
'
is the CV number and
'
Y
'
is the value.
Note:
If the CV has a Primary Index such as OSI CV nn
.
mm (where nn is the
CV
number and mm
is the Primary Index), set CV 49
to
mm before
you
set CV 64 to nn. For example,
if
you want to
inquire about the Bell
Volume
,
which is CV 52.8, set CV 49 to 8 and set CV 64
to
52.
You
will
hear,
"CV
five two point eight equals
'
Y
'
(where 'Y
'
is the current volume setting).
Note:
If you enter either
'17'
or
'
18
'
in
CV 64, you will hear the full Extended
Address ID
number
spoken out.
Common NMRA Configuration Values (CV 29)
Each bit in CV 29 controls some basic operational settings
for DCC
decoders, including Extended
Addressing
,
Speed
Table
Enable
,
Power
Source Conversion,
Lighting
Operation, Locomotive
Direction
,
and others
.
Default is
6
.
"Consult
the
Quantum DCC Reference
Manual
(Version
3)
toleam how to
reset
different groups
of CV's.
38
"
113
"
is
QSl's Manufacturer's IDNumber assigned by the
N
MRA
.
"
En
t
ering"38"
leaves
the
other configuration
settings in
CV 29a
t
factory default
,
but
changes
the ID
to extended
type
.
'°
You will not hear
"
C
V
62
=
o
•
.
"
This option is not affected byCV 62(Disable/Enable
Verbal
Announcements).