background image

Individual Sound Volume Default Settings:

Primary Index entered 

into 

CV 4g

Sound

Default

0

Horn

11

8

Bel

l

11

10

Diesel Motor

10

14

Tu

r

bo

N

/

A

16

Air Pump

11

19

Vents and Coolina Fans

9

21

Lona Air 

Let-off

11

22

Short Air 

Let-off

11

24

Flanges

/

Squealing

Brakes

11

28

Dynamic Brakes

8

34

Coupler Sounds

11

37

Air Brake Sounds

11

The above volume default settings 

apply to both 

Analog 

and 

DCC volume 

settings.

CV 

Factory Default 

Settings

CV 1 Primary 

Address 

(3), 

CV 2 

V-Start 

(32),CV 

5 V-High 

(0).

Magnetic 

Wand Operation:

Your  diesel 

locomotive 

has 

a   special  reed  relay  located  under  the  roof   that  can  be

activated  by a  

Magnetic Wand  

that  

was  

included  

with your  

engine.  

With  

the Magnetic

Wand and without 

touching your 

diesel locomotive, you can:

1)

Increase 

or decrease the system volume

.

2)

Reset 

you locomotive to factory default values.

3) Turn off your locomotive without the need for block control.

4) Turn on your locomotive.

Operations 

with a Magnetic 

Wand 

are described in the 

Special Operation and Trouble

Shooting 

section of your 

Diesel Locomotive Operation Manual.

The diagram

 

    below

 

    shows

 

    the

      location

 

    of

      the

      reed

 

    switch

 

    on

      

the

   

 

  diesel

 

    roof

 

 

.

OSlndustries

,

Inc. Software License Agreement

1.

Grant of License: QSlndustries

,

Inc

.

grants you

,

theowner

,

the righttouse

the 

software that isincluded with your Quantum system only withthelocomotive  thatyoupurchased

.

2.

Copyright: The

software 

isownedbyQSlndustries, Inc

.

andisprotected by United States copyright laws andinternational treaty provisions

.

Therefore, neither younor anyone  else

may 

copy 

the software.

Proprietary Rights 

and 

Obligations

The 

structure 

andorganization 

of 

the 

Software/Firmware

are the valuable properties of OSIndustries

,

Inc. 

Youwillnot make or havemade

,

orpermit tobemade

,

anycopies of

theHardware, Software/Firmware

,

code

,

or 

any 

portions thereof

.

Youarenot tomodify, adapt, translate

,

reverse engineer

,

de-compile, disassemble or 

create

derivative works based

onthe

Hardware 

or Software/Firmware.

Trademarks 

shall

be  usedinaccordance  withaccepted 

trademark 

practice

,

including 

identification

of  trademark  owner's  name

The

QuantumHardware, Software andFirmware are

covered 

by

U

.

S

.

Patent No. 4,914

,

431

;

5

,

184

,

048

;

5,267,318; 5,394,068; 5,448,142; 5,633,985; 5,832,431; 

5

,

896

,

017

5,940,005;

and

USandForeign patents pending

.

No Other R

i

ght

s

OS

Industries,  Inc

.

retainsownership  

of 

the Quantum Hardware  design  

and

operating  Software/Firmwarecode. Except as  

stated above, 

this

agreement 

doesnot  grant  youany

rights to

intellectual 

property rights tothe Quantum 

Software, 

Firmware  or

Hardware. 

Theuse 

of any 

trademarks 

as

herein 

authorized 

does not give youanyrights 

of 

ownership

inthat 

trademark.

©

2005  Allrights reserved.  Printed  inChina. Information in  

thispublication 

supersedes 

that in  

allprevious  pub

l

ishedmaterial.  The 

contents 

and theproduct  

it  

describes  are

subject 

to change without notice

.

OSI is 

a

registered trademark of QSlndustries

,

Inc

.

Quantum, Quantum System, 

Sound-of-Power, Scale Sound,

Regulated Throttle Control

,

QARC, are trademarks of QS

l

ndustries

,

Inc.

MRC is atrademark of 

Model 

Rectifier Corporation. 

All 

other trademarks are the 

property of their respective holders. OSImakes norepresentationsor warranties withrespect 

to 

this publication

.

Inno event 

shall 

QS

l

ndustries

,

Inc., be 

liable 

for any damages

,

direct 

or 

incidental, arising out 

of or 

re

l

ated

to the use 

of 

this publication.  8/04 

QSlndustries

,

Inc

Beaverton

,

OR

Page 

20

WALTHERS

@2005 

Wm

K

Walthers

Inc.

5601 

W. 

Florist 

Avenue 

Milwaukee

WI 

53218

RM585280

Содержание Proto 2000 Series

Страница 1: ...From Walthers RS27 Diesel with QSI Quantum System Sound Train Control Operations Manual...

Страница 2: ...witch to turn it off or if you interrupt the track power If you do a Slow flip and back operation you will get a short horn hoot instead of the bell If you try to do a very short horn blast using a Qu...

Страница 3: ...nds appropriate to its resting state Enter neutral by turning the throttle down below V Start but not off and wait tor the locomotive to stop 7 The Headlight or Mars light switches to a steady dim and...

Страница 4: ...ngine under STC would quickly slow down or stop if it encountered a grade The type of throttle control also affects how your engine decelerates Under STC your engine will respond quickly to a reductio...

Страница 5: ...acing backwards at the end of a consist the Reverse Light faces forwards and will be lit when the consist is moving Forward and there will be no Reverse Light for the consist The Direction program fea...

Страница 6: ...omizes Bell Volume 16 levels Max is 15 15 Motor Volume Volume equals X Customizes diesel Motor Volume 16 levels Max is 15 16 Vents and Cooling Fan Volume Volume equals X Customizes Vents and Cooling F...

Страница 7: ...hange the system volume Moving on to Other Program Options or Leaving Programming Flip the direction switch at any time to the opposite position and leave it there Quantum will first return to and ann...

Страница 8: ...r more information download the Quantum Analog Reference Manual Version 3 from http www walthers com DCC Operation These steps will allow you to start operating your diesel locomotive immediately usin...

Страница 9: ...l Shut Down in Neutral from function F7 instead of function F9 on your DCC command station In Forward and Reverse F7 will still control the locomotive Air Brakes Directional Lighting Operation F0 or F...

Страница 10: ...reduced from high speed travel over 40 smph to less than 20 smph Pressing the F7 key when the engine is moving at any speed will manually activate Squealing Brake sounds and repeated pressings while t...

Страница 11: ...p and down in proportion to the throttle setting Note You can also turn on the Dynamic Brakes see description of Dynamic Brakes below to create Sound of Power as the throttle is moved up and down Engi...

Страница 12: ...le and the engine will enter normal operation Start Up from Total Shut Down If you double press the F6 key in Total Shut Down the diesel locomotive will produce a long air let off you will hear the en...

Страница 13: ...Page 32 Dynamic Brakes on prototype locomotives are lesseffective and are seldom used at lowspeeds...

Страница 14: ...in Service or Ops Mode do the following Set CV 49 to 1 Enter the Mute Volume in CV 51 The System Volume can be set to any value between 0 no sound and 63 100 The default Mute Volume is 63 Note When yo...

Страница 15: ...allow operation with your new Extended Address Disable Enable Verbal Announcements CV 62 In Ops mode Quantum will automatically speak out the value of the CV you enter To disable set CV 62 to 040 to...

Страница 16: ...ng fans shut down you will hear the louvers close Air Pumps When an engine is sitting still the pumps come on in a steady beat to replace the air lost from the brake air release or any other air opera...

Страница 17: ...g Remote Control Muses special signals under Analogcontrol to operate different Quantum features With OARC youcanoperate features thatarecurrently available only in DCC inaddition tofeatures that are...

Страница 18: ...uickly and repeatedly as necessary DCC and QARC only Special Operation and Troubleshooting For a full description see the Troubleshooting section in the Quantum DCC Reference Manual Version 3 at www w...

Страница 19: ...rack voltage exceeds 21 5 volts peak the motor drive circuit will automatically shut down and the engine will coast to a stop while the Quantum System alerts you to the problem through a continuous se...

Страница 20: ...Index 51 Sound Control 0 0 System Volume 0 1 Mute Volume 0 2 Doppler Enabled 52 Individual Sound Volume Control 53 Function Output Mapping 56 OSI Configuration 56 128 n Reset 56 253 Version Build Inf...

Страница 21: ...1 CV 18 Hex 3C CV 17 Binary 11000001 CV 18 Binary 00111100 317 193 61 C1 30 11000001 00111101 415 193 159 C1 9F 11000001 10011111 1416 193 160 C1 AO 11000001 10100000 677 194 165 C2 AS 11000010 101001...

Страница 22: ...tware Firmwareare the valuable properties of OSIndustries Inc Youwillnot make or havemade orpermit tobemade anycopies of theHardware Software Firmware code or any portions thereof Youarenot tomodify a...

Отзывы: