background image

Page 14

Function Key Operation in Neutral

Some 

Function Keys used in Forward 

and 

Reverse 

will 

have 

different effects in 

Neutral:

The F7 key produces 

Brake Squeal 

for a moving engine but produces a long 

air 

let-off 

in neutral.

Pressing F6 

results 

in Doppler 

shift for a moving engine 

but 

activates 

Start Up 

in 

neutral.

Pressing 

F9 produces a short 

Air 

Let-off in a moving engine but activates Shut 

Down 

in 

neutral.

Note:  

Horn

,  

Bell

,  

Doppler  

Shift

,  

Squealing Brake and Neutral sounds are described in detail on

page 

15

in the 

Quantum System Sounds 

section of this manual.

DCC Programming

Most  command   stations  currently   available   will  program  Quantum   equipped  

locomotives 

in

Service or 

Ops Mode

If your command station will not program in Service Mode, check with the

command   station  manufacturer  

some  companies   will  give  you  a   free  upgrade.  Also,   see

Troubleshooting on page 16.

Changing the System Volume Electronically in CV 51.0

You   can   change   the   volume   either   manually   as   described   in   the  

Special   Operation   and

Troubleshooting 

section  or  electronically  using  QSI  CV  51.0  in  DCC

33

• 

To  change   volume  in

Service or 

Ops 

Mode, do the following

:

SetCV49to0.

34

Enter the System 

Volume 

in CV 51

.

The System Volume can be set to any value

between 

(no sound) and 127 (100%). 

The 

default System 

Volume 

is 127

.

Note: 

When you 

change 

the 

System 

Volume

you will immediately notice the change in volume in

Ops 

Mode.

Changing the Mute Volume Electronically in CV 51.1

To change the Mute 

Volume in 

Service or Ops 

Mode

do 

the 

following:

Set CV 49 

to 1

.

Enter the 

Mute 

Volume in CV 51. The System Volume can be set to any value between

0 (no sound) and 63 (100%).  The default 

Mute Volume 

is 63.

Note: 

When  you  change  the  Mute  Volume,  and 

the 

locomotive  is  muted,  you  will  immediately

notice the change in 

Mute Volume 

in Ops Mode.

Note: 

The Mute 

Volume 

level will be the smaller of either the Mute 

Volume 

setting or one half the

current  

System Volume

.  

In  

other words

,  

the  

Mute Volume  

will never be more than one half the

system 

volume

.

Enable/Disable Horn Triggered Doppler Shift (CV 51.2)

Set 

CV 

49 

to 

2

.

Set CV 51 to 

Oto 

disable 

Horn Triggered Doppler

set 

to 

to 

enable 

Horn 

Triggered

Doppler

.

Changing Individual Sound Volumes (CV 52.X 

35

)

To change  the volume of individual sounds listed 

in 

the 

table 

below do 

the 

following

36

:

Set CV 49 

to the Primary 

Index 

for the individual 

sound 

from the table 

below.

Enter 

Volume level in CV 

52 as follows: 

"

0

No 

sound, 

"1 

15

sets 

volume 

from the

lowest level 

at 

"

1

to the highest at 

"

15

"

with volume levels 

at 2db increments.

Primary Index entered into CV 49

Sound

0

Horn

8

Bell

10

Diesel  Motor

16

Air Pump

19

Vents 

and 

Cooling 

Fans

21

Long Air Let-off

22

Short 

Air 

Let-off

24

Flange

s/

Squealing 

Brak

e

s

28

Dynamic 

Brakes

34

Coupler  Sounds

37

Air 

Brake 

Sounds

See your 

Diesel Model Specifications 

sheet for individual sound volume default settings.

33

System Volume 

changes in

DCCalso 

apply 

to Analog 

and 

vi

ce-

versa

.

You will hear the value 

spoken out(Ops 

Mode

Only).

'X' 

refers 

tothe value 

incolum

n

1 of the table

,

thePrimary 

Index 

number that will 

be

entered intoCV 

49

.

36

Setting 

any Individual 

Fea

t

ureVolume 

in 

DCC will 

also apply 

to Analog 

and 

vice-versa.

Содержание Proto 2000 Series

Страница 1: ...From Walthers RS27 Diesel with QSI Quantum System Sound Train Control Operations Manual...

Страница 2: ...witch to turn it off or if you interrupt the track power If you do a Slow flip and back operation you will get a short horn hoot instead of the bell If you try to do a very short horn blast using a Qu...

Страница 3: ...nds appropriate to its resting state Enter neutral by turning the throttle down below V Start but not off and wait tor the locomotive to stop 7 The Headlight or Mars light switches to a steady dim and...

Страница 4: ...ngine under STC would quickly slow down or stop if it encountered a grade The type of throttle control also affects how your engine decelerates Under STC your engine will respond quickly to a reductio...

Страница 5: ...acing backwards at the end of a consist the Reverse Light faces forwards and will be lit when the consist is moving Forward and there will be no Reverse Light for the consist The Direction program fea...

Страница 6: ...omizes Bell Volume 16 levels Max is 15 15 Motor Volume Volume equals X Customizes diesel Motor Volume 16 levels Max is 15 16 Vents and Cooling Fan Volume Volume equals X Customizes Vents and Cooling F...

Страница 7: ...hange the system volume Moving on to Other Program Options or Leaving Programming Flip the direction switch at any time to the opposite position and leave it there Quantum will first return to and ann...

Страница 8: ...r more information download the Quantum Analog Reference Manual Version 3 from http www walthers com DCC Operation These steps will allow you to start operating your diesel locomotive immediately usin...

Страница 9: ...l Shut Down in Neutral from function F7 instead of function F9 on your DCC command station In Forward and Reverse F7 will still control the locomotive Air Brakes Directional Lighting Operation F0 or F...

Страница 10: ...reduced from high speed travel over 40 smph to less than 20 smph Pressing the F7 key when the engine is moving at any speed will manually activate Squealing Brake sounds and repeated pressings while t...

Страница 11: ...p and down in proportion to the throttle setting Note You can also turn on the Dynamic Brakes see description of Dynamic Brakes below to create Sound of Power as the throttle is moved up and down Engi...

Страница 12: ...le and the engine will enter normal operation Start Up from Total Shut Down If you double press the F6 key in Total Shut Down the diesel locomotive will produce a long air let off you will hear the en...

Страница 13: ...Page 32 Dynamic Brakes on prototype locomotives are lesseffective and are seldom used at lowspeeds...

Страница 14: ...in Service or Ops Mode do the following Set CV 49 to 1 Enter the Mute Volume in CV 51 The System Volume can be set to any value between 0 no sound and 63 100 The default Mute Volume is 63 Note When yo...

Страница 15: ...allow operation with your new Extended Address Disable Enable Verbal Announcements CV 62 In Ops mode Quantum will automatically speak out the value of the CV you enter To disable set CV 62 to 040 to...

Страница 16: ...ng fans shut down you will hear the louvers close Air Pumps When an engine is sitting still the pumps come on in a steady beat to replace the air lost from the brake air release or any other air opera...

Страница 17: ...g Remote Control Muses special signals under Analogcontrol to operate different Quantum features With OARC youcanoperate features thatarecurrently available only in DCC inaddition tofeatures that are...

Страница 18: ...uickly and repeatedly as necessary DCC and QARC only Special Operation and Troubleshooting For a full description see the Troubleshooting section in the Quantum DCC Reference Manual Version 3 at www w...

Страница 19: ...rack voltage exceeds 21 5 volts peak the motor drive circuit will automatically shut down and the engine will coast to a stop while the Quantum System alerts you to the problem through a continuous se...

Страница 20: ...Index 51 Sound Control 0 0 System Volume 0 1 Mute Volume 0 2 Doppler Enabled 52 Individual Sound Volume Control 53 Function Output Mapping 56 OSI Configuration 56 128 n Reset 56 253 Version Build Inf...

Страница 21: ...1 CV 18 Hex 3C CV 17 Binary 11000001 CV 18 Binary 00111100 317 193 61 C1 30 11000001 00111101 415 193 159 C1 9F 11000001 10011111 1416 193 160 C1 AO 11000001 10100000 677 194 165 C2 AS 11000010 101001...

Страница 22: ...tware Firmwareare the valuable properties of OSIndustries Inc Youwillnot make or havemade orpermit tobemade anycopies of theHardware Software Firmware code or any portions thereof Youarenot tomodify a...

Отзывы: