8.2 Cleaning
IMPORTANT
Only use soft brushes for outside cleaning of the nozzle tips. Never use metal tools
with sharp edges.
Wash equipment thoroughly after use to remove residues and dirt, especially if needle (9) or adapter nozzle
(1) have to be exchanged. Use the thinner for sprayable media as detergent. A daily cleansing rinse will re-
move residues of the sprayable medium and clean almost all parts and channels which have been in contact
with the sprayable medium. Do not put the complete spray pistol into a thinner-bath as this will also remove
the lubricants.
8.3 Inserting new Gasket Elements
IMPORTANT
Gaskets and gasket holders can be damaged.
Do not use any sharp or pointed metallic implements for inserting the sealings!
8.4 Replacing Nozzle (1), TEFLON-sealing (5) and Needle (9)
Disconnect supply hoses (at M6 IG and 15) from device
Unscrew needle lock (12); extract spring (11)
Unscrew nozzle (1)
Use a soft tool to push back needle (9) through the needle sealing
Unscrew sealing screw (11) with slot screwdriver
You can easily exchange all elements now
Sequence for assembling:
Screw in sealing screw (11)
Screw in nozzle (1)
Insert needle (9) into the body through the sealing screw
Screw in needle lock (12)
8.5 Spare Parts
IMPORTANT
Only use original spare parts from the manufacturer!
Wrong or defective spare parts from other manufacturers can damage the device. If
other than original spare parts of the manufacturer will be used, all obligations from the
manufacturer or his sales partners, such as guarantees, service contracts etc will be
forfeited
without further notice.