Maintenance
19
DOK BEMO 11/20 Rev.01 PM
9 Maintenance
This chapter is intended for wallbox operators.
WARNING
Death or risk of injury from electric shock due to contact with live components
f
Observe the five safety rules defined according to DIN VDE 0105-100.
f
Ensure that the supply voltage is switched off.
f
Ensure that power supply cable is electrically dead.
Der Betreiber muss die Wallboxen in regelmäßigen Abständen durch eine Elektrofachkraft mit
nachweislichen Kenntnissen auf ordnungsgemäßen Zustand prüfen lassen.
The manufacturer recommends that the regular maintenance intervals should be adapted to the operating
conditions and installation site.
f
Check wallboxes and connection cables for damage before each use.
f
Maintenance must be carried out regularly by a qualified electrician according to the protocols of the
standard DIN VDE 0100-600 and in accordance with country-specific requirements and guidelines.
f
DGUV regulation 3 inspection should be carried out annually, ideally quarterly.
f
Press the test button on the MCB/RCD combination (RCBO) at least once a month.
f
Individually test the active conductors for the trigger time and trigger current, and record the results.
f
In case of defective components, contact the manufacturer's service centre.
WARNING
Death or risk of injury from electric shock due to contact with live components
f
Do not open the enclosure during the visual inspection.
f
Never touch inside the sockets.
f
Never insert objects of any kind into the sockets.
A visual inspection can be carried out by non-specialist persons.
f
Check wallboxes for external damage.
f
Check function of the socket covers.
f
In case of damage, contact a qualified electrician. Stop using the use wallboxes and mark them
as defective.