5.c.1. Restriction of space around the stove
The figure below (fig. 5.c.1.) shows the minimum distances to flammable
materials and other items which have to be kept when installing the stove.
a)
adjoining wall
b)
back wall
c)
side wall
d)
floor protection
Every item which is eventually flammable has to be protected from the heat. Floors made
of wood or other flammable materials have to be covered with heat-resistant materials
as, for instance, a metal plate of 2-3 mm. The metal plate has to cover the complete part
of the floor in front of the stove.
! Please control the norms valid in the installation country.
5.c.2. Restriction of space above the stove
If there are any beams above the stove and the
chimney hood, they have to be insulated with
heat-resistant material (fig. 5.c.2.).
a)
front floor protection 30 – 50 cm
b)
side adjoining wall 20 cm
c)
upper wall and chimney hood 50 cm
Attention: Leave enough space for eventual maintenance work.