background image

 

Revision 15 

 

 

 

1. Disclaimer & Copyright Notice 

 

Every effort has been made to supply information within this manual which is correct.  
Wallgate Limited will not be liable for any damage or loss that arises if the person 
installing, operating or maintaining the unit has not read or not complied with the 
manual  

 
In any event, and without prejudice to any warranties in Wallgate Limited’s terms and 
conditions of sale, Wallgate Limited’s liability for all damages and losses (including 
negligence) shall not in any circumstances exceed the amount paid by the customer 
for the unit.   
 
Wallgate reserves the right to alter, update or improve its product specification at any 
time without prior notice. This manual is specific to the product that it has been 
supplied with at the date of supply.  
 
Without prejudice to any warranties in Wallgate Limited’s terms and conditions of 
sale, any warranty will be invalidated if the equipment is installed or serviced by 
unqualified personnel. 
 
No part of this publication and the information contained may be reproduced, 
transmitted, stored in a retrieval system, used or disclosed wholly or partly without 
prior written permission from Wallgate Limited.   
 
For full warranty details please see Wallgate Limited Terms and Conditions. 
 
Please ensure this manual is passed to the end user. The manual forms an integral 
part of the product and should be kept for its working life. Additional copies of this 
and other supporting documents are available by contacting Wallgate Limited or by 
visiting www.wallgate.com

 

 
 
 
 
 

Содержание WDC100

Страница 1: ...Product Manual WDC100 Electronic Control For Basins Baths Showers and WCs ...

Страница 2: ...Revision 15 2 Product Manual Solid Surface WC Pans Product Manual WDC100 Electronic Control AS 1172 Certificate No 23167 RCM Mark Australia ...

Страница 3: ...ontroller Unit 10 5 4 Connect the Input and Output Cables 11 5 4 1 Connect the 3 pin connector 12 5 4 2 Connect the 3 5 mm connector 12 5 5 Connect the Electrical Supply 13 5 6 Commission the Unit 14 5 6 1 Purge Cycle function 14 5 6 2 Lockout function 15 5 6 3 Piezo touch button and infrared sensor controls 16 5 6 4 System Test function 17 5 6 5 Product Time Slots 18 5 6 6 Hygiene Purge 18 5 6 7 ...

Страница 4: ...me without prior notice This manual is specific to the product that it has been supplied with at the date of supply Without prejudice to any warranties in Wallgate Limited s terms and conditions of sale any warranty will be invalidated if the equipment is installed or serviced by unqualified personnel No part of this publication and the information contained may be reproduced transmitted stored in...

Страница 5: ...e serious consequences WARNING This is a warning 2 2 Note A note with amber text on a white background is used to draw your attention to important and useful information NOTE This is a note 2 3 Numbered procedures Steps in procedures are numbered starting from 1 1 This is step 1 2 This is step 2 etc 2 4 Bullet lists 2 4 Bullet lists A bullet list is used to give information that is not sequential ...

Страница 6: ...dalone networking of the WDC control units to a dedicated PC or laptop computer You can manage the WDC units through the network You can also adjust time cycle settings lockout settings remote water isolation on individual units or groups RTC settings etc You can also view the unit status in real time and log data Data Logging Activations of the Hygiene Purge function detailed below are logged in ...

Страница 7: ...connect the WDC unit to a PC or laptop RTC Real Time Clock This is a 24 hour 7 day clock used by the WDC100 for program features such as Time Slots and Hygiene Purge System Test The System Test is a feature that allows you to operate switches and piezo touch buttons and make sure that these operate the necessary outputs such as lights or valve solenoids Time Slots Usage of services such as basins ...

Страница 8: ...rity controlled access Independent control of multiple outlets Fully programmable precise time control of water valve operation that is fully adjustable in situ by the installer customer LOCKOUT function to prevent product misuse that is fully adjustable for the number of user operations operations period lockout period and the LOCKOUT function can be ENABLED or DISABLED to suit the individual req...

Страница 9: ...it upside down The control box has four feet with holes for attaching the unit to the wall using four round head screws No 8 x 30mm 1 25 inch For the location of the mounting feet refer to Figure 1 on page 10 5 2 2 Electrical connections All cables must be connected to the unit using the sockets at the bottom of the unit enclosure The power cable must be connected to the unit through the cable gla...

Страница 10: ...suitable wall plugs if necessary 4 Attach the unit to the wall using four round head screws NOTE When mounting the unit make sure the cable sockets at the bottom of the unit point downwards Figure 1 WDC100 Lower Panel Item No Description Function 1 Water Valve Cable Sockets Output to WC shower and washbasin or bath water valves 2 Input Device Sockets Input from piezo touch buttons or infrared sens...

Страница 11: ...h button User input Piezo button or IR sensor for Shower C Input from Basin or bath Cold touch button User input Piezo button or IR sensor for Basin bath Cold D Input from Basin or bath Hot touch button User input Piezo button or IR sensor for Basin bath Hot E Auxiliary 1 Auxiliary input set to Remote L O F Auxiliary 2 Auxiliary input set to Remote Flush G Auxiliary 3 Auxiliary input set to Half F...

Страница 12: ...e connector to the socket in the unit carry out these steps 1 The cable plug has a raised key that must be aligned with the slot in the socket for it to fit correctly Push the connector fully into the socket and pull it back out slightly to check the latch on the front of the plug has engaged the socket To remove the plug the press the latch button down firmly with your thumb and pull out the plug...

Страница 13: ...e 2 Connect an earth conductor to the water supply pipes on the basin bath and shower nozzles The other end of the earth conductor must be connected to an approved earth facility NOTE The water pipes connected to the basin bath taps and shower nozzles must be bonded to earth 3 Make sure that the Piezo touch button or infra red sensor leads from the basin bath tap shower and WC are plugged into the...

Страница 14: ...ycle function you can use when commissioning the installation of the basins showers and WC sanitary ware The Purge Cycle function opens the water valves for the basin bath shower and WC pan in an automatic sequence This can help release any air trapped in the plumbing system The Purge Cycle sequence does the following Runs the basin bath hot and cold water for 1 minute Valve sockets Legend Menu Ke...

Страница 15: ... any problems such as blockages before you run the purge cycle again The control unit has various function settings that can be enabled or disabled The settings are given in section 7 WDC100 Menu Settings 5 6 2 Lockout function The Lockout function restricts the number of usages for the basin bath shower and WC The Lockout feature is disabled by default The Lockout function restricts usage to 10 c...

Страница 16: ...trol unit is set for use with Piezo touch buttons by default If you connect infrared sensors to the control unit you must modify the applicable setting For instructions on how to do this refer to Table 5 on page 23 You do not have to modify this setting if the control unit is factory set for operation with infrared sensors The Piezo touch buttons do not have any moving parts To operate the Piezo t...

Страница 17: ...inputs touch buttons or infra red sensors and the outputs water valves This is useful for fault finding if any of the valves fail to operate You can also use this function to make sure that the touch buttons and valves have been connected to the correct sockets on the control unit To start the System Test function 1 Press and hold down the and keys for five seconds The firmware version appears 2 P...

Страница 18: ...d basins can be assigned to a configurable timeslot and when activated the assigned output will only become active if within the allowed time slot This function can be used to manage when sanitary ware is allowed to operate for instance the showers may become inactive during night time periods See Table 5 pages 24 27 for Time Slot setting information 5 6 6 Hygiene Purge The control unit has the ab...

Страница 19: ...h output Refer to section 7 to view the available time settings When an output operates at the set time it is ON for the preset cycle run time as set in Cell Water Settings of the WDC100 menu 5 7 Technical Specifications Table 3 Technical specifications Power supply 115 230V AC Fuse 2Amp 50Hz Single phase UK Europe Australasia Maximum Rating 60 Watts Refer to model WDCA100 for North America Enclos...

Страница 20: ...will cancel the operation The shower and WC cycles however cannot be interrupted in this way Hold your hand within 50mm of the infrared sensor to operate an infra red sensor The operation cannot be interrupted or stopped when infra red sensors are fitted The hot and cold basin bath valves are opened for 10 seconds each The hot warm and cold shower valve is opened for 60 seconds The WC flush valve ...

Страница 21: ...avoid immediate loss of the date and time settings See Table 5 on page 23 for instructions on setting the date and time Time Slots All Default setting is All which does not restrict product usage Refer to Table on page 23 Hygiene Purge Off Refer to Table on page 23 Remote AUX Input set up E Remote Lockout F Remote Flush G Half flush The three Remote inputs can be assigned to operate any of the rem...

Страница 22: ...vice package details of which can be obtained from our customer service department A spare parts service is also available The electronic control unit does not have any user serviceable parts In the event of a fault switch off the electrical supply and contact an authorised electrician to replace the unit Any service or repair work must be carried out by a qualified engineer During the warranty pe...

Страница 23: ...ter Lockouts Water Lockouts Enabled or Disabled Disabled Select the operating mode and defaults Mode Defaults Cell or Communal Cell Enable or disable Cistern Sharing Cistern Sharing Enabled or Disabled Disabled Enable or disable the High Voltage Flush High Volt Flush Enabled or Disabled Disabled Enable or disable Double Press Flush Double Press Flush Enabled or Disabled Disabled Enable or disable ...

Страница 24: ...avel 1 to 100 or OFF 100 This must not be set below the default value of 100 Permitted number of WC activations W C Cycle Activations 1 to 100 Activations 4 Activations Time period of a WC activation cycle W C Cycle Period 15 to 1440 Minutes 15 Minutes WC lockout time W C Lockout Time 15 to 1440 Minutes 15 Minutes WC cistern refill time W C Refill Time 1 to 999 Seconds 30 Seconds Oli Travel The de...

Страница 25: ...06 00 Time Slot 2 Start 00 00 to 23 00 06 00 Time Slot 2 End 00 00 to 23 00 12 00 Time Slot 3 Start 00 00 to 23 00 12 00 Time Slot 3 End 00 00 to 23 00 18 00 Time Slot 4 Start 00 00 to 23 00 18 00 Time Slot 4 End 00 00 to 23 00 00 00 Reset Item Time Slots Select Time Slot All None 2 4 1 3 4 3 2 1 All Specify the timings for 4 W C Time Slots Reset the Time Slots Select All None or a specified numbe...

Страница 26: ...Off or 1 to 100 Days Off Specify the period for purging the basin Basin Purge Time 1 to 999 Seconds 60 Seconds Specify the period for shower inactivity Shower Inactivity Period Off or 1 to 100 Days Off Specify the period for purging the basin Shower Purge Time 1 to 999 Seconds 60 Seconds Specify the period for WC inactivity W C Inactivity Period Off or 1 to 100 Days Off ...

Страница 27: ...07 30 N N N N 08 00 N N N N 08 30 N N N N 09 00 N N N N 09 30 N N N N 10 00 N N N N 10 30 N N N N 11 00 N N N N 11 30 N N N N 12 00 N N N N 12 30 N N N N 13 00 N N N N 13 30 N N N N 14 00 N N N N 14 30 N N N N 15 00 N N N N 15 30 N N N N 16 00 N N N N 16 30 N N N N 17 00 N N N N 17 30 N N N N 18 00 N N N N 18 30 N N N N 19 00 N N N N 19 30 N N N N 20 00 N N N N 20 30 N N N N ...

Страница 28: ...3 00 N N N N 23 30 N N N N 00 00 N N N N 00 30 N N N N 01 00 N N N N 01 30 N N N N 02 00 N N N N 02 30 N N N N 03 00 N N N N 03 30 N N N N 04 00 N N N N 04 30 N N N N 05 00 N N N N 05 30 N N N N The default setting for the auto run function is N OFF on all outlets for all time settings Changing the default to Y will set that outlet to switch ON at that time setting ...

Страница 29: ...ion Product Manual for WDCMS optional software for networking WDC units to a PC or laptop Product Manual for Data Logging optional software for downloading hygiene purge activation logs from the WDC control units and creating log reports ...

Страница 30: ...Revision 15 2 Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...

Отзывы: