background image

 

 

1. INTRODUCTION 

 

Welcome to your handwash unit. The unit has been designed and manufactured from quality 
materials. If these user instructions are followed, the unit will give reliable efficient service. If 
you need further information, please contact Wallgate Ltd. 
 
The two models are follows: 
 

  Push button operation, model CME_41. 

  Automatic infra-red sensor operation, model CME_45. 

 

It is important that you establish which model of unit you have installed so that you are able 
to  follow  these  instructions  correctly.  The  cycle  times  for  the  unit  have  been  set  to  provide 
highly effective hand washing at low cost. 

 

The installer will have passed to you this manual & the key to open the lower drawer panel. 
The upper fascia  panel  is  secured  with  two  security  screws  which  require  a  RESIST-TORX 
T30 key. 

2. OPERATING THE UNIT 

The unit is switched “ON” or “OFF” by the isolation switch behind the top door panel or at the 
mains switch located near the unit on the wall. If a fault occurs with the unit, then it must be 
switched “OFF” until a qualified engineer has repaired the fault. 

WARNING: 

Unqualified personnel must not remove the internal cover, due to the risk of 

electric shock. 

 

For the CME-41 push button operated model follow the instructions below: 

 

  For  soap  dispensing  press  the  hand  or  foot  button  marked  “SOAP”.  Dosage  depends 

entirely  on  the  number  of  times  the  button  is  pressed. The  electric  type  pump  runs for a 
pre-set time 0.3 seconds to deliver approximately 5ml of soap. This can only be adjusted 
by  consulting  the  manufacturer.  The  soap  button  however  can  be  pressed  several  times 
for repeat operations if more soap is required. 
 

  For  water  dispensing  press  the  push  button  marked  “WATER”.  The  time  cycle  has  been 

set  to  12  seconds.  The  setting  can  be  adjusted  as  detailed  on  the  following  page  titled 
“Time Cycle Adjustments”. The water cycle can be repeated by pressing the button again.  
 

  For hand drying, press the hand or foot button marked “AIR. The time cycle will have been 

set  to  35  seconds  and  can  be  adjusted  as  detailed  on  the  following  page  “Time  Cycle 
Adjustments”. The air cycle can be repeated by pressing the button again. 
 

Note:  The  water  &  air  cycles  can  be  interrupted  when  in  operation.  For  example,  when  the 
water  cycle  is  running,  pressing  the  air  button  will  stop  the  water  and  start  the  air  cycle. 
Similarly, pressing the soap button would cancel the water cycle if it were running at the time. 

 
 
 
 
 
 
 

OPERATING & MAINTENANCE INSTRUCTIONS 

FOR MODELS  CME_41 & CME_45. 

Содержание CME 41

Страница 1: ...ts Contact our Customer Services Department Tel 01722 744594 Fax 01722 742096 Sales or 742933 Service Email sales wallgate com service wallgate com Crow Lane Wilton Salisbury Wiltshire SP2 OHB www wallgate com Hand Wash Drier Models CME_41 45 Product Manual CME_45 ...

Страница 2: ...st be installed c Complete all surface finishes i e screed plaster or tiling to the wall before fixing the mounting brackets as these must be fitted flush with the finished surface d An electrical supply should be provided with a switched fused spur 13Amp double pole connection point that is local to the unit the contact separation of the fused spur switch should be at least 3mm A suitable cable w...

Страница 3: ...et sides in too far which will then prevent the satisfactory operation of the drawer in its slides The cabinet sides should be set apart a distance of 541mm 21 5 16 to their outer edges Once all four points are set press the unit fully into the aperture and tighten the four bolts 4 ELECTRICAL CONNECTION WARNING This appliance must be earthed a The CME is designed for a fixed wire type installation...

Страница 4: ...bove the basin The isolator switch should illuminate red f To check that the unit operates and to complete the final set up procedures now refer to the Operating Maintenance Instructions sections 3 2 4 in this order g On completion of the above replace the top fascia panel and lock the lower drawer The following items should be passed to the customer 1 off lower drawer key this Product Manual 7 TE...

Страница 5: ......

Страница 6: ...over due to the risk of electric shock For the CME 41 push button operated model follow the instructions below For soap dispensing press the hand or foot button marked SOAP Dosage depends entirely on the number of times the button is pressed The electric type pump runs for a pre set time 0 3 seconds to deliver approximately 5ml of soap This can only be adjusted by consulting the manufacturer The s...

Страница 7: ...with one of two electronic controllers TCU041 or TCU100 which is mounted towards the top inside face of the handwash housing The TCU041 controller is used on units with just soap water and air functions push button operated The time settings may be adjusted by following the adjacent instructions The TCU100 is fitted to the CME_45 model time cycles may be adjusted using the onboard Control Interfac...

Страница 8: ...will only operate the water heater when the flow rate is set above 1 2ltr min 5 MAINTAINANCE Wallgate operates a comprehensive service package details of which can be obtained from our After Sales Service department A full spare parts facility is also available WARNING The water heater is an open outlet type and under no circumstances should the water outlet nozzle be allowed to become blocked or ...

Отзывы: