background image

Driving eMobility

10/16

Installation Manual

 

3.5   Electrical connection

Figure 6: wallbe® LEO, opened electronics housing

Prerequisites

The Wallbox can be connected with a single phase 1 AC 
230 V or with three phases 3 AC 400 V.

1. Remove the four screws (Fig. 6/1) and take off the 
cover of the electronics housing (Fig. 6/2).

2. Screw the cable gland ESKV25 (enclosed accesso-
ries) with the respective gasket EADR25 (enclosed ac-
cessories) into the electronics housing (Fig. 6/3) and 
tighten (approx. 8 Nm).

3. Strip off maximum 13 cm jacket from the power 
supply cable.

4. Strip off approx. 11 to 13 mm insulation from the 
individual wires.

5. Follow the instructions on the sticker (Fig. 6/4) and 
then pierce the sticker on the cable entry.

6. Insert the connecting line into the cable gland.

7. Tighten the cap nuts of the cable gland (approx. 4 
Nm).

Figure 7: Terminal clamps of the power supply unit

Caution - Heed the terminal sequence. When clamping 
the connecting line, heed the sequence of the termi-
nals. PE, L3, L2, L1, N.

Reverse polarity of the electrical connecting lines will 
destroy the electronics in the Wallbox!

8. Connect the individual wires of the power supply 
cable as shown in the diagram (Fig. 7). If a singlepha-
se supply voltage is used, it must be connected to L1. 
Terminals L2 and L3 are not used for a single-phase 
connection.

Note: 

This is a tool-free terminal strip. Folding back the 

clamping lever (Fig. 7/1) opens the terminal so that the 
respective individual wire can be inserted. The respec-
tive clamping lever is then shut to secure the respec-
tive individual wire. Folding back more than one clam-
ping lever at a time must be avoided.

Figure 8: Opened electronics housing

Содержание LEO

Страница 1: ...Driving eMobility wallbe Charging station LEO Wallbox INSTALLATION MANUAL 211510 a 09 2020...

Страница 2: ...Safety 4 2 1 Safety instructions 4 2 2 Installation and tests 5 2 3 Protective devices 7 2 4 Operator control elements 7 3 Installation 8 3 1 Prerequisites 8 3 2 Scope of supply Enclosed accessories...

Страница 3: ...te control system The char ging system is intended exclusively for stationary ins tallation The charging system may only be operated and used by persons who have read the operating manual The electric...

Страница 4: ...compatibility regarding radiated interfe rence Should people with a pacemaker PM or implantable cardioverter defibrillator ICD wish to conduct activities on charging systems and their devices in the...

Страница 5: ...he charging system is equipped with integrated AC residual current detection as a convenience function This residual current detection switches off the char ging system at the latest if there is a res...

Страница 6: ...vehicle simulation in accordance with EN 61581 1 The measurements must be carried out with the adapter in the C mode Carry out the mea surements on the measuring sockets of the test adap ter with a su...

Страница 7: ...tion 2 Nameplate The charging system can be operated with a single button LED combination Fig 2 An optional external blocking device e g key switch can be connected to the internal interface Functions...

Страница 8: ...ed by hail or similar Do not expose the Wallbox to direct sunlight because this can cause it to overheat The individual phases of the supply voltage must each be protected with residual current device...

Страница 9: ...and prepare the mounting holes according to the type of mounting surface e g dowels for masonry The screw diameter must not exceed 8 mm 3 Screw in the two top fastening screws Note The fastening scre...

Страница 10: ...e connecting line into the cable gland 7 Tighten the cap nuts of the cable gland approx 4 Nm Figure 7 Terminal clamps of the power supply unit Caution Heed the terminal sequence When clamping the conn...

Страница 11: ...luded in the enclosed accessories 3 6 Commissioning 1 2 Figure 10 wallbe LEO 1 Pushbutton LED combination 2 Nameplate 1 Provide power to the Wallbox Once the Wallbox is connected to the mains the LED...

Страница 12: ...djustable from 6 A to 16 A in 2 A increments Nominal frequency 50 Hz Connection method Spring clip method Charging connection coupler Type 2 Length of charging cable 5 m Operation status infor mation...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...s reserved This document may not be copied in whole or in part or reproduced in any form or form without the written permission of wallbe GmbH All illustrations in this manual are only examples and ma...

Отзывы: