Wallbe LEO Скачать руководство пользователя страница 8

Driving eMobility

8/16

Installation Manual

•  Disconnect the charging system from the power 

supply by switching off the respective circuit brea-
ker in the building.

or

•  Disable the charging system using the optional ex-

ternal blocking device.

Optional external blocking device

If an external blocking device (e.g. key switch) is con-
nected, the charging process is only started when the 
Wallbox has been enabled by the external blocking de-
vice.

 
 

 

3 INSTALLATION

 

3.1   Prerequisites

•  The Wallbox may only be operated when mounted 

vertically.

•  If possible, the Wallbox should be mounted so that 

it is not directly exposed to rain e.g. to prevent icing, 
being damaged by hail or similar. Do not expose the 
Wallbox to direct sunlight because this can cause it 
to overheat.

•  The individual phases of the supply voltage must 

each be protected with residual current devices and 
circuit breakers.

•  No single wires may be used for power supply.

•  The diameter of the supply line must be between 9 

mm and 17 mm.

•  The charging current of the Wallbox must be set in 

accordance with the building‘s circuit breakers. (The 
procedure is described in the „Electrical connection“ 
section.)

 

3.2   Scope of supply/Enclosed accessories

•  Mounting plate with electronics housing,

•  Wallbox housing cover,

•  4x fillister head screws M4x10 (to attach the hou-

sing cover of the Wallbox),

•  Cable gland ESKV25 (cable entry for power supply),

•  Gasket EADR25, for cable gland ESKV25,

•  Device documentation (safety instructions, installa-

tion

•  instructions, operating manual).

 

Содержание LEO

Страница 1: ...Driving eMobility wallbe Charging station LEO Wallbox INSTALLATION MANUAL 211510 a 09 2020...

Страница 2: ...Safety 4 2 1 Safety instructions 4 2 2 Installation and tests 5 2 3 Protective devices 7 2 4 Operator control elements 7 3 Installation 8 3 1 Prerequisites 8 3 2 Scope of supply Enclosed accessories...

Страница 3: ...te control system The char ging system is intended exclusively for stationary ins tallation The charging system may only be operated and used by persons who have read the operating manual The electric...

Страница 4: ...compatibility regarding radiated interfe rence Should people with a pacemaker PM or implantable cardioverter defibrillator ICD wish to conduct activities on charging systems and their devices in the...

Страница 5: ...he charging system is equipped with integrated AC residual current detection as a convenience function This residual current detection switches off the char ging system at the latest if there is a res...

Страница 6: ...vehicle simulation in accordance with EN 61581 1 The measurements must be carried out with the adapter in the C mode Carry out the mea surements on the measuring sockets of the test adap ter with a su...

Страница 7: ...tion 2 Nameplate The charging system can be operated with a single button LED combination Fig 2 An optional external blocking device e g key switch can be connected to the internal interface Functions...

Страница 8: ...ed by hail or similar Do not expose the Wallbox to direct sunlight because this can cause it to overheat The individual phases of the supply voltage must each be protected with residual current device...

Страница 9: ...and prepare the mounting holes according to the type of mounting surface e g dowels for masonry The screw diameter must not exceed 8 mm 3 Screw in the two top fastening screws Note The fastening scre...

Страница 10: ...e connecting line into the cable gland 7 Tighten the cap nuts of the cable gland approx 4 Nm Figure 7 Terminal clamps of the power supply unit Caution Heed the terminal sequence When clamping the conn...

Страница 11: ...luded in the enclosed accessories 3 6 Commissioning 1 2 Figure 10 wallbe LEO 1 Pushbutton LED combination 2 Nameplate 1 Provide power to the Wallbox Once the Wallbox is connected to the mains the LED...

Страница 12: ...djustable from 6 A to 16 A in 2 A increments Nominal frequency 50 Hz Connection method Spring clip method Charging connection coupler Type 2 Length of charging cable 5 m Operation status infor mation...