40D
5 / ENGLISH
490001
6
9
7
8
3
4
5
1
2
J7
272
223
9
8
6
5
3
2
1
J7
4
7
Connections
Make the connections for the heater as shown in the figures below.
Figure 7:
a) Tighten the exhaust gas pipe in place with a hose clamp. The exhaust gas pipe and the heater’s connector
must overlap at least 5 cm.
b) make an opening to the jacket tube for the hose clamp of the exhaust gas pipe.
Figure 8: The pipes of both the
blow and suction duct system are
attached with hose clamps. The
heated extracts the air from the
same end where the power cord
and connectors for fuel and
control panel are.
Figure 9: Connections of the fuel hose, power cord and control panel.
Figure 10: Wiring diagram of the
solenoid valve.
1 Green
2 Empty
3 Pink
4 White
5 Yellow
6 Brown
7 Empty
8 Grey
9 Blue
Brown
Blue
INSTALLATION
Wires in the Info Control Panel
Wires in the Basic Control Panel
1 Green
2 Pink
3 Empty
4 White
5 Yellow
6 Brown
7 Grey
8 Empty
9 Blue
273