Maintenance
Troubleshooting tables
The device does
not do anything.
Check the power cord
connections, joints and the
main switch.
Check the fuses on the circuit
board.
Check the battery voltage.
The battery voltage under
load must be at least
10.7 V
Does the device receive
power?
Measure from the circuit
board's power connector.
Check the control panel and
its cable.
No
Yes
Check the condition of the
battery and the electrical
cables/connectors.
Charge the battery, if
necessary.
Under 10.7 V
LOCKING INDICATION
RELEASING THE LOCK:
1. Switch off the main power as the
lights blink.
2. Switch the main power back on.
3. Press the power switch (for at least 2
s). The yellow current indicator will
light for 1-3 seconds.
4. When the yellow current indicator
light has gone out, press the power
switch again (for at least 2 seconds).
The device is turned off.
5. Restart the device normally.
Check the fuses on the circuit
board.
Undercurrent
FAULT INDICATION WITH
BLINKING LIGHTS
2.0.1_GB