Waldorf RN8110GE Скачать руководство пользователя страница 8

Installation 

Installation Requirements 

NOTE: 



It is most important that this appliance is installed correctly and that operation is correct 
before use.  Installation shall comply with local gas, electrical and health and safety 
requirements. 



This appliance shall be installed with sufficient ventilation to prevent the occurrence of 
unacceptable concentrations of health harmful substances in the room, the appliance is 
installed in. 

 

Waldorf Target Top Range Electric Ovens are designed to provide years of satisfactory service, and correct 

installation is essential to achieve the best performance, efficiency and trouble-free operation. 

This appliance must be installed in accordance with National installation codes and in addition, in 

accordance with relevant National / Local codes covering gas, electrical and fire safety. 

 

Australia: 

- AS5601  

- Gas Installations. 

New Zealand: 

- NZS5261  

- Gas Installation. 

 

Installations must be carried out by authorised persons only.  Failure to install equipment to 

relevant codes and manufacturer’s specifications shown in this section will void the warranty. 

 

Components having adjustments protected (e.g. paint sealed) by the manufacturer are only to 

be adjusted by an authorised service agent. They are not to be adjusted by the installation 

person. 

 

Unpacking 



Remove all packaging and transit protection from appliance including all protective plastic coating 
from exterior stainless steel panels. 



Check equipment and parts for damage.  Report any damage immediately to carrier and distributor. 



Report any deficiencies to distributor who supplied appliance. 



Check available gas and electrical supply is correct to as shown on rating plate located on front right 
hand corner of bottom sill. 

 

Location 

1. 

Installation must allow for a sufficient flow of fresh air for combustion air supply. 

2. 

Installation must include adequate ventilation means, to prevent dangerous build up of combustion 

products. 

3. 

Never directly connect a ventilation system to appliance flue outlet. 

4. 

Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free 
operation.  Minimum installation clearances shown overleaf are to be adhered to. 

5. 

Position appliance in its approximate working position. 

6. 

All air for burner combustion is supplied from beneath appliance.  Legs must always be fitted and no 

obstructions placed on underside or around base of appliance, as obstructions will cause incorrect 

operation and / or failure of appliance. 

7. Components 

having 

adjustments protected (e.g. paint sealed) by manufacturer are only to be 

adjusted by an authorised service agent.  They are not to be adjusted by the installation person. 

 

NOTE:  Do not obstruct or block appliances flue.  Never directly connect a ventilation system to 

appliance flue outlet. 

Combustion Air Requirements: 

 

RN8110GE RN8110GEC 

Natural Gas 12 

m

3

/hr 12 

m

3

/hr 

LPG / Butane 12 

m

3

/hr 12 

m

3

/hr 

Town Gas 

12 m

3

/hr 12 

m

3

/hr 

Содержание RN8110GE

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Target Top Range Electric Ovens Date Purchased Serial Number Dealer Service Provider 232456 10 RN8110GE RN8110GEC RNL8110GE RNL8110GEC...

Страница 2: ...337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free...

Страница 3: ...sions 5 Installation 6 Installation Requirements Unpacking Location Clearances Assembly Rear Rollers Fitting Gas Connection Electrical Connection Commissioning Operation 11 Operation Guide Description...

Страница 4: ...RECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE V...

Страница 5: ...urner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS O...

Страница 6: ...S NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protected agai...

Страница 7: ...5 Dimensions Dimensions RN L 8110GE GEC...

Страница 8: ...g all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distribut...

Страница 9: ...ng instructions Optional Accessories Refer to the Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance from fl...

Страница 10: ...re at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart...

Страница 11: ...nection terminals Refer to Electrical Supply Requirements section for connection details NOTE This appliance can be converted from 3 Phase to Single Phase supply by connecting single phase input to L1...

Страница 12: ...draw and loading for the equipment Refer specification section for correct electrical requirements Check that all the connections are correct and that all cover panels have been re fitted Ensure that...

Страница 13: ...Heating Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Target Top Gas Control Knob OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control OFF Position LOW Posit...

Страница 14: ...be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always se...

Страница 15: ...op heat control to desired setting NOTE When oven top heat control is set to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operati...

Страница 16: ...h back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution...

Страница 17: ...e an approved stainless steel cleaner or stainless steel wool Always rub in direction of grain d Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NO...

Страница 18: ...ion valve is turned On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermocouple has heated Pilot flame too small Gas pressure to...

Страница 19: ...17 Wiring Schematic RN L 8110GE...

Страница 20: ...18 Wiring Schematic RN L 8110GEC...

Страница 21: ...19 Wiring Schematic Wiring Layout for Static Oven Wiring Layout for Convection Oven...

Страница 22: ...ctors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of u...

Страница 23: ...with coloured paint on completion of low fire adjustment Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fix...

Страница 24: ...re burner operating pressure at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is...

Страница 25: ...ector Outer Ring Town Gas 6 30 mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75 kW 750 Ovens 228690 Oven Bo...

Страница 26: ...sion Kits Australia New Zealand Only NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be conv...

Страница 27: ......