Waldorf RN8110GE Скачать руководство пользователя страница 24

22 

Gas Conversion and Specifications 

Gas Type Identification Label 

On completion of the gas conversion, replace gas type identification label, located:- 
 

- At the rear of the unit, above the gas connection. 

 

- Beside the Rating Plate. 

 

Commissioning 

Before leaving the converted installation; 
1. 

Check all gas connections for leakages using soapy water or other gas detecting equipment. 

2. 

Check the following functions in accordance with operating instructions specified in 'Operation'  

section of this manual. 



Light the Pilot Burner. 



Light the Main Burner. 



Check the Low Fire burner operation. 



Check the High Fire burner operation. 



Ensure that all the controls operate correctly. 



Ensure that the operating pressure remains correct 

3. 

Ensure any adjustments done to components that have adjustments / settings sealed (e.g. paint 
sealed) are re-sealed. 

 

NOTE:  If for some reason it is not possible to get appliance to operate correctly, shut ‘Off’ gas  

supply and contact supplier of this appliance. 

 

Gas Specifications 

NOTE: 



(**)  Measure burner operating pressure at target top hob manifold test point with target 
top burner (Inner and outer ring) operating at full setting. 



NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be ad-
justed, apart from when converting between gasses, if required. 



TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas 
regulator supplied.  Town Gas Option is only available with specific ex-factory built 
Town Gas models, which can also be converted to any other gas.  Standard models can 
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas. 



Refer to this section for further details. 

 
 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Warning 

 

Natural Gas 

LP Gas 

Butane 

Town Gas (**) 

Main Burner Injector  (Inner Ring) 

Ø 1.70 mm 

Ø 1.10 mm 

Ø 1.00 mm 

Ø 4.20 mm 

Main Burner Injector  (Outer Ring) 

Ø 2.60 mm 

Ø 1.55 mm 

Ø 1.45 mm 

Ø 6.30 mm 

Pilot Injector 

0.35 

0.25 

0.70 

Burner Aeration Screw X  (Inner) 

25 mm 

25 mm 

20 mm 

Burner Aeration Screw Y (Outer) 

28 mm 

28 mm 

22 mm 

Low Fire Adjustment 

2

1

/

2

 turns out (ccw) 

1 turn out (ccw) 

Blank 

1½ turns out (ccw) 

Operating Pressure 

1.0 kPa (*) 

2.6 kPa (*) 

0.63 kPa (*) 

Gas Regulator Cap Screw 

 

Adjustable Regulator 
(Adjust to Burner  
Operating Pressure  
specified) 

 

Содержание RN8110GE

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Target Top Range Electric Ovens Date Purchased Serial Number Dealer Service Provider 232456 10 RN8110GE RN8110GEC RNL8110GE RNL8110GEC...

Страница 2: ...337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free...

Страница 3: ...sions 5 Installation 6 Installation Requirements Unpacking Location Clearances Assembly Rear Rollers Fitting Gas Connection Electrical Connection Commissioning Operation 11 Operation Guide Description...

Страница 4: ...RECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE V...

Страница 5: ...urner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS O...

Страница 6: ...S NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protected agai...

Страница 7: ...5 Dimensions Dimensions RN L 8110GE GEC...

Страница 8: ...g all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distribut...

Страница 9: ...ng instructions Optional Accessories Refer to the Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance from fl...

Страница 10: ...re at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart...

Страница 11: ...nection terminals Refer to Electrical Supply Requirements section for connection details NOTE This appliance can be converted from 3 Phase to Single Phase supply by connecting single phase input to L1...

Страница 12: ...draw and loading for the equipment Refer specification section for correct electrical requirements Check that all the connections are correct and that all cover panels have been re fitted Ensure that...

Страница 13: ...Heating Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Target Top Gas Control Knob OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control OFF Position LOW Posit...

Страница 14: ...be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always se...

Страница 15: ...op heat control to desired setting NOTE When oven top heat control is set to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operati...

Страница 16: ...h back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution...

Страница 17: ...e an approved stainless steel cleaner or stainless steel wool Always rub in direction of grain d Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NO...

Страница 18: ...ion valve is turned On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermocouple has heated Pilot flame too small Gas pressure to...

Страница 19: ...17 Wiring Schematic RN L 8110GE...

Страница 20: ...18 Wiring Schematic RN L 8110GEC...

Страница 21: ...19 Wiring Schematic Wiring Layout for Static Oven Wiring Layout for Convection Oven...

Страница 22: ...ctors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of u...

Страница 23: ...with coloured paint on completion of low fire adjustment Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fix...

Страница 24: ...re burner operating pressure at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is...

Страница 25: ...ector Outer Ring Town Gas 6 30 mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75 kW 750 Ovens 228690 Oven Bo...

Страница 26: ...sion Kits Australia New Zealand Only NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be conv...

Страница 27: ......

Отзывы: