Waldorf RN8110GE Скачать руководство пользователя страница 2

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in 
writing by the manufacturer. 

 

In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and 
design without prior notice. 

©  Copyright Moffat Ltd.  January 2012. 

MANUFACTURED BY 

 

 

Moffat Limited 

Christchurch 

New Zealand 

 

 

 

INTERNATIONAL CONTACTS 

 

 

AUSTRALIA 

 

Moffat Pty Limited 

E.Mail: [email protected] 

Main Office: 

(tel):  +61 (03) 9518 3888 

 

(fax): +61 (03 9518 3833 

Service: (tel): 

1800 

622 

216 

Spares: (tel): 

1800 

337 

963 

Customer Service: 

(tel): 1800 335 315 

  

(fax): 

1800 

350 

281 

 

 

CANADA 

 

Serve Canada 

Web: www.servecanada.com 

E.Mail: [email protected] 

Sales: 

(tel):  800 551 8795 (Toll Free) 

Service: 

(tel):  800 263 1455 (Toll Free) 

 

 

NEW ZEALAND 

 

Moffat Limited 

Web: www.moffat.co.nz 

E.Mail: [email protected] 

Main Office:

 

(tel): 0800 663328

 

 

 

UNITED KINGDOM 

 

Blue Seal 

Web: www.blue-seal.co.uk 

E.Mail: [email protected] 

Sales: 

(tel):  +44 121 327 5575 

 

(fax): +44 121 327 9711 

Spares: 

(tel):  +44 121 322 6640 

 

(fax): +44 121 327 9201 

Service: 

(tel):  +44 121 322 6644 

 

(fax): +44 121 327 6257 

 

 

UNITED STATES 

 

Moffat 

Web: 

www.moffat.com 

Sales: 

(tel):  800 551 8795 (Toll Free) 

 

(tel):  +1 336 661 1556 

 

(fax): +1 336 661 9546 

Service: 

(tel):  800 858 4477 (Toll Free) 

 

(tel):  +1 366 661 1556 

 

(fax): +1 336 661 1660 

 

 

REST OF WORLD 

 

Moffat Limited 

Web: www.moffat.co.nz 

E.Mail: [email protected] 

Содержание RN8110GE

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Target Top Range Electric Ovens Date Purchased Serial Number Dealer Service Provider 232456 10 RN8110GE RN8110GEC RNL8110GE RNL8110GEC...

Страница 2: ...337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free...

Страница 3: ...sions 5 Installation 6 Installation Requirements Unpacking Location Clearances Assembly Rear Rollers Fitting Gas Connection Electrical Connection Commissioning Operation 11 Operation Guide Description...

Страница 4: ...RECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE V...

Страница 5: ...urner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart from when converting between gasses if required TOWN GAS O...

Страница 6: ...S NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protected agai...

Страница 7: ...5 Dimensions Dimensions RN L 8110GE GEC...

Страница 8: ...g all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distribut...

Страница 9: ...ng instructions Optional Accessories Refer to the Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance from fl...

Страница 10: ...re at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is not to be adjusted apart...

Страница 11: ...nection terminals Refer to Electrical Supply Requirements section for connection details NOTE This appliance can be converted from 3 Phase to Single Phase supply by connecting single phase input to L1...

Страница 12: ...draw and loading for the equipment Refer specification section for correct electrical requirements Check that all the connections are correct and that all cover panels have been re fitted Ensure that...

Страница 13: ...Heating Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Target Top Gas Control Knob OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control OFF Position LOW Posit...

Страница 14: ...be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always se...

Страница 15: ...op heat control to desired setting NOTE When oven top heat control is set to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operati...

Страница 16: ...h back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution...

Страница 17: ...e an approved stainless steel cleaner or stainless steel wool Always rub in direction of grain d Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NO...

Страница 18: ...ion valve is turned On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermocouple has heated Pilot flame too small Gas pressure to...

Страница 19: ...17 Wiring Schematic RN L 8110GE...

Страница 20: ...18 Wiring Schematic RN L 8110GEC...

Страница 21: ...19 Wiring Schematic Wiring Layout for Static Oven Wiring Layout for Convection Oven...

Страница 22: ...ctors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of u...

Страница 23: ...with coloured paint on completion of low fire adjustment Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fix...

Страница 24: ...re burner operating pressure at target top hob manifold test point with target top burner Inner and outer ring operating at full setting NAT LPG Butane Only Operating pressure is ex factory set and is...

Страница 25: ...ector Outer Ring Town Gas 6 30 mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75 kW 750 Ovens 228690 Oven Bo...

Страница 26: ...sion Kits Australia New Zealand Only NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be conv...

Страница 27: ......