10
Installation
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN QUALIFIED
PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1.
Check that the electricity supply is correct as shown
on the Rating Plate attached to the lower front
hand side of the front sill panel.
2.
The supply terminal connections are located at the
rear of the appliance. Refer to ‘Electrical
Connections’ in the ‘Dimensions’ section of the
manual.
3.
Open the oven door and remove the oven control
panel to allow connection access for the electrical
supply.
4.
Connect the mains supply to L1, L2 and L3
connection terminals. Refer to the 'Electrical
Supply Requirements' section for connection
details.
NOTE: This appliance can be converted from 3 Phase
to Single Phase supply by connecting the
single phase input to L1 and adding a bridge
wire between the L1, L2 and L3
connections, (refer to Fig 3 opposite and the
information shown in the 'Electrical Supply
Requirements Table' in the 'Specifications'
Section).
5.
Connect neutral and earth conductors to neutral stud and earth stud respectively.
6.
For all connections ensure that conductors are secure and appropriately terminated.
7.
Tighten the cable gland to secure against tension on the cable.
8.
Check that the polarity of each connection is correct to the mains connection terminals markings on
the appliance.
NOTE:
•
This appliance must be earthed.
•
Fixed wiring installations must incorporate an all-pole disconnection switch.
9.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
10. Connect the power supply to the appliance.
11. Check that the electrical supply is within the input rating specification, refer to the ‘Specifications’
section).
Add bridging
wires between
L1, L2 and L3.
Neutral
supply
connection to
N
Phase
supply
connection to
L1
P
N
Fig 4
WARNING:
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
C
AUTION
:
Changing the supply from 3 phase to single phase will increase the electrical
current loading on the supply cable. Ensure that the supply cable used is of a
sufficient size for the current loading, refer to the 'Electrical Supply
Requirements' in the ‘Specifications’ section.
Содержание GP8910GE
Страница 8: ...6 Dimensions GP L 8910GE GEC GP L 8121GE GEC...
Страница 21: ...19 GP8910GE and GP8121GE Wiring Schematics...
Страница 22: ...20 Wiring Schematics Wiring Diagram GP8910GE GP8121GE...
Страница 23: ...21 GP8910GEC and GP8121GEC Wiring Schematics...
Страница 24: ...22 Wiring Schematics Wiring Diagram GP8910GEC GP8121GEC...
Страница 32: ...30...