Installation Requirements
NOTE:
•
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas, electrical and health and safety
requirements.
•
This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Waldorf Gas Griddle Range Electric Oven are designed to provide years of satisfactory service and
correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical, fire safety and health and safety.
Australia:
- AS5601
- Gas Installations.
New Zealand:
- NZS5261
- Gas Installation.
Australia / New Zealand:
- AS / NZS3000 - Wiring Rules.
United Kingdom:
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
- BS7671
- Requirements for Electrical Installations.
Ireland:
- IS 820
- Non - Domestic Gas Installations.
Installations must be carried out by qualified persons only. Failure to install equipment to the
relevant codes and manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Unpacking
•
Remove all packaging and transit protection from the appliance including all protective plastic
coating from the exterior stainless steel panels.
•
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
•
Ensure that the 4 adjustable feet are fitted with the protruding centre screw.
•
Report any deficiencies to the distributor who supplied the appliance.
•
Check that the available gas supply is correct to that shown on the rating plate located on the front
right hand corner of the bottom sill.
Location
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
Never directly connect a ventilation system to the appliance flue outlet.
4.
Position the appliance in its approximate working position.
5.
All air for burner combustion is supplied from underneath the unit. The legs must always be fitted
and no obstructions placed on the underside or around the base of the appliance, as obstructions
will cause incorrect operation and / or failure of the appliance.
6. Components
having
adjustments
protected (e.g. paint sealed) by manufacturer are only allowed to
be adjusted by an authorised service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to
the appliance flue outlet.
Installation
Combustion Air Requirements:
GP8910GE / GEC
GP8121GE / GEC
Natural Gas
19
m
3
/hr 26
m
3
/hr
LP Gas (Propane)
20 m
3
/hr 27
m
3
/hr
Содержание GP8910GE
Страница 8: ...6 Dimensions GP L 8910GE GEC GP L 8121GE GEC...
Страница 21: ...19 GP8910GE and GP8121GE Wiring Schematics...
Страница 22: ...20 Wiring Schematics Wiring Diagram GP8910GE GP8121GE...
Страница 23: ...21 GP8910GEC and GP8121GEC Wiring Schematics...
Страница 24: ...22 Wiring Schematics Wiring Diagram GP8910GEC GP8121GEC...
Страница 32: ...30...