Wahl HEAT-Prober 392HP Скачать руководство пользователя страница 3

iv

1

TABLE OF CONTENTS (Continued)

8.3

Intrinsically Safe for Hazardous Location
(-S Versions)

17

8.4

Rate of Change with Hot and Cold
Peak Hold (Option R)

18

9.0

THEORY OF OPERATION

19

9.1

General

19

9.2

Program Flow

19

10.0

392M TROUBLE-SHOOTING AID

22

10.1

Scope

22

10.2

Procedure

22

11.0

ACCESSORIES

25

12.0

CALIBRATION SERVICE

26

13.0

THERMISTOR — .01°C RESOLUTION
HEAT PROBER (700M)

27

13.1

General Discussion

27

13.2

Calibration Procedure

29

13.2.1

Equipment Required

29

13.2.2

Calibration

29

14.0

700M TROUBLE-SHOOTING AID

29

15.0

WARRANTY REGISTRATION

32

16.0

RETURN FOR REPAIR/CALIBRATION

32

1.0  INTRODUCTION
The Digital HEAT-Prober

®

is a precision instrument for measuring tempera-

ture. It uses the latest microprocessor technology to provide conformity to
0.1°F to the IEC751 and ITS90 platinum resistance curve. It provides the cer-
tainty of digital display and the precision of 0.1 resolution. It is a complete
instrument with its own rechargeable battery power supply and recharger for
the 392HP, 392E, 392EX, 392M and 392MX, standard 9 volt replaceable bat-
tery for the 392EVX and 392VX and a group of interchangeable probes
designed for rapid and accurate temperature measurement.
The probes and meters are individually calibrated and then tested together in
temperature baths before being sent to the user.

The LED display is 0.33" high with high brightness for good readability in all
light conditions. To minimize power drain, the display is multiplexed. The
LCD display is 0.4" high with excellent contrast.

A large portion of the circuit is designed with low power C-MOS components.
The result is a design which provides a low power drain operation, which
allows operation for 8 hours per charge for the 392E, 392EX, 392M, and
392MX meters. Battery life is 50 hours for the replaceable battery used in the
392EVX and 392VX meters. Continuous operation as well as concurrent bat-
tery charging is possible by utilizing the recharger.

The instrument contains as a standard, the unique Wahl “Maxi Temp” digital
peak hold circuit which gives the user the option to hold the highest tempera-
ture sensed. The peak-hold circuit is achieved by the microprocessor scan-
ning the probe input temperature to determine the peak versus an analog cir-
cuit.

1.1  Qualification Tests
This instrument has been extensively tested under temperature environments
from -40 to +140°F, subject to 4-foot drop test, battery life test and running
life tests.

1.2  Hazardous Location Operation
The instrument is Factory Mutual approved for hazardous location operation
and carries the FM label as standard. Factory Mutual approval as intrinsically
safe for hazardous location operations is in the following categories: Class I
and II, Division I, Group D, F, and G when used with battery pack Part
Number 11681-1. A higher level of approval for Group C, D, E, F, and G is
also available as the -S version, and uses a battery pack, Part Number
11681-2, which contains, in addition, a current limiting fusible resistor.

Содержание HEAT-Prober 392HP

Страница 1: ...rober PLATINUM RTD THERMOMETERS Models 392HP 392E 392E S 392EX 392EX S 392EVX 392M 392M S 392MX 392MX S 392VX 360X and 700M INSTRUCTION MANUAL Copyright 2004 Wahl Instruments Inc Printed in USA W 392...

Страница 2: ...authorized to assume for Wahl any liablility except as set forth above Warranty Temperature Probes and Meter Accessories Wahl warrants its Hand Held Meter Temperature Probes to be free of defects in...

Страница 3: ...in all light conditions To minimize power drain the display is multiplexed The LCD display is 0 4 high with excellent contrast A large portion of the circuit is designed with low power C MOS componen...

Страница 4: ...to conserve battery life 2 1 Meter Operation The HEAT Prober instrument has an accurate measuring range as stated on the front label The probes however may not be capable of this entire range of use...

Страница 5: ...ble of 50 hours continuous operation 2 4 1 Recharging To recharge the batteries use the recharger supplied Plug in directly to 115VAC 60 cycle wall plug and insert jack into socket on left side of HEA...

Страница 6: ...body temperature it requires good contact with that body or in the case of liquids or gases good immersion and mixing A portable probe temperature sensor must have the following characteristics a a l...

Страница 7: ...hane Propane E Metal Dust F Coal Dust and G Grain Dust All 392 Models Available in F C or Dual Scale add F C or D to Model Number Dual Scale not available on S Models 392 SERIES METER SPECIFICATIONS M...

Страница 8: ...gure 5 1 392M Platinum Heat Prober with Wahl Calibrator Model Number CAL392HT 6 0 SET UP AND CALIBRATION 6 1 Equipment Needed A Digital voltmeter Fluke 41 2 digit Model 8600A or equivalent B Wahl Plat...

Страница 9: ...a quick and accurate calibration can be achieved 6 6 1 Setup and Calculations The decade resistor box may be used as the source to perform a standard calibration A coiled cord cable with connector fo...

Страница 10: ...nd 392EVX Models 392HP 392M and 392E Use the Circuit Board Diagrams on these pages to locate potentiometer placement of Zero Adjustment and Span Adjustment Note that placement varies with Model See pa...

Страница 11: ...entire temperature range This also results in superior system accuracies at all temperatures The HP option utilizes a Noise Rejection program which minimizes transient noise effects In this version a...

Страница 12: ...he program Details of the components will be discussed in this section 9 2 Program Flow When Power is turned on the program will start executing instructions from address 000 the location of the top l...

Страница 13: ...age be crammed with new data Additionally if over range is displayed indicating on open probe lead or removed probe conditions are set for the next entry into Gaincheck to cause the compensation readi...

Страница 14: ...58MHz square wave with levels from 0 to 5 volts Replace U6 If still no display go to Step 9 Replace U4 If still no dis play go to Step 7 4 Check voltage at Q4 collector It should be equal to the batte...

Страница 15: ...Return unit to factory for repair NOTE Does not apply to 392MX and 392M with Serial Numbers before N120 11 0 ACCESSORIES 392 SERIES CALIBRATORS Model Number Usable With Meter Calibration Points CAL39...

Страница 16: ...the same as the 392M which is a recharge able nickel cadmium battery pack composed of five AA size cells with a com bined voltage of 6 0 volts and capacity rating of 65 amp hours The unit is supplied...

Страница 17: ...0 plug connector 3 Set resistance to 29 490 ohms and adjust R5 for a display read ing of 0 00 C 32 F 4 Set the decade box to a resistance of 2760 ohms and adjust R13 for a display reading of 60 00 C 1...

Страница 18: ...to next step 8 Measure voltage at pin 6 of wire harness It should be equal to the battery or power supply voltage Proceed to next step Check wire harness for broken wires 9 Replace Q1 and repeat Step...

Страница 19: ...follow up reminders about recalibration dates 16 0 RETURN FOR REPAIR CALIBRATION SERVICE Warranty Repair Information Please contact Wahl Customer Service at 800 421 2853 for a Return Merchandise Auth...