0787-1216
Security
10
Product manual | Version: 1.0.0
Compact Power Supply
DANGER
Observe touch-proof protection when used as a built-in installation device!
As an electrician, ensure that there is adequate protection against accidental contact
when used as a built-in installation device in accordance with DIN 43880 (building instal-
lation).
2.3 Electrical Safety
• High voltage can cause electric shock or burns! Disconnect all power sources from the
product before performing any installation, repair or maintenance.
• Make sure the product does not carry any voltage before starting work.
Power Supply
• Connecting impermissible current or frequency values may destroy the product.
• Provide suitable disconnect and overcurrent protection on the system side. The protec-
tion device must be located near the product where it can be operated. The
OFF
posi-
tion must be clearly marked on the protection device.
Ground / (Lightning) Protection / Fuses
• When handling the product, please ensure that environmental factors (personnel, work
space and packaging) are properly equalized. Do not touch any conducting parts.
• Only operate the product when the ground conductor is connected.
• Protect the product with an appropriate overcurrent protection device.
Lines
• Only use conductor cross-sections sufficient for the current load.
• Observe permissible temperature range of connecting cables.
• Only clamp one conductor to each connection terminal. If several conductors must be
clamped, wire them using an upstream wiring assembly (e.g., WAGO Through Termi-
nal Blocks).
• Use appropriate strain relief.
Protect
• As an electrician, ensure that there is adequate protection against accidental contact
when used as a built-in installation device in accordance with DIN 43880 (building in-
stallation).
2.4 Mechanical Safety
• As the installer of the system, you are responsible for ensuring the necessary touch-
proof protection. Follow the installation guidelines for the specific application.
• The surrounding air temperature for operation indicated in the technical data applies to
the nominal mounting position. Different mounting positions may affect the permissible
surrounding air temperature for operation.
• Cooling of the product must not be impaired. Ensure air can flow freely and that the
minimum clearances from adjacent products/areas are maintained.