![WAGNER PROTEC 95-150 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/wagner/protec-95-150/protec-95-150_original-operating-manual_3220756027.webp)
27
VERSION 01/2020
ORDER NUMBER DOC2340282
IceBreaker 150-300 cm
3
5.5.8 VOLUME FLOW
Wagner AL nozzles
Volume flow* in l/min
Maximum ranges for
continuous operation at
40 DH/min (PROTEC) or
30 DH/min (Tiger)
inch
mm Spray angle
7 MPa
70 bar
1015 psi
10 MPa
100 bar
1450 psi
15 MPa
150 bar
2175 psi
20 MPa
200 bar
2900 psi
0.007
0.18 40°
0.17
0.20
0.21
0.22
0.009
0.23 20-30-40-50-60°
0.21
0.25
0.31
0.36
0.011
0.28 10-20-30-40-50-60°
0.30
0.35
0.43
0.50
0.013
0.33 10-20-30-40-50-60-80°
0.45
0.53
0.62
0.68
0.015
0.38 10-20-30-40-50-60-80°
0.58
0.67
0.81
0.91
0.017
0.43 20-30-40-50-60-70°
0.73
0.79
1.06
1.23
0.019
0.48 20-30-40-50-60-70-80°
0.93
1.09
1.37
1.47
0.021
0.53 20-40-50-60-80°
1.14
1.36
1.69
1.78
0.023
0.58 20-40-50-60-70-80°
1.37
1.59
2.01
2.24
0.025
0.64 20-40-50-60-80°
1.62
1.91
2.40
2.60
0.027
0.69 20-40-50-60-80°
1.83
2.13
2.68
3.12
0.029
0.75 60°
2.19
2.51
3.17
3.63
0.031
0.79 20-40-50-60°
2.40
2.77
3.49
4.00
0.035
0.90 20-40-50-60°
3.22
3.74
4.69
5.14
0.043
1.10 20-50°
5.07
6.04
7.46
7.84
0.052
1.30 50°
5.12
6.10
7.52
8.06
Volume flow refers to water.
5.5.9 PERFORMANCE DIAGRAMS
8 bar
6 bar
4 bar
8 bar
6 bar
4 bar
B_00301
Stroke frequency
/min
Pr
oduc
t pr
essur
e bar (MP
a) psi
A
ir c
onsumption nl/min <sc
fm>
Water flow rate l/min <gpm>
Example diagram