Prima Sprint
.
OPERATING MANUAL
VERSION 07/2009
ORDER NUMBER DOC 2305835
Properties of the characteristic
Field of application/Remarks
Standard level (red)
●
Open-circuit voltage 100 kV
●
Maximum current 120 µA
(current limiting at 120 µA)
●
For poorly rechargeable types of powder.
●
For high powder application.
●
For high application effectiveness.
●
This setting corresponds to the usual
Wagner high-voltage modules and control
units.
Medium level (blue)
●
Open-circuit voltage 100 kV
●
Maximum current 120 µA
●
For small surfaces.
●
For well rechargeable types of powder.
●
For metal powder.
●
To reduce the effects of overcoating
such as craters and orange peel.
●
Increasing
the
open-circuit
voltage
allows for a greater distance between
the spray gun and the workpiece while
maintaining sufficient powder charging.
Soft level (black)
●
Open-circuit voltage 100 kV
●
Maximum current 80 µA
●
For very well rechargeable types of
powder.
●
For small powder application.
●
For post-coatings.