Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
7 Operation
46
Order number 2360922 | Edition 09/2022
6. Screw union nut with attached nozzle guard (9) to the gun body and make sure that the
air cap horns lie in the designated recess (Y).
7. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
Changing from flat jet to round jet
1. Unscrew union nut (9) with air cap (10) and ACF5000 nozzle (11).
2. Remove air cap (10).
3. Press ACF5000 nozzle (11) out of air cap (10) by hand. Thoroughly clean all parts.
4. Insert nozzle screw connection (7) and sealing fitting (8) into nozzle body (6).
5. Screw nozzle nut (5) onto nozzle body (6). Do not screw on nozzle nut completely.
ð
There must be play for the atomizing air between the nozzle nut and the nozzle
body.
6. Screw on nozzle insert (3) using nozzle wrench (4).
7. Screw round jet nozzle attachment (2) with nozzle insert (3) onto spray gun and tighten
by hand.
7.10 REPLACING THE AIRCOAT FLAT JET NOZZLES
B_05755
Y
1
9
10
11
12
1. Switch off control unit.
2. Unscrew union nut completely (12) and remove air cap (10).
3. Remove and clean the ACF 5000 AirCoat nozzle (11).
NOTICE
Defective AirCoat nozzle!
Insufficient paint application quality.
4
Do not use sharp-edged objects on the carbide on the nozzle.
4. Insert new ACF 5000 nozzle (11) into the valve housing.
5. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
6. Screw union nut with attached nozzle guard (9) to the gun body and make sure that the
air cap horns lie in the designated recess (Y).